Mark K Murphy

Publications and source records attributed to Mark K Murphy.

3 recordsLinked to original sources

Technical performance of the Luxel Al(2)O(3):C optically stimulated luminescence dosemeter element at radiation oncology and nuclear accident dose levels.

The dose ranges typical for radiation oncology and nuclear accident dosimetry are on the order of 2-70 Gy and 0.1-5 Gy, respectively. In terms of solid-state passive dosimetry, thermoluminescent (TL) materials historically have been used extensively for these two applications, with silver-halide, leuco-dye and BaFBr:Eu-based films being used on a more limited basis than TL for radiation oncology. This present work provides results on the performance of a film based on an aluminum oxide, Al(2)O(3):C, for these dosimetry applications, using the optically stimulated luminescence (OSL) readout method. There have been few investigations of Al(2)O(3):C performance at radiation oncology and nuclear accident dose levels, and these have included minimal dosimetric and environmental effects information. Based on investigations already published, the authors of this present study determined that overall improvements over film and TLDs for this Al(2)O(3):C OSL technology at radiation oncology and nuclear accident dose levels may include (1) a more tissue-equivalent response to photons compared to X-ray film, (2) higher sensitivity, (3) ability to reread dosemeters and (4) diagnostic capability using small-area imaging. The results of the present investigation indicate that additional favourable performance characteristics for the Al(2)O(3):C dosemeter are a wide dynamic range (0.001-100 Gy), a response insensitive to temperature and moisture over a wide range, negligible dose rate dependence, and minimal change in post-irradiation response. As a radiation detection medium, this OSL phosphor offers an assortment of dosimetry properties that will permit it to compete with current radiation detection technologies such as silver-halide, leuco-dye and photostimulable-phosphor-based films, as well as TLDs.

Aluminum Oxide↗

A variable-energy electron microbeam: a unique modality for targeted low-LET radiation.

We have designed and constructed a low-cost, variable-energy low-LET electron microbeam that uses energetic electrons to mimic radiation damage produced by gamma and X rays. The microbeam can access lower regions of the LET spectrum, similar to conventional X-ray or 60Co gamma-ray sources. The device has two operating modes, as a conventional microbeam targeting single cells or subpopulations of cells or as a pseudo broad-beam source allowing for direct comparison with conventional sources. By varying the incident electron energy, the target cells can be selectively exposed to different parts of the energetic electron tracks, including the track ends.

Electrons↗

Evaluation of the new cesium-131 seed for use in low-energy x-ray brachytherapy.

Characterization measurements and calculations were performed on a new medical seed developed by IsoRay Inc. in Richland, Washington, that utilizes the short-lived isotope 131Cs. This model has recently received FDA 510(k) clearance. The objective of this work was to characterize the dosimetric properties of the new seed according to the AAPM Task Group 43 recommendations. Cesium-131 is a low-energy x-ray emitter, with the most prominent peaks in the 29 keV to 34 keV region. The intended application is brachytherapy for treating cancers in prostate, breast, head and neck, lung, and pancreas. The evaluations performed included air-kerma strength, radial dose function, anisotropy in phantom, half-life, energy spectra, and internal activity. The results indicate the CS-1 seeds have a dose-rate constant of 0.915 cGy hr(-1) U(-1) in water, dose penetration characteristics similar to 125I and 103Pd, anisotropy function values on the order of 0.71 at short distances and small angles, and an average anisotropy factor of 0.964. The overall dosimetric characteristics are similar to 125I and 103Pd seeds with the exception of half-life, which is 9.7 days, as compared to 17 days for 103Pd and 60 days for 125I. The shorter half-life may offer significant advantages in biological effectiveness.

Air↗