PubMed Health⌕ Search

Biomedical subjects

Mark J Earley

Publications and source records attributed to Mark J Earley.

11 recordsLinked to original sources

Can atrial fibrillation with a coarse electrocardiographic appearance be treated with catheter ablation of the tricuspid valve-inferior vena cava isthmus? Results of a multicentre randomised controlled trial.

OBJECTIVE: To see if strategy of ablating the tricuspid annulus-inferior vena cava isthmus (TV-IVC) is superior to electrical cardioversion to prevent recurrences in patients with coarse atrial fibrillation. DESIGN: Prospective randomised controlled multicentre study. SETTING: Four tertiary referral hospitals in the UK. PATIENTS: 57 patients with persistent coarse atrial fibrillation (irregular P waves > or =0.15 mV in > or =1 ECG lead). INTERVENTIONS: Patients were randomised to receive external cardioversion (group A, n = 30) or TV-IVC ablation +/- DC cardioversion (group B, n = 27). MAIN OUTCOME MEASURES: Cardiac rhythm, scores on quality of life and symptom questionnaires were assessed at 4, 16 and 52 weeks after the procedure. RESULTS: 20 (67%) patients in group A and 19 (70%) patients in group B were in sinus rhythm immediately after their index procedure. At 4, 16 and 52 weeks, the number of patients in sinus rhythm were 5, 3 and 2 in group A and 3, 3 and 1 in group B (p = NS). The quality of life and symptom questionnaire scores were similar in the two groups at each period of follow-up, although they were significantly better for sinus rhythm than for atrial fibrillation at each follow-up visit. CONCLUSIONS: As a first-line strategy, TV-IVC ablation offers no advantages over direct current cardioversion for the management of coarse atrial fibrillation.

Atrial Fibrillation↗

Cryoablation compared with radiofrequency ablation for atrioventricular nodal re-entrant tachycardia: analysis of factors contributing to acute and follow-up outcome.

AIMS: The efficacy of transvenous Cryoablation (Cryo), for the treatment of atrioventricular nodal re-entry tachycardia (AVNRT), when compared with radiofrequency (RF) ablation, requires further investigation. METHODS AND RESULTS: We sought to compare the acute- and follow-up results of 71 cases each of Cryo and RF for AVNRT using a retrospective matched case-control study design and aimed at identifying patient and procedural factors that may predict success with each strategy. Primary failure of Cryo (thus necessitating RF at the same sitting) was seen in 11 (15.4%) cases, whereas there were two (2.8%) primary failures with RF (P<0.01). Patients in the Cryo group had significantly higher arrhythmia recurrence [14 (19.8%)] when compared with the RF group [4 (5.6%)] (P<0.01). The incidence of recurrence following Cryo was significantly higher if an echo beat was still inducible after ablation than if complete slow pathway block was achieved (7/19, vs. 4/46, P<0.001). The median number of Cryo lesions was significantly lower in patients who had recurrence compared with those who did not (1.5 vs. 3.0, P=0.02). CONCLUSION: We have observed a much higher primary failure and recurrence rate with Cryo when compared with RF for AVNRT. It may be possible to decrease this high recurrence rate by aiming to achieve complete slow pathway block and by increasing the number of Cryo lesions.

Adult↗

Successful ablation of atrioventricular nodal reentry tachycardia following the atriopulmonary Fontan procedure.

Arrhythmia is a prevalent complication of the atriopulmonary Fontan procedure, most commonly macro-reentrant tachycardia within the right atrium as a consequence of long-term morphological and haemodynamic changes coupled with surgical intervention. We describe a patient with a long history of supraventricular arrhythmia following the atriopulmonary Fontan procedure identified as atrioventricular nodal reentry tachycardia at electrophysiological assessment. Despite anatomical and technical difficulties related to right atrial morphological changes and loss of the tricuspid annulus with its associated anatomical landmarks, the arrhythmia was successfully ablated using a combined antegrade and retrograde mapping approach.

Adolescent↗

Validation of the noncontact mapping system in the left atrium during permanent atrial fibrillation and sinus rhythm.

