Knee joint loading differs in individuals with mild compared with moderate medial knee osteoarthritis.

OBJECTIVE: To compare the knee joint loading patterns in individuals with differing radiographic grades of knee osteoarthritis (OA) for characterization of the mechanical implications of different structural states, and to compare the knee adduction angular impulse, a measure of gait complementary to the commonly used peak knee adduction moment. METHODS: Asymptomatic subjects (those without knee OA) having a Kellgren/Lawrence (K/L) radiographic severity grade of 0 or 1 (n = 28) and subjects with symptomatic knee OA having K/L grades of 2 (n = 66) or 3 (n = 23) were recruited. Gait analysis was used to calculate the peak external knee adduction moment and the external knee adduction angular impulse for the whole stance and for the 4 subdivisions of stance. RESULTS: Both the peak knee adduction moment and the knee adduction angular impulse increased with K/L radiographic grade (P < 0.05). However, only the knee adduction angular impulse differed between subjects with moderate (grade 3) and those with mild (grade 2) radiographic knee OA (P < 0.05). CONCLUSION: The differences between mild and moderate symptomatic radiographic knee OA are not only structural but also functional, based on the magnitude of load in the medial knee joint. Moreover, knee adduction angular impulse provides additional information beyond that available from the peak knee adduction moment, and may therefore be an important gait parameter to include in OA research. These findings are important for our understanding of the pathophysiologic mechanisms of OA.

Arthrography↗

Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb.

Due to excellent mechanical properties and good corrosion resistance, titanium-aluminium-vanadium (Ti-6Al-4V) and titanium-aluminium-niobium (Ti-6Al-7Nb) are extensively used for orthopedic surgery. Concern has been voiced concerning the implications of the constituent vanadium in Ti-6Al-4V on the surrounding environment. Particularly in osteosynthesis where the alloys stand in direct contact to skeletal muscle, undesirable biologic reactions may have severe consequences. In a comparative study, we assessed in vivo nutritive perfusion and leukocytic response of striated muscle to the metals Ti-6Al-4V, Ti-6Al-7Nb, and commercially pure titanium (cpTi), thereby drawing conclusions on their short-term inflammatory potential. In 28 hamsters, utilizing the dorsal skinfold chamber preparation and intravital microscopy, we quantified primary and secondary leukocyte-endothelial cell interaction, leukocyte extravasation, microvascular diameter change, and capillary perfusion in collecting and postcapillary venules of skeletal muscle. A manifest discrepancy between the metals concerning impact on local microvascular parameters was not found. All metals induced an only transient and moderate inflammatory response. Only a slight increase in leukocyte recruitment and a more sluggish recuperation of inflammatory parameters in animals treated with Ti-6Al-4V compared to the other two metals suggested a minor, overall not significant discrepancy in biocompatibility. Gross toxicity of bulk Ti-6Al-4V on surrounding tissue could not be found. Conclusively, the commonly used biomaterials Ti-6Al-4V, Ti-6Al-7Nb, and cpTi induce an only transient inflammatory answer of the skeletal muscle microvascular system. Our results indicate that on the microvascular level the tested bulk Ti-alloys and cpTi do not cause adverse biologic reactions in striated muscle.

Alloys↗

Clinical performance of contemporary tibial polyethylene components.

A postclinical retrieval analysis was performed on 43 polyethylene tibial components of a contemporary total knee arthroplasty system with implantation duration between 12 and 80 months. Components were scored for 8 potential modes of surface wear or damage on the top and back surfaces. Moderate backside wear of 4.1 microm/y was documented by measuring the extent of manufacturer's engraved lettering removal. Neither the topside nor backside score correlated with duration of in vivo function. No component experienced topside or backside delamination, cracking, or significant deformation. The greatest contribution to wear and damage score was pitting and scratching secondary to bone cement debris. The extent of both wear and damage experienced by these components was moderate, in comparison with that previously reported with older implant systems.

Arthroplasty, Replacement, Knee↗

Wear particles.

Particulate and ionic debris resulting from in vivo degradation of total joint replacement components are recognized as major factors limiting the longevity of the joint reconstruction and the overall success of the procedure. Particulate and ionic wear and corrosion debris have been associated with a locally aggressive biologic response that can lead to synovitis, periprosthetic bone loss, and aseptic loosening of the implants. Furthermore, concerns exist regarding the systemic dissemination of prosthetic debris, including potential effects resulting from end-organ retention. The long-term success of total disc arthroplasty may well depend, at least in part, on the ability to minimize implant debris generation and the subsequent local and systemic response.

Arthroplasty, Replacement↗

Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb.

