PubMed Health⌕ Search

Biomedical subjects

Marko K Ivancevic

Publications and source records attributed to Marko K Ivancevic.

9 recordsLinked to original sources

Magnetic resonance imaging with hepatospecific contrast agents in cirrhotic rat livers.

OBJECTIVE: During biliary cirrhosis in rats, organic anion-transporting peptides (Oatps) and ATP-dependent multidrug resistance-associated protein 2 (Mrp2) that are likely to transport the contrast agent Gd-BOPTA through hepatocytes are down-regulated. However, the consequences of such down-regulation on the signal intensity (SI) enhancement are unknown. Consequently, the aim of our study was to measure the hepatic SI enhancement during Gd-BOPTA perfusion as well as the Oatp and Mrp2 expression in normal and cirrhotic livers. MATERIALS AND METHODS: The hepatic SI enhancement during Gd-BOPTA perfusion was measured in livers isolated from normal rats and rats that had a bile duct ligation (BDL) 15, 30, and 60 days before the perfusion. Hepatic injury and transporter expression were measured in control and cirrhotic rats. RESULTS: BDL induced a severe hepatic injury that increased over time with a down-regulation of the transporter expression. The extracellular space (assessed by Gd-DTPA perfusion) increased with the severity of the disease. Gd-BOPTA-induced SI enhancement remained similar in BDL-15 and BDL-30 rats than in control rats but significantly decreased in severe cirrhosis (BDL-60 rats). In comparison, the Mn-DPDP-induced SI enhancement decreases proportionally to the severity of the disease. CONCLUSION: During biliary cirrhosis, Gd-BOPTA-induced SI enhancement could not be related to the hepatic expression of transporters.

ATP-Binding Cassette Transporters↗

Comparison between tagged MRI and standard cine MRI for evaluation of left ventricular ejection fraction.

Global left ventricular function is a prognostic indicator and is used to evaluate therapeutical interventions in patients with heart failure. Regional left ventricular function can be determined with tagged MRI. Assessment of global left ventricular function using the tagging data may have additional clinical value without incurring extra scanning time, which is currently a limiting factor in cardiac imaging. Direct determination of end-diastolic volume is not possible with conventional tagged MRI. However, end-systolic volume can be directly measured because myocardium-blood contrast improves through a tagged image series. We investigated the potential of tagged MRI using frequency-domain analysis software to retrospectively track end-diastolic contour from end-systolic contour and subsequently calculate the ejection fraction. Tagged MRI was compared with the standard bright-blood cine MRI in healthy volunteers ( n=20) and patients with previous myocardial infarction ( n=8). Left ventricular ejection fraction derived from tagged MRI is linearly correlated to left ventricular ejection fraction obtained by standard cardiac cine MRI ( y=1.0 x+1.31, r>0.98, p=0.014). In addition, the inter-observer and intra-observer coefficient of variation for left ventricular ejection fraction measurements was low (CV(intra)=0.4%, CV(inter)=1.3%). With tagged MRI, only end-systolic volume needs to be manually determined, and accurate estimation of left ventricular ejection fraction is obtained because end-diastolic and end-systolic volumes are determined using identical anatomical points. Our data indicate that tagged MRI can be used to quantitatively assess both regional and global left ventricular function. Therefore, tagged MRI may be a valuable clinical tool for determining the prognosis and evaluating the effect of therapeutical intervention using a single imaging session in patients with left ventricular dysfunction.

Humans↗

Hollow fiber bioreactor: new development for the study of contrast agent transport into hepatocytes by magnetic resonance imaging.

