PubMed Health⌕ Search

Biomedical subjects

Mark Taylor

Publications and source records attributed to Mark Taylor.

At least 19 recordsLinked to original sources

Glenohumeral kinematics following total shoulder arthroplasty: a finite element investigation.

The osseous geometry of the glenohumeral joint is naturally nonconforming and minimally constrained, and the joint's stability is maintained by action of the rotator cuff muscles. Damage to these muscles is often associated with joint degeneration, and a variety of glenoid prostheses have been developed to impart varying degrees of stability postoperatively. The issues of conformity and constraint within the artificial shoulder have been addressed through in vivo and in vitro studies, although few computational models have been presented. The current investigation presents the results of three-dimensional finite element analyses of the total shoulder joint and the effects of design parameters upon glenohumeral interaction. Conformity was shown not to influence the loads required to destabilize the joint, although it was the principal factor determining the magnitude of humeral head translation. Constraint was found to correlate linearly with the forces required to dislocate the humeral head, with higher constraint leading to slightly greater humeral migration at the point of joint instability. The model predicts that patients with a dysfunctional supraspinatus would experience frequent eccentric loading of the glenoid, especially in the superior direction, which would likely lead to increased fixation stresses, and hence, a greater chance of loosening. For candidates with an intact rotator cuff, the models developed in this study predict that angular constraints of at least 14 degrees and 6.5 degrees in the superoinferior and anteroposterior axes are required to provide stable unloaded abduction of the humerus, with larger constraints of 18 degrees and 10 degrees necessitated by a dysfunctional supraspinatus. The tools developed during this study can be used to determine the capacity for different implant designs to provide resistance to excessive glenohumeral translations and reduce the potential for instability of the joint, allowing surgeons to optimize postoperative functional gains on a patient by patient basis.

Arthroplasty, Replacement↗

Computational modelling of cell spreading and tissue regeneration in porous scaffolds.

Improved biological and mechanical functionality of musculoskeletal tissue-engineered constructs is required for clinical application, which can only be achieved by comprehensive multidisciplinary research. This review focuses on the contribution of computational modelling as a framework for obtaining an integrated understanding of key processes, which include: nutrient transport and utilization, matrix formation, cell population dynamics, cell attachment and migration, and local cell-cell interactions. Such an integrated perspective of these key aspects will be critical to open up new directions in tissue engineering research, as significant progress can be made by combining existing computational and experimental methods. Furthermore, theoretical modelling has enormous potential in applications ranging from the interpretation of experimental results and the identification of the main governing processes, to the optimization of practical tissue engineering protocols with implications therein for an increasing ageing population.

Animals↗

Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading.

Pre-clinical experimental wear testing of total knee replacement (TKR) components is an invaluable tool for evaluating new implant designs and materials. However, wear testing can be a lengthy and expensive process, and hence parametric studies evaluating the effects of geometric, loading, or alignment perturbations may at times be cost-prohibitive. The objectives of this study were to develop an adaptive FE method capable of simulating wear of a polyethylene tibial insert and to compare predicted kinematics, weight loss due to wear, and wear depth contours to results from a force-controlled experimental knee simulator. Finite element-based computational wear predictions were performed to 5 million gait cycles using both force- and displacement-controlled inputs. The displacement-controlled inputs, by accurately matching the experimental tibiofemoral motion, provided an evaluation of the simple wear theory. The force-controlled inputs provided an evaluation of the overall numerical method by simultaneously predicting both kinematics and wear. Analysis of the predicted wear convergence behavior indicated that 10 iterations, each representing 500,000 gait cycles, were required to achieve numerical accuracy. Using a wear factor estimated from the literature, the predicted kinematics, polyethylene wear contours, and weight loss were in reasonable agreement with the experimental data, particularly for the stance phase of gait. Although further development of the simplified wear theory is important, the initial predictions are encouraging for future use in design phase implant evaluation. In contrast to the experimental testing which occurred over approximately 2 months, computational wear predictions required only 2h.

Arthroplasty, Replacement, Knee↗

Casting votes on healthcare. Midterm election referendums bring big money, potential impact on healthcare-mostly with anti-smoking proposals.

While there are plenty of healthcare-related issues on this year's midterm ballots, Joy Johnson Wilson, left, of the National Conference of State Legislatures, says there were many more that failed to make it. "The cost has gone up to get something on the ballot, and you need an organization to push those measures," she says.

Embryonic Stem Cells↗

Cement mantle fatigue failure in total hip replacement: experimental and computational testing.

One possible loosening mechanism of the femoral component in total hip replacement is fatigue cracking of the cement mantle. A computational method capable of simulating this process may therefore be a useful tool in the preclinical evaluation of prospective implants. In this study, we investigated the ability of a computational method to predict fatigue cracking in experimental models of the implanted femur construct. Experimental specimens were fabricated such that cement mantle visualisation was possible throughout the test. Two different implant surface finishes were considered: grit blasted and polished. Loading was applied to represent level gait for two million cycles. Computational (finite element) models were generated to the same geometry as the experimental specimens, with residual stress and porosity simulated in the cement mantle. Cement fatigue and creep were modelled over a simulated two million cycles. For the polished stem surface finish, the predicted fracture locations in the finite element models closely matched those on the experimental specimens, and the recorded stem displacements were also comparable. For the grit blasted stem surface finish, no cement mantle fractures were predicted by the computational method, which was again in agreement with the experimental results. It was concluded that the computational method was capable of predicting cement mantle fracture and subsequent stem displacement for the structure considered.

Arthroplasty, Replacement, Hip↗

Safety testing of GM-rice expressing PHA-E lectin using a new animal test design.

The 90-day animal study is the core study for the safety assessment of genetically modified foods in the SAFOTEST project. The model compound tested in the 90-day study was a rice variety expressing the kidney bean Phaseolus vulgaris lectin agglutinin E-form (PHA-E lectin). Female Wistar rats were given a nutritionally balanced purified diet with 60% parental rice, 60% PHA-E rice or 60% PHA-E rice spiked with 0.1% recombinant PHA-E lectin for 90 days. This corresponded to a mean daily PHA-E lectin intake of approximately 0, 30 and 100mg/kg body weight for each group, respectively. The spiking was used to increase the specificity and to demonstrate the sensitivity of the study. A range of biological, biochemical, microbiological and pathological parameters were examined and significant differences in weight of small intestine, stomach and pancreas and plasma biochemistry were seen between groups. Included in this paper are also data from the molecular characterisation and chemical analysis of the PHA-E rice, from the construction and production of the PHA-E lectin, and from the preceding 28-day in vivo study where the toxicity of the pure PHA-E lectin was determined. In conclusion, the combined use of information from the compositional analysis, the 28-day study and the characterisation of the PHA-E rice and the PHA-E lectin has improved the design of the 90-day study. The spiking procedure has facilitated the interpretation of the results of the study and transferred it into a valuable tool for the future safety testing of genetically modified foods.

Animals↗