The impairment of skeletal muscle microcirculation by a biomaterial may have profound consequences. Due to excellent physical and corrosion characteristics, CoCrMo-, Ti-6Al-4V-, and Ti-6Al-7Nb-alloys are commonly used in orthopedic surgery. Yet concern has been raised with regard to the implications of inevitable corrosion product of these metals on the surrounding biologic environment, particularly in the case of CoCrMo. We, therefore, studied in vivo nutritive perfusion and leukocytic response of striated muscle to these alloys, thereby drawing conclusions on their inflammatory potential. In 28 hamsters, utilizing the dorsal skinfold chamber preparation and intravital microscopy, we could demonstrate that the implant material CoCrMo has a marked impact on local microvascular parameters. While the Ti-alloys Ti-6Al-4V and Ti-6Al-7Nb induced only a transient and moderate inflammatory response, the implantation of a CoCrMo sample led to a distinct and persistent activation of leukocytes combined with disruption of the microvascular endothelial integrity and marked leukocyte extravasation. Animals with Ti-alloys showed a clear tendency of recuperation, while in all but one CoCrMo-treated animals, a breakdown of microcirculation prior to the scheduled end of the experiment was observed. Overall, the alloy Ti-6Al-7Nb was tolerated slightly better than Ti-6Al-4V under the chosen test conditions, though this discrepancy was not statistically significant. Conclusively, the commonly used biomaterials Ti-6Al-7Nb and Ti-6Al-4V induce a considerably lower inflammatory response in the skeletal muscle microvascular system, compared to a CoCrMo-alloy. With a minimum of adverse host reaction, our results indicate that for this particular model Ti-alloys are better tolerated than CoCrMo implant materials.

Alloys↗

The influence of resting periods on friction in the artificial hip.

Insufficient tribologic performance of total joint components is a major cause of prostheses failure. Wear has been studied intensively using testing machines that apply continuous motions. Human locomotion, however, is not well represented by continuous motions alone. Singular events and resting periods are a substantial part of daily activities. Resting does influence adhesion in the artificial joint with possible effects on friction, wear, and loosening. The current study evaluated the effects of resting on the frictional properties of hip prosthesis components. The activity measurements of 32 patients with artificial hip replacements were analyzed for resting durations of the hip. A pin-on-ball screening device was used to determine friction after characteristic resting periods and during continuous oscillating motion. All common articulation pairings were investigated. Prolonged and frequent resting periods of the hip were found for the patients. Initial friction increased with increasing resting duration for all tested materials (between 41% and 191%). The metal-on-metal articulations showed the highest friction level (0.098 for sliding) and the highest increase (191%) in friction with resting duration (0.285 after resting periods of 60 seconds). A high static frictional moment after resting periods might present a risk for aseptic implant loosening. Therefore, large head diameters of metal-on-metal joints should be used with caution, especially when additional unfavorable risk factors such as obesity, weak bone-implant interface, or high activity level are present.

Aged↗

Tribology approach to the engineering and study of articular cartilage.

This study has been based on the assumption that articular motion is an important aspect of mechanotransduction in synovial joints. For this reason a new bioreactor concept, able to reproduce joint kinematics more closely, has been designed. The prototype consists of a rotating scaffold and/or cartilage pin, which is pressed onto an orthogonally rotating ball. By oscillating pin and ball in phase difference, elliptical displacement trajectories are generated that are similar to the motion paths occurring in vivo. Simultaneously, dynamic compression may be applied with a linear actuator, while two-step-motors generate the rotation of pin and ball. The whole apparatus is placed in an incubator. The control station is located outside. Preliminary investigations at the gene expression level demonstrated promising results. Compared with free-swelling control and/or simply compression-loaded samples, chondrocyte-seeded scaffolds as well as nasal cartilage explants exposed to interface motion both showed elevated levels of cartilage oligomeric matrix protein mRNA. The final design of the bioreactor will include four individual stations in line, which will facilitate the investigation of motion-initiated effects at the contacting surfaces in more detail.

Animals↗

Surface motion upregulates superficial zone protein and hyaluronan production in chondrocyte-seeded three-dimensional scaffolds.

A cartilage engineering bioreactor has been developed that provides joint-specific kinematics. This study investigated the effect of articular motion on the gene expression of superficial zone protein (SZP) and hyaluronan synthases (HASs) and on the release of SZP and hyaluronan of chondrocytes seeded onto biodegradable scaffolds. Cylindrical (8 x 4 mm) porous polyurethane scaffolds were seeded with bovine articular chondrocytes and subjected to static or dynamic compression, with and without articulation against a ceramic hip ball. After loading, the mRNA expression of SZP and HASs was analyzed, and SZP immunoreactivity and hyaluronan concentration of conditioned media were determined. Surface motion significantly upregulated the mRNA expression of SZP and HASs