Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 Multicenter Phase 2 Trial results).

We hypothesized that assessment of hyperemic myocardial blood flow (MBF) velocity using myocardial contrast echocardiography (MCE) can detect coronary artery disease (CAD). We also postulated that only a single MCE study during stress is required for the detection of CAD in patients with normal function at rest. Patients with known or suspected CAD referred for dipyridamole stress technetium-99m sestamibi single-photon emission computed tomographic (SPECT) studies were enrolled. MCE was performed concurrently with SPECT using continuous infusions of PB127 during intermittent harmonic power Doppler imaging at multiple pulsing intervals. MCE and SPECT were compared in 43 of 54 patients who had adequate studies using both techniques. In 15 of the 43 patients, coronary angiography was performed within 30 days of the MCE/SPECT tests. Overall concordance for classification of patients as normal versus abnormal was 84% (kappa = 0.63) between the 2 tests. When false-negative SPECT scans were corrected for results of angiography, concordance increased to 93% (kappa = 0.82). For territorial analysis, concordance between MCE and SPECT for location of perfusion defects was 65% (kappa = 0.41) and 74% (kappa = 0.61) after SPECT was corrected by angiography. In patients with normal function at rest, a single stress MCE perfusion study allowed identification of CAD with the same concordance as rest/stress perfusion studies. In conclusion, visual assessment of regional differences in MBF velocity using PB127 allows detection of CAD with good concordance compared with technetium-99m sestamibi SPECT. In patients with normal left ventricular function at rest, a single stress PB127 MCE perfusion study is adequate for the detection of CAD.

Adult↗

Myocardial contrast echocardiography (MCE) with triggered ultrasound does not cause premature ventricular complexes: evidence from PB127 MCE studies.

Previous studies suggest that myocardial contrast echocardiography using high mechanical index triggered ultrasound can be associated with increased frequency of the premature ventricular complex (PVC). However, this association has not been systematically examined. PB127 (Point Biomedical Corp, San Carlos, Calif) is a novel microsphere designed for evaluation of myocardial perfusion with ultrasound. PB127 myocardial contrast echocardiography was performed with triggered harmonic power Doppler in early/mid diastole (mechanical index </= 1.0). A total of 71 patients (cohort A) were studied at rest and another 64 (cohort B, age 62 +/- 12.6 years) were allocated to stress. Continuous electrocardigraphy was recorded. The study evaluated premature ventricular complex frequency at baseline, during, and after infusion of PB127 (dose < 0.175 mg/kg, <60-minute duration). Proportions of triggered and nontriggered intervals associated with premature ventricular complex were determined. PVC frequency did not increase with PB127 infusion in either cohort (P =.572, P =.263). Proportion of triggered intervals after QRS associated with PVC was similar to proportion of untriggered intervals in cohort A (P >.999) and was lower than untriggered intervals (P =.001) in B, suggesting that triggers do not cause PVC. PB127 does not cause increase PVC frequency during or after imaging with triggered ultrasound at mechanical index of 1.

Adult↗