OBJECTIVES: The aim of this study was to validate noncontact mapping (NCM) in the left atrium (LA) during sinus rhythm and atrial fibrillation (AF). BACKGROUND: Understanding the mechanisms of AF is crucial to the development of novel and effective treatments. Noncontact mapping records global electrical activation simultaneously and therefore has the potential to elucidate these mechanisms. METHODS: Patients underwent catheter ablation of permanent AF guided by NCM. Virtual and contact unipolar electrograms were recorded simultaneously during sinus rhythm and AF from sites spanning the LA and their morphology, amplitude, and timing were compared. The impact of distance from the array to the endocardial surface and electrogram amplitude were analyzed. RESULTS: A total of 22 patients age 52 +/- 9 (mean +/- SD) years were studied. During sinus rhythm, the median (range) morphology correlation and timing difference between contact and virtual atrial electrograms were 0.81 (0.27 to 0.98) and 4.2 (0 to 18.3) ms, respectively. These results were significantly worse than the corresponding far field individual ventricular electrograms; 0.91 (0.53 to 1.0) and 1.7 (0 to 18.3) ms (p < 0.001). For endocardial sites >40 mm from the array, the correlation was significantly worse than sites <40 mm: 0.73 (0.48 to 0.95) versus 0.87 (0.27 to 0.98) (p < 0.001). The correlation during AF was 0.72 (0.24 to 0.98), which deteriorated with increasing distance from the array. In the presence of adenosine induced atrioventricular block the correlation deteriorated 0.67 +/- 0.16 versus 0.79 +/- 0.11 (p < 0.001). CONCLUSIONS: Noncontact mapping can be performed in human LA; however, the accuracy of reconstructed electrograms is poor >40 mm from the center of the array, particularly during AF. Care must be taken interpreting isopotential maps if the entire endocardial surface of the LA is not close to the array.

Adenosine↗

Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial.

AIMS: To compare the utility of non-fluoroscopic mapping systems (Carto and Ensite NavX) with that of conventional mapping in patients referred for catheter ablation of a wide variety of arrhythmias. METHODS AND RESULTS: Patients referred for catheter ablation (excluding atrial fibrillation, atypical atrial flutter, ventricular tachycardia in structural heart disease, and complete AV nodal ablation) were randomized equally to a procedure guided by Carto, Ensite NavX, or conventional mapping. A total of 145 patients were recruited (82 men, aged 49+/-16, range 18-85). In 19 patients, no ablation was performed, and in the remaining, typical atrial flutter, atrioventricular nodal re-entrant tachycardia, and atrioventricular re-entrant tachycardias [including Wolff-Parkinson-White (WPW)] accounted for 93% of ablations. Overall procedure time, immediate and short-term success, complication rate, and freedom from symptoms at follow-up were identical for all groups. NavX led to the least X-ray exposure: Navx vs. conventional, median (range): 4 (0-50) vs. 13 (2-46) min (P<0.001); NavX vs. Carto, median (range): 4 (0-50) vs. 6 (1-55) min (P=0.008). Both Carto and NavX increased disposable costs by 50% when compared with conventional (P<0.001). For typical atrial flutter, Carto and NavX reduced screening times without increasing procedure cost. If ablation was not performed, NavX was twice as expensive as Carto or conventional. CONCLUSION: Ensite NavX and Carto procedures have similar effectiveness and safety to a conventional approach; however, they both reduce X-ray exposure, with NavX producing a significantly greater effect than Carto. Although this benefit is achieved at a greater financial cost, there may be long-term benefits to catheter laboratory staff.

Arrhythmias, Cardiac↗

Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation.

INTRODUCTION: Accurate visualization of the complex left atrial (LA) anatomy and the location of an ablation catheter within the chamber is important in the success and safety of ablation for atrial fibrillation (AF). We describe the integration of CT into an electroanatomic mapping (EAM) system and its validation in patients undergoing catheter ablation for AF. METHODS AND RESULTS: Thirty patients (59.2 +/- 8 years, 25 M) with paroxysmal (12) and persistent (18) AF underwent ablation using CT image integration into an electroanatomic mapping system. CT registration using the pulmonary veins as markers (landmark) was achieved with an error of 6.4 +/- 2.8 mm with repeat registration required in two patients. Registration of the CT by best fit to a electroanatomic geometry (surface) was achieved with an error of 2.3 +/- 0.4 mm. There was no significant difference in the regional LA registration error at superior (1.7 +/- 0.7 mm), inferior (2.2 +/- 1.4 mm), septal (1.7 +/- 0.8 mm), and lateral (1.7 +/- 0.7 mm, P = 0.13) sites. Cardiac rhythm at the time of CT did not have a significant effect on total or regional surface registration accuracy (mean total 2.5 +/- 0.3 in AF patients vs 2.3 +/- 0.5 in SR patients, P = 0.22). The integrated CT was used to guide the encirclement of the pulmonary veins (PV) in pairs with electrical isolation achieved by maintaining ablation along the ablation line in 58 of 60 PV pairs. Postprocedural PV angiography did not demonstrate significant stenosis. CONCLUSION: CT image integration into an EAM system was successfully performed in patients undergoing catheter ablation for AF. With a greater appreciation of the complex and variable nature of the PV and LA anatomy this new technology may improve the efficacy and safety of the procedure.

Atrial Fibrillation↗

The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation.

