PubMed Health⌕ Search

Biomedical subjects

Mark H Phillips

Publications and source records attributed to Mark H Phillips.

4 recordsLinked to original sources

Application of influence diagrams to prostate intensity-modulated radiation therapy plan selection.

The purpose is to incorporate clinically relevant factors such as patient-specific and dosimetric information as well as data from clinical trials in the decision-making process for the selection of prostate intensity-modulated radiation therapy (IMRT) plans. The approach is to incorporate the decision theoretic concept of an influence diagram into the solution of the multiobjective optimization inverse planning problem. A set of candidate IMRT plans was obtained by varying the importance factors for the planning target volume (PTV) and the organ-at-risk (OAR) in combination with simulated annealing to explore a large part of the solution space. The Pareto set for the PTV and OAR was analysed to demonstrate how the selection of the weighting factors influenced which part of the solution space was explored. An influence diagram based on a Bayesian network with 18 nodes was designed to model the decision process for plan selection. The model possessed nodes for clinical laboratory results, tumour grading, staging information, patient-specific information, dosimetric information, complications and survival statistics from clinical studies. A utility node was utilized for the decision-making process. The influence diagram successfully ranked the plans based on the available information. Sensitivity analyses were used to judge the reasonableness of the diagram and the results. In conclusion, influence diagrams lend themselves well to modelling the decision processes for IMRT plan selection. They provide an excellent means to incorporate the probabilistic nature of data and beliefs into one model. They also provide a means for introducing evidence-based medicine, in the form of results of clinical trials, into the decision-making process.

Aged↗

Evaluation of the new cesium-131 seed for use in low-energy x-ray brachytherapy.

Characterization measurements and calculations were performed on a new medical seed developed by IsoRay Inc. in Richland, Washington, that utilizes the short-lived isotope 131Cs. This model has recently received FDA 510(k) clearance. The objective of this work was to characterize the dosimetric properties of the new seed according to the AAPM Task Group 43 recommendations. Cesium-131 is a low-energy x-ray emitter, with the most prominent peaks in the 29 keV to 34 keV region. The intended application is brachytherapy for treating cancers in prostate, breast, head and neck, lung, and pancreas. The evaluations performed included air-kerma strength, radial dose function, anisotropy in phantom, half-life, energy spectra, and internal activity. The results indicate the CS-1 seeds have a dose-rate constant of 0.915 cGy hr(-1) U(-1) in water, dose penetration characteristics similar to 125I and 103Pd, anisotropy function values on the order of 0.71 at short distances and small angles, and an average anisotropy factor of 0.964. The overall dosimetric characteristics are similar to 125I and 103Pd seeds with the exception of half-life, which is 9.7 days, as compared to 17 days for 103Pd and 60 days for 125I. The shorter half-life may offer significant advantages in biological effectiveness.

Air↗

Random and systematic beam modulator errors in dynamic intensity modulated radiotherapy.

This paper reports on the dosimetric effects of random and systematic modulator errors in delivery of dynamic intensity modulated beams. A sliding-widow type delivery that utilizes a combination of multileaf collimators (MLCs) and backup diaphragms was examined. Gaussian functions with standard deviations ranging from 0.5 to 1.5 mm were used to simulate random positioning errors. A clinical example involving a clival meningioma was chosen with optic chiasm and brain stem as limiting critical structures in the vicinity of the tumour. Dose calculations for different modulator fluctuations were performed, and a quantitative analysis was carried out based on cumulative and differential dose volume histograms for the gross target volume and surrounding critical structures. The study indicated that random modulator errors have a strong tendency to reduce minimum target dose and homogeneity. Furthermore, it was shown that random perturbation of both MLCs and backup diaphragms in the order of sigma = 1 mm can lead to 5% errors in prescribed dose. In comparison, when MLCs or backup diaphragms alone was perturbed, the system was more robust and modulator errors of at least sigma = 1.5 mm were required to cause dose discrepancies greater than 5%. For systematic perturbation, even errors in the order of +/- 0.5 mm were shown to result in significant dosimetric deviations.

Brain Neoplasms↗

Spatial accuracy of fractionated IMRT delivery studies in canine paraspinal irradiation.

Intensity modulated radiation therapy (IMRT) theoretically allows detailed tailoring of the dose distribution in tissue. The goal of this study was to determine if a method of dynamic IMRT could be used to deliver a high dose of radiation to a concave shaped target around the cervical spinal cord. Fifteen young adult dogs from our laboratory population were randomly divided into two groups. A radiation dose of 84 Gy in 4 Gy fractions was delivered with a conventional 4 field technique for Group A dogs, and with dynamic IMRT for Group B dogs to a "C-shaped" target close to the cervical spinal cord. Neurologic status, magnetic resonance imaging results and histopathologic changes were compared among dogs in the two groups. Group A dogs developed myelomalacia with a latency period of 65 +/- 9 days. Group B dogs did not have any histologic changes to the cervical spinal cord when euthanasia was performed 12 months after irradiation. The results demonstrate that this IMRT technique can be safely and precisely delivered to a patient in a clinical situation.

Animals↗