PubMed Health⌕ Search

Biomedical subjects

Mark R Smith

Publications and source records attributed to Mark R Smith.

9 recordsLinked to original sources

Circadian and ultradian influences on dreaming: a dual rhythm model.

The dual rhythm model of dreaming states that, under high sensory thresholds, heightened general cortical activation common to both REM/NREM and circadian-driven activation cycles sums to produce the main characteristics of dreaming. In addition, the unique pattern of regional brain activation characteristic of REM sleep amplifies the emotional intensity of the dream. Subjects were awakened from REM and NREM sleep once near the nadir of the core body temperature rhythm, where circadian-driven cortical activation was assumed to be low, and again in the late morning, where this activation was presumed to be high. As predicted, changes in the central characteristics of dream reports mirrored REM/NREM and circadian-driven fluctuations in general activation, while at the same time, the regional activation pattern unique to REM sleep amplified dream emotionality selectively in REM reports.

Activity Cycles↗

A compromise phase position for permanent night shift workers: circadian phase after two night shifts with scheduled sleep and light/dark exposure.

Night shift work is associated with a myriad of health and safety risks. Phase-shifting the circadian clock such that it is more aligned with night work and day sleep is one way to attenuate these risks. However, workers will not be satisfied with complete adaptation to night work if it leaves them misaligned during days off. Therefore, the goal of this set of studies is to produce a compromise phase position in which individuals working night shifts delay their circadian clocks to a position that is more compatible with nighttime work and daytime sleep yet is not incompatible with late nighttime sleep on days off. This is the first in the set of studies describing the magnitude of circadian phase delays that occurs on progressively later days within a series of night shifts interspersed with days off. The series will be ended on various days in order to take a "snapshot" of circadian phase. In this set of studies, subjects sleep from 23:00 to 7:00 h for three weeks. Following this baseline period, there is a series of night shifts (23:00 to 07:00 h) and days off. Experimental subjects receive five 15 min intermittent bright light pulses (approximately 3500 lux; approximately 1100 microW/cm2) once per hour during the night shifts, wear sunglasses that attenuate all visible wavelengths--especially short wavelengths ("blue-blockers")--while traveling home after the shifts, and sleep in the dark (08:30-15:30 h) after each night shift. Control subjects remain in typical dim room light (<50 lux) throughout the night shift, wear sunglasses that do not attenuate as much light, and sleep whenever they want after the night shifts. Circadian phase is determined from the circadian rhythm of melatonin collected during a dim light phase assessment at the beginning and end of each study. The sleepiest time of day, approximated by the body temperature minimum (Tmin), is estimated by adding 7 h to the dim light melatonin onset. In this first study, circadian phase was measured after two night shifts and day sleep periods. The Tmin of the experimental subjects (n=11) was 04:24+/-0.8 h (mean+/-SD) at baseline and 7:36+/-1.4 h after the night shifts. Thus, after two night shifts, the Tmin had not yet delayed into the daytime sleep period, which began at 08:30 h. The Tmin of the control subjects (n=12) was 04:00+/-1.2 h at baseline and drifted to 4:36+/-1.4 h after the night shifts. Thus, two night shifts with a practical pattern of intermittent bright light, the wearing of sunglasses on the way home from night shifts, and a regular sleep period early in the daytime, phase delayed the circadian clock toward the desired compromise phase position for permanent night shift workers. Additional night shifts with bright light pulses and daytime sleep in the dark are expected to displace the sleepiest time of day into the daytime sleep period, improving both nighttime alertness and daytime sleep but not precluding adequate sleep on days off.

Adult↗

Advancing human circadian rhythms with afternoon melatonin and morning intermittent bright light.

