Effectiveness of automated external defibrillators in high schools in greater Boston.

A program using a strategy of donating a single automatic external defibrillator to 35 schools in the Boston area resulted in compliance with American Heart Association guidelines on automatic external defibrillator placement and training and 2 successful resuscitations from sudden cardiac arrest. Participating schools indicated a high degree of satisfaction with the program.

Adolescent↗

Association of short-term ambient air pollution concentrations and ventricular arrhythmias.

The authors evaluated the association between ventricular arrhythmias detected by implantable cardioverter defibrillators and ambient air pollution concentrations in the hours immediately before the arrhythmia. Patients given implantable cardioverter defibrillators at the New England Medical Center in Boston, Massachusetts, between mid-1995 and 1999 who lived within 40 km of a central monitoring site (n = 203) were followed until July 2002. The authors used a case-crossover design to study the association between ambient air pollution and up to 798 confirmed ventricular arrhythmias among 84 subjects. The authors found that interquartile range increases in 24-hour moving average particulate matter less than 2.5 mum in aerodynamic diameter and ozone were associated with 19% and 21% increased risks of ventricular arrhythmia, respectively. For each, there was evidence of a linear exposure response, and the associations appeared independent. These associations were stronger than associations with mean concentrations on the same calendar day and previous calendar days. The authors did not find associations with pollutant concentrations less than 24 hours before the arrhythmia. Cases with a prior ventricular arrhythmia within 72 hours had greater risk associated with air pollutants than did cases without a recent arrhythmia. These results confirm previous findings and suggest that matching of pollution periods to arrhythmias is important in detecting such associations.

Aged↗

Extraction of buried P waves from printed electrocardiograms.

BACKGROUND: Morphologic identification of ectopic P-waves from surface ECGs can be challenging, particularly when the P-wave is buried in the QRST wave complex. Because ECGs are often available on paper and not digitally, we developed a method of subtracting the T-wave from the buried P-wave complex on paper ECGs. METHODS: To validate our system, an atrial extrastimulus was introduced during and following the T-wave. The ECGs were scanned and then transformed from an image format to a digital format. A computer algorithm digitally subtracted a QRST with no buried P-wave from one with a buried P-wave, thus resulting in an extracted P-wave. The extracted P-waves were compared to the nonburied P-wave by determining correlation coefficients and by visual grading by two independent reviewers. RESULTS: Visual grading comparing the buried P-wave with the exposed paced P-wave was 94%. The median correlation coefficient was 85%. CONCLUSIONS: An ectopic atrial P-wave obscured by a coincident QRST wave complex can be accurately derived from printed ECG using this PC-based system. Addition of this technique to the existing methods may aid in the localization and ablation of ectopic atrial foci.

Algorithms↗

Device trials in heart failure: a focused summary.

Despite considerable progress in heart failure management with pharmacologic agents, measures to bring about significant improvements in morbidity and mortality are still needed. Cardiac resynchronization therapy (CRT) is a means to enhance myocardial function by stimulating the failing left ventricle at or near the time of right ventricular activation to synchronize ventricular depolarization. Current data from randomized, controlled trials suggest that CRT benefits patients with moderate to severe heart failure and have shown that this therapy significantly reduces mortality and hospital admissions in this group. In addition to CRT, implantable cardioverter-defibrillators have been evaluated in heart failure patients with significantly reduced left ventricular function and have been shown to reduce mortality from sudden cardiac death. This article summarizes recent device trials and discusses how best to apply their results to clinical practice.