Development of a simulator for radiographic image optimization.

A software package, incorporating two computational patient phantoms, has been developed for optimizing X-ray radiographic imaging. A tomographic phantom, visible photographic Man tomographic phantom (VIP-Man), constructed from Visible Human anatomical color images is used to simulate the scattered portion of an X-ray system using the Electron Gamma Shower National Research Council (EGSnrc) Monte Carlo code. The primary portion of an X-ray image is simulated using the projection ray-tracing method through the Visible Human CT data set. To produce a realistic image, the software simulates quantum noise, blurring effects, lesions, detector absorption efficiency, and other imaging artifacts. The primary and scattered portions of an X-ray chest image are combined to form a final image for future observer studies and image quality analysis. Absorbed doses in organs and tissues of the segmented VIP-Man phantom were also obtained from the Monte Carlo simulations. This paper presents methods of the simulator and preliminary results.

Computers↗

Use of the VIP-Man model to calculate energy imparted and effective dose for x-ray examinations.

A male human tomographic model was used to calculate values of energy imparted (epsilon) and effective dose (E) for monoenergetic photons (30-150 keV) in radiographic examinations. Energy deposition in the organs and tissues of the human phantom were obtained using Monte Carlo simulations. Values of E/epsilon were obtained for three common projections [anterior-posterior (AP), posterior-anterior (PA), and lateral (LAT)] of the head, cervical spine, chest, and abdomen, respectively. For head radiographs, all three projections yielded similar E/epsilon values. At 30 keV, the value of E/epsilon was approximately 1.6 mSv J(-1), which is increased to approximately 7 mSv J(-1) for 150 keV photons. The AP cervical spine was the only projection investigated where the value of E/epsilon decreased with increasing photon energy. Above 70 keV, cervical spine E/epsilon values showed little energy dependence and ranged between approximately 8.5 mSv J(-1) for PA projections and approximately 17 mSv J(-1) for AP projections. The values of E/epsilon for AP chest examinations showed very little variation with photon energy, and had values of approximately 23 mSv J(-1). Values of E/epsilon for PA and LAT chest projections were substantially lower than the AP projections and increased with increasing photon energy. For abdominal radiographs, differences between the PA and LAT projections were very small. All abdomen projections showed an increase in the E/epsilon ratio with increasing photon energy, and reached a maximum value of approximately 13.5 mSv J(-1) for AP projections, and approximately 9.5 mSv J(-1) for PA/lateral projections. These monoenergetic E/epsilon values can generate values of E/epsilon for any x-ray spectrum, and can be used to convert values of energy imparted into effective dose for patients undergoing common head and body radiological examinations.

Adult↗