CONTEXT: Both light and melatonin can be used to phase shift the human circadian clock, but the phase-advancing effect of the combination has not been extensively investigated. OBJECTIVE: The objective of the study was to determine whether phase advances induced by morning intermittent bright light and a gradually advancing sleep schedule could be increased with afternoon melatonin. PARTICIPANTS: Healthy adults (25 males, 19 females, between the ages of 19 and 45 yr) participated in the study. DESIGN: There were 3 d of a gradually advancing sleep/dark period (wake time 1 h earlier each morning), bright light on awakening [four 30-min bright-light pulses (approximately 5000 lux) alternating with 30 min room light < 60 lux] and afternoon melatonin, either 0.5 or 3.0 mg melatonin timed to induce maximal phase advances, or matching placebo. The dim light melatonin onset was measured before and after the treatment to determine the phase advance. RESULTS: There were significantly larger phase advances with 0.5 mg (2.5 h, n = 16) and 3.0 mg melatonin (2.6 h, n = 13), compared with placebo (1.7 h, n = 15), but there was no difference between the two melatonin doses. Subjects did not experience jet lag-type symptoms during the 3-d treatment CONCLUSIONS: Afternoon melatonin, morning intermittent bright light, and a gradually advancing sleep schedule advanced circadian rhythms almost 1 h/d and thus produced very little circadian misalignment. This treatment could be used in any situation in which people need to phase advance their circadian clock, such as before eastward jet travel or for delayed sleep phase syndrome.

Adult↗

Morning melatonin has limited benefit as a soporific for daytime sleep after night work.

Exogenous melatonin administration in humans is known to exert both chronobiotic (phase shifting) and soporific effects. In a previous study in our lab, young, healthy, subjects worked five consecutive simulated night shifts (23:00 to 07:00 h) and slept during the day (08:30 to 15:30 h). Large phase delays of various magnitudes were produced by the study interventions, which included bright light exposure during the night shifts, as assessed by the dim light melatonin onset (DLMO) before (baseline) and after (final) the five night shifts. Subjects also ingested either 1.8 mg sustained-release melatonin or placebo before daytime sleep. Although melatonin at this time should delay the circadian clock, this previous study found that it did not increase the magnitude of phase delays. To determine whether melatonin had a soporific effect, we controlled the various magnitudes of phase delay produced by the other study interventions. Melatonin (n=18) and placebo (n=18) groups were formed by matching a melatonin participant with a placebo participant that had a similar baseline and final DLMO (+/-1 h). Sleep log measurements of total sleep time (TST) and actigraphic measurements of sleep latency, TST, and three movement indices for the two groups were examined. Although melatonin was associated with small improvements in sleep quality and quantity, the differences were not statistically significant by analysis of variance. However, binomial analysis indicated that melatonin participants were more likely to sleep better than their placebo counterparts on some days with some measures. It was concluded that, the soporific effect of melatonin is small when administered prior to 7 h daytime sleep periods following night shift work.

Adult↗

A procedure for calibration transfer between near-infrared instruments--a worked example using a transmittance single tablet assay for piroxicam in intact tablets.

A procedure was developed for different modes of calibration transfer in near-infrared (NIR) spectroscopy, which included a method for the selection of a subset of samples appropriate for transfer. As a worked example, these guidelines were applied to the transfer of a multivariate calibration model, representing a validated NIR single tablet assay for the active within an intact pharmaceutical product, between three equivalent dispersive NIR transmission instruments. Transfer was first evaluated between two instruments, representing the situation where both were available during calibration development. A spectral correction method alone, applied to the transfer instrument, was not sufficient to facilitate transfer, with further optimisation of the calibration model using a novel wavelength selection algorithm necessary to remove regions of the spectral range that resulted in skewed predictions on the second instrument. Through this approach, a single calibration model was found to be equally accurate and precise on the two instruments. A procedure, using the Kennard-Stone algorithm, is described for determining a reduced number of samples as a transfer set using only the spectral information from the original instrument. The purpose of the subset was to permit transfer to a new instrument where that instrument was not available until after calibration development or where it was undesirable to re-measure the full sample set (i.e. due to excessive reference chemistry). Utilising the transfer set, transfer to a third instrument was evaluated. The calibration model, optimised between the first two instruments, was not directly applicable for the third instrument, with further wavelength selection required to remove a small region of spectral data. On completion, using a full statistical evaluation, a single calibration model was found to be equally accurate and precise on all three instruments.

Anti-Inflammatory Agents, Non-Steroidal↗

Motivation and affect in REM sleep and the mentation reporting process.