The aim of our study was to develop a magnetic resonance (MR)-compatible in vitro model containing freshly isolated rat hepatocytes to study the transport of hepatobiliary contrast agents (CA) by MR imaging (MRI). We set up a perfusion system including a perfusion circuit, a heating device, an oxygenator, and a hollow fiber bioreactor (HFB). The role of the porosity and surface of the hollow fiber (HF) as well as the perfusate flow rate applied on the diffusion of CAs and O2 was determined. Hepatocytes were isolated and injected in the extracapillary space of the HFB (4 x 10(7) cells/mL). The hepatocyte HFB was perfused with an extracellular CA, gadopentetate dimeglumine (Gd-DTPA), and gadobenate dimeglumine (Gd-BOPTA), which also enters into hepatocytes. The HFB was imaged in the MR room using a dynamic T1-weighed sequence. No adsorption of CAs was detected in the perfusion system without hepatocytes. The use of a membrane with a high porosity (0.5 microm) and surface (420 cm2), and a high flow rate perfusion (100 mL/min) resulted in a rapid filling of the HFB with CAs. The cellular viability of hepatocytes in the HFB was greater than 85% and the O2 consumption was maintained over the experimental period. The kinetics of MR signal intensity (SI) clearly showed the different behavior of Gd-BOPTA that enters into hepatocytes and Gd-DTPA that remains extracellular. Thus, these results show that our newly developed in vitro model is an interesting tool to investigate the transport kinetics of hepatobiliary CAs by measuring the MR SI over time.

Animals↗

Comparative study of FAST gradient echo MRI sequences: phantom study.

PURPOSE: To investigate a balanced steady state free precession sequence (b-SSFP) under a large range of conditions and to compare its performance with other types of gradient echo sequences for dynamic imaging. MATERIALS AND METHODS: Balanced turbo field echo (b-TFE; Philips Medical Systems, Best, The Netherlands) was investigated in vitro at a range of T2/T1 along with T1-contrast enhanced turbo field echo (T1-TFE) and turbo field echo (TFE) so that a comparison could be made. Performance was quantified in terms of the initial slope of the signal-to-noise ratio (SNR) vs. 1/T1 curve (sensitivity) and the range of 1/T1 before signal saturation (contrast dynamic range [CDR]). RESULTS: The b-TFE sequence was found to best perform, in terms of an optimal CDR, with a 90 degrees flip angle (FA), saturation preparation, and short inversion time. Using these parameters, the sensitivity was also higher than that of the TFE sequence and T1-TFE sequence under their respective optimal conditions. For detection of small changes in contrast agent concentration (0.0-0.1 mM), b-TFE was also found to be the sequence of choice, with optimized parameters as follows, 90 degrees FA, shortest TR/TE, and no magnetization preparation. The smallest matrices gave the highest signal sensitivity for all three sequences. CONCLUSION: The CDR of b-TFE was much narrower than that of T1-TFE but could be widened under optimized conditions. The sensitivity of the b-TFE technique was the highest of the three sequences under all conditions tested.

Contrast Media↗

Gd-BOPTA transport into rat hepatocytes: pharmacokinetic analysis of dynamic magnetic resonance images using a hollow-fiber bioreactor.

RATIONALE AND OBJECTIVES: To investigate the transport of the hepatobiliary magnetic resonance (MR) imaging contrast agent Gd-BOPTA into rat hepatocytes. MATERIALS AND METHODS: In a MR-compatible hollow-fiber bioreactor containing hepatocytes, MR signal intensity was measured over time during the perfusion of Gd-BOPTA. For comparison, the perfusion of an extracellular contrast agent (Gd-DTPA) was also studied. A compartmental pharmacokinetic model was developed to describe dynamic signal intensity-time curves. RESULTS: The dynamic signal intensity-time curves of the hepatocyte hollow-fiber bioreactor during Gd-BOPTA perfusion were adequately fitted by 2 compartmental models. Modeling permitted to discriminate between the behaviors of the extracellular contrast agent (Gd-DTPA) and the hepatobiliary contrast agent (Gd-BOPTA). It allowed the successfully quantification of the parameters involved in such differences. Gd-BOPTA uptake was saturable at high substrate concentrations. CONCLUSIONS: The transport of Gd-BOPTA into rat hepatocytes was successfully described by compartmental analysis of the signal intensity recorded over time and supported the hypothesis of a transporter-mediated uptake.

Animals↗

Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm.

