PubMed Health⌕ Search

Biomedical subjects

Mark H Milman

Publications and source records attributed to Mark H Milman.

2 recordsLinked to original sources

Accurately computing the optical pathlength difference for a michelson interferometer with minimal knowledge of the source spectrum.

Astrometric measurements using stellar interferometry rely on precise measurement of the central white light fringe to accurately obtain the optical pathlength difference of incoming starlight to the two arms of the interferometer. One standard approach to stellar interferometry uses a channeled spectrum to determine phases at a number of different wavelengths that are then converted to the pathlength delay. When throughput is low these channels are broadened to improve the signal-to-noise ratio. Ultimately the ability to use monochromatic models and algorithms in each of the channels to extract phase becomes problematic and knowledge of the spectrum must be incorporated to achieve the accuracies required of the astrometric measurements. To accomplish this an optimization problem is posed to estimate simultaneously the pathlength delay and spectrum of the source. Moreover, the nature of the parameterization of the spectrum that is introduced circumvents the need to solve directly for these parameters so that the optimization problem reduces to a scalar problem in just the pathlength delay variable. A number of examples are given to show the robustness of the approach.

Journal Article↗

Effect of wave-number error on the computation of path-length delay in white-light interferometry.

We analyze the error in computed optical path-length delay when using a phase-shifting interferometry (PSI) algorithm with an error in the operating wavelength. The delay error decomposes into two terms. The first is the error in the conversion from a phase measurement to the delay because of the incorrect wavelength, and the second is the error made in the phase measurement itself that is due to the wavelength error. The most important aspect of this investigation is to ascertain this latter error. A general characterization is obtained, and a particularly simple formula is developed for the special case of least-squares estimation involving only the ratio of the wave-number error to the wave number and a multiplicative factor that is an a priori computable nonlinear function of the ratio of the modulator stroke length to the operating wavelength. Because the ultimate path-length error is a function of the two terms, a new set of PSI algorithms that compensate the computed phase error to cancel the conversion error is developed. Numerical simulations are presented to validate the analysis and establish the insensitivity of the new algorithms to wave-number error.

Journal Article↗