Although the emotional and motivational characteristics of dreaming have figured prominently in folk and psychoanalytic conceptions of dream production, emotions have rarely been systematically studied, and motivation, never. Because emotions during sleep lack the somatic components of waking emotions, and they change as the sleeper awakens, their properties are difficult to assess. Recent evidence of limbic system activation during REM sleep suggests a basis in brain architecture for the interaction of motivational and cognitive properties in dreaming. Motivational and emotional content in REM and NREM laboratory mentation reports from 25 participants were compared. Motivational and emotional content was significantly greater in REM than NREM sleep, even after controlling for the greater word count of REM reports.

Adolescent↗

Feasibility study for the rapid determination of the amylose content in starch by near-infrared spectroscopy.

Near-infrared (NIR) spectroscopy was used to determine the amylose content in six different starches, whose declared amylose contents ranged from 2 to 95% m/m. The amylose content of starches can vary considerably between batches depending on growth conditions and time of harvesting. An NIR calibration model was developed for amylose using simple laboratory produced mixtures of amylose and amylopectin in different ratios. The spectral region at 1700-1800nm showed a good correlation to the amylose content of these mixtures. A simple absorbance ratio calibration model using standard normal variate and first derivative pre-treated spectra gave a root mean standard error of prediction of 1.2% m/m. Application to real samples gave amylose contents in reasonable agreement with the average values stated by the supplier. NIR spectroscopy provides a rapid and non-destructive method for the quantitative determination and standardisation of amylose in starch and could make a suitable alternative to traditional techniques, such as complex formation of starch with iodine or n-butanol.

1-Butanol↗

Optimisation of partial least squares regression calibration models in near-infrared spectroscopy: a novel algorithm for wavelength selection.

A novel optimisation algorithm is presented for full spectrum calibration models in near-infrared (NIR) spectroscopy. The algorithm is used to investigate the affect of removing continuous spectral regions on parameters critical to the validity of the model (e.g. explained variance, bias etc.) and ultimately identify and remove problem areas of the spectrum. As an example of its application, this paper shows how to optimise partial least squares regression (PLSR) calibration models for predicting moisture content within an intact pharmaceutical product and how problems due to changes in the nature of samples since setting up the original model may be eliminated. On application of two validated calibration models to a new set of samples unacceptable results were obtained for bias (-0.26 and -0.21% m/m moisture content) between the NIR predicted values and the true values (Karl Fischer analysis). The optimisation algorithm identified small regions of the spectrum, which if included in development of the models contributed significant bias to the final prediction. On removal of these problem regions the calibration models were found to be equally accurate and precise, but with the added advantage of robustness to a variable region of the sample spectrum (bias reduced to -0.05 and -0.09% m/m).

Calibration↗

The transfer between instruments of a reflectance near-infrared assay for paracetamol in intact tablets.

This study compares several correction methods to facilitate the transfer of a validated near-infrared (NIR) assay for paracetamol in intact tablets between two reflectance NIR instruments of the same type. Transfer was defined as the ability to accurately predict the true assay value of a sample measured on a NIR system using an assay developed on a different system, and was assessed using a comprehensive set of statistical tests. Direct electronic transfer of the calibration models, representing the NIR assay, was not possible as a result of a definite residual spectrum between instruments. The use of a correction method based on the standardisation of the material used to record the reference spectrum also proved ineffective. Two methods investigated did succeed, the first employed a response surface calculated between the reflectance values of a set of six certified photometric standards measured on both instruments, with all full range partial least square (PLS) regression models subsequently transferred. The next was correction of the spectra from the second instrument utilising the residual spectrum between the mean sample of the validation set measured on both instruments. Through this approach all PLS regression models and also a single multiple linear regression (MLR) model were transferred. As an outcome of this study guidelines are suggested for the transfer of NIR assays along with the criteria deemed necessary to conclusively prove transfer and justify any correction method utilised. The significant criteria were determined to be the paired t-test with both the UV reference assay data and the original NIR assay data, and comparison of the coefficient of multiple determinations.

Acetaminophen↗