PURPOSE: To improve the quantification of myocardial perfusion by registering the time series of magnetic resonance (MR) images with injection of gadolinium. MATERIALS AND METHODS: Eight patients underwent MR scans to perform myocardial perfusion exam. Two short axis views of the left ventricle (LV) were acquired in free breathing. Two masks for performing the spatial registration of the images were evaluated. The registration was based on pixel intensity in a multi-resolution scheme. The efficiency of this correction was evaluated by calculating geometric residual displacement of the LV and by fitting the data to a compartment model fit with two parameters: K1, the blood-to-myocardium transfer coefficient, and Vd, the distribution volume of the contrast media. RESULTS: The registration stage allowed a decrease in the observed motion of the LV from more than 1.98 +/- 0.68 mm to less than 0.56 +/- 0.18 mm (mean +/- SD). Variability obtained in the perfusion analysis decreased from 46 +/- 103% to 5+/- 4% for K1 parameter and from 18 +/- 21% to 5 +/- 5% for Vd parameter. CONCLUSION: As with manual correction, this automatic motion correction leads to accurate perfusion parameters in dynamic cardiac MR imaging after contrast agent injection. This automatic stage requires placing only one mask over one frame of the perfusion study instead of manually shifting each image to fit a reference image of the perfusion study.

Algorithms↗

Inflow effect in first-pass cardiac and renal MRI.

PURPOSE: To estimate the effect of the inflow effect on the arterial input function in vivo in cardiac and renal MR perfusion imaging using fast gradient echo (GRE) sequences and contrast media. MATERIALS AND METHODS: The MR exam protocol was designed to acquire images at different phases of the cardiac cycle. The arterial input was thus influenced by various blood flow velocities. RESULTS: It was found that the inflow effect was negligible in the left ventricle of the heart, while it was significantly higher in the aorta for the kidney perfusion measurement. This was principally due to the higher through-the-plane component of the blood flow velocity in the aorta than in the left ventricle. CONCLUSION: The inflow effect can be neglected in the heart cavity, but should be taken into account in renal perfusion.

Aorta↗

Inflow effect correction in fast gradient-echo perfusion imaging.

The purposes of this study were to assess the extent of the inflow effect on signal intensity (SI) for fast gradient-recalled-echo (GRE) sequences used to observe first-pass perfusion, and to develop and validate a correction method for this effect. A phantom experiment with a flow apparatus was performed to determine SI as a function of Gd-DTPA concentration for various velocities. Subsequently a flow-sensitive calibration method was developed, and validated on bolus injections into an open-circuit flow apparatus and in vivo. It is shown that calibration methods based on static phantoms are not appropriate for accurate signal-to-concentration conversion in images affected by high flow. The flow-corrected calibration method presented here can be used to improve the accuracy and robustness of the arterial input function (AIF) determination for tissue perfusion quantification using MRI and contrast media.

Blood Flow Velocity↗

Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging.

OBJECTIVE: The aim of this study was to validate the quantification of absolute renal perfusion (RP) determined by dynamic magnetic resonance imaging (MRI) and contrast media using an experimental model in the rabbit and a transit-timed ultrasound flow probe around the left renal artery as comparison. MATERIAL AND METHODS: An MR-compatible ultrasonic time-of-flight flow-probe was placed around the left renal artery in 9 New Zealand white rabbits. Absolute RP in basal state, after mechanical renal artery stenosis, intravenous dopamine, angiotensin II, or colloid infusion was measured using dynamic MRI and intravenous injection of gadoteridol. The results were correlated to the renal artery flow measured inside the magnet with the transit-timed flow-probe. For the signal intensity concentration conversion, we applied different calibrations according to various velocities measured in the aorta by a phase contrast sequence to correct for inflow effect. MRI-derived RP (in mL/min) was calculated by the maximum upslope method, where RP/volume was defined as the ratio of the cortex contrast enhancement slope over the maximum of the arterial input function determined in the aorta. RESULTS: Reproducible arterial and renal transit curve with excellent contrast to noise ratio were obtained. The MRI derived perfusion was systematically underestimated by comparison to the ultrasonic transit-timed flow-probe but was linearly correlated with these measures (r = 0.80, P < 0.001). CONCLUSIONS: Using a flow-sensitive calibration, an accurate arterial input function can be measured from the blood MR signal and used in a realistic model to assess the RP. There was a good correlation between the MR-derived RP and the renal artery blood flow measured by the flow-meter. This experimental study validates absolute RP quantification by MRI and contrast media injection and justifies further clinical studies.

Animals↗