BACKGROUND: A detailed appreciation of left atrial/pulmonary vein (LA/PV) anatomy may be important in improving the safety and success of catheter ablation (CA) for atrial fibrillation (AF). OBJECTIVES: The aim of this nonrandomized study was to determine the impact of computerized tomography (CT) image integration into a 3-dimensional (3D) mapping system on the clinical outcome of patients undergoing CA for AF. METHODS: Ninety-four patients (age: 56 +/- 10 years) with AF (paroxysmal 46, persistent 48) underwent wide encirclement of ipsilateral PV pairs using irrigated radiofrequency ablation with the endpoint of electrical isolation. Ablation was guided by 3D mapping alone (electroanatomic 24, noncontact 23) in 47 (3DM group) patients and by CT image integration (Cartomerge) in 47 (CT group). In persistent AF, a combination of linear ablation and targeted ablation of complex fractionated electrograms was also performed. RESULTS: Successful PV electrical isolation did not differ between the two groups. A significant reduction in fluoroscopy times was demonstrated in the CT group (49 +/- 27 minutes vs 3DM group 62 +/- 26 minutes, P = 0.03). Arrhythmia recurrence was reduced in the CT group (32% vs 51% in the 3DM group, P < 0.01). In 30 symptomatic patients (12 CT and 18 3DM), repeat procedures for AF (13 in 3DM and 5 CT, P < or = 0.10) and AT (5 in 3DM and 7 CT, P = NS) were performed. Overall success on 7-day monitor off antiarrhythmic drugs was achieved in 60% in the 3DM group when compared with 83% in the CT group (P < 0.05) at a follow-up of 25 +/- 5 weeks. CONCLUSION: CA for AF guided by CT integration was associated with reduced fluoroscopy times, arrhythmia recurrence, and increased restoration of sinus rhythm. Improved visualization of complex LA geometries might improve the safety and success of CA for AF.

Atrial Fibrillation↗

Catheter inversion: a technique to complete isthmus ablation and cure atrial flutter.

Cure of typical atrial flutter (AFL) by catheter ablation to produce bidirectional block across the tricuspid annulus-inferior vena cava isthmus (IS) is highly effective, but failures may occur. We describe a technique that may allow creation of bidirectional block where a conventional strategy has failed. AFL ablation was performed using the conventional approach with a mapping/ablation (ablation) catheter introduced via the right femoral vein (RFV) to create a line of bidirectional block across the IS. If this was not achieved after five passes of the ablation catheter from the tricuspid annulus to the inferior vena cava (IVC) a catheter inversion technique was used. This allowed stable positioning of the ablation catheter at the IVC end of the isthmus. In 11 patients, a mean of 17 (range 3 to 45) radiofrequency (RF) applications was given before the catheter inversion technique was applied. Following catheter inversion a mean of 4 (1 to 14) further RF applications achieved bidirectional isthmus block in every patient. No complications occurred. Catheter inversion provides a simple, safe, and effective means of achieving bidirectional isthmus conduction block in cases where a conventional ablation strategy might have failed.

Aged↗

Electroanatomic versus fluoroscopic mapping for catheter ablation procedures: a prospective randomized study.

INTRODUCTION: The aim of this prospective randomized study was to compare the routine use of electroanatomic imaging (CARTO) with that of conventional fluoroscopically guided activation mapping (conventional) in an unselected population referred for catheter ablation. We sought to compare the two approaches with respect to procedure outcome and duration, radiation exposure, and cost. METHODS AND RESULTS: All patients undergoing catheter ablation (with the exception of complete AV nodal ablation) were prospectively randomized to either a CARTO or conventional procedure for mapping and ablation. One hundred two patients were randomized. Acute procedural success was similar with either strategy (CARTO vs conventional 43/47 vs 51/55, P > 0.5), as was procedure duration (144 [58] vs 125 [48] min, P = 0.07 (mean [SD]). CARTO was associated with a substantial reduction in fluoroscopy time (9.3 [7.6] vs 28.8 [19.5] min, P < 0.001) and radiation dose (6.2 [6.1] vs 20.8 [32.7] Gray, P = 0.003). CARTO cases used fewer catheters (2.5 [0.7] vs 4.4 [1.1], P < 0.001), but catheter costs were higher (13.8 vs 9.3 units, P < 0.001, where one unit is equivalent to the cost of a nonsteerable quadripolar catheter). CONCLUSION: For all catheter ablation procedures, even when a center's "learning curve" for CARTO is included, procedure duration and outcome are similar for CARTO and conventional procedures. CARTO is associated with drastically reduced fluoroscopy time and radiation dose. Although fewer catheters are used with CARTO, catheter costs remain higher.

Adolescent↗