PubMed Health⌕ Search

Biomedical subjects

Mark Packer

Publications and source records attributed to Mark Packer.

42 records · Page 3Linked to original sources

Refractive lens exchange with the array multifocal intraocular lens.

PURPOSE: To study the safety and efficacy of refractive lens exchange as a refractive surgery modality in the presbyopic population. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: This retrospective review of patient charts included patient selection, preoperative evaluation, management of astigmatism, surgical technique, postoperative visual outcome, and complications. The study included 68 eyes comprising 32 bilateral and 4 unilateral refractive lens exchanges. RESULTS: All patients having bilateral refractive lens exchange achieved an uncorrected binocular visual acuity of 20/40 and J5 or better 1 to 3 months postoperatively. More than 90% achieved an uncorrected binocular visual acuity of 20/30 and J4 and nearly 60%, of 20/25 and J3. CONCLUSION: Refractive lens exchange was a safe and effective refractive surgery modality in presbyopic patients.

Aged↗

Immersion A-scan compared with partial coherence interferometry: outcomes analysis.

PURPOSE: To compare 2 methods of axial length measurement, immersion ultrasonography and partial coherence interferometry, and to elucidate surgical outcomes based on immersion measurements. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: Axial length measurements in 50 cataractous eyes were obtained by optical biometry (IOLMaster, Zeiss Humphrey Systems) and immersion ultrasound (Axis II, Quantel Medical), and the results were compared. Intraocular lens (IOL) power calculations in the same eyes after cataract extraction and posterior chamber IOL implantation were evaluated retrospectively based on the postoperative spherical equivalent prediction error. RESULTS: Immersion ultrasonography and partial coherence interferometry measurements correlated in a highly positive manner (correlation coefficient = 0.996). Outcomes analysis demonstrated 92.0% of eyes were within +/-0.5 diopter of emmetropia based on immersion axial length measurements. CONCLUSION: Immersion ultrasonography provided highly accurate axial length measurements and permitted highly accurate IOL power calculations.

Biometry↗

Comparison of sonic and ultrasonic phacoemulsification using the Staar Sonic Wave system.

PURPOSE: To compare the performance of sonic phacoemulsification with that of ultrasonic phacoemulsification in regard to 1-day postoperative visual acuity, corneal edema, and procedure efficiency. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: This prospective nonrandomized study comprised 86 eyes with mild to moderate nuclear sclerotic cataract. Forty-three eyes had sonic and 43 ultrasonic phacoemulsification using the Staar Sonic Wave phacoemulsification system. The mean age was 76 years in the ultrasonic group and 71 years in the sonic group. The mean nuclear sclerosis was 2.0+ in the sonic group and 1.9+ in the ultrasonic group. Patient age, lens density, postoperative corneal edema, 1-day postoperative uncorrected visual acuity (UCVA), and the percentage of eyes with a visual acuity of 20/40 or better were determined. In addition, the mean ultrasonic and sonic times, mean percentage phaco power, and mean effective phaco time (EPT) were calculated in each group. RESULTS: Both groups had a 5% incidence of trace corneal edema. The mean UCVA was 20/41 in the ultrasonic group and 20/42 in the sonic group. Seventy-nine percent of eyes in the ultrasonic group and 74% in the sonic group had a UCVA of 20/40. The mean percentage phaco power was 7.2% and 7.6% in the ultrasonic group and sonic group, respectively. The mean EPT was low in both groups, 4.0 and 2.9 seconds, respectively. CONCLUSION: Sonic technology yielded outcomes similar to those of ultrasonic phacoemulsification with respect to postoperative visual acuity and corneal edema in patients with average density nuclear sclerotic cataract.

Corneal Edema↗

New phacoemulsification technologies.

To examine recent developments in the field of phacoemulsification, a literature review was conducted for each system described. the review included peer- reviewed articles, information from manufacturers, and meeting presentations by surgeons. our personal experience with systems we have used forms the underlying basis of our evaluation. data for erbium: YAG laser phacoemulsification came from an interim summary of the U.S. Food and Drug Administration monitored study. Data for NeoSoniX came from a prospective evaluation of phacoemulsification in 25 eyes performed at the Oregon Eye Surgery Center. The development of new technology has allowed safer, more efficient phacoemulsification. Each surgeon should evaluate new developments to achieve the greatest possible benefit for patients.

Animals↗

The Staar Wave.

Explore the source record for details and available documents.

Equipment Design↗

Prospective randomized trial of an anterior surface modified prolate intraocular lens.

PURPOSE: We compare the contrast sensitivity obtained with an anterior surface modified prolate intraocular lens with the contrast sensitivity obtained with a standard spherical intraocular lens. METHODS: Patients presenting for cataract surgery in one eye were randomized to receive either the Tecnis Z9000 intraocular lens (Pharmacia) or the AMO AR40e Opti-Edge intraocular lens (AMO). Sine wave grating contrast sensitivity testing under mesopic and photopic conditions served as the principal outcome measure. RESULTS: The Tecnis Z9000 intraocular lens provided statistically significantly better contrast sensitivity at 1.5 and 3 cycles per degree under mesopic conditions and at 6, 12 and 18 cycles per degree under photopic conditions. CONCLUSION: The use of a modified prolate intraocular lens during cataract surgery has the potential to improve contrast sensitivity under both mesopic and photopic conditions.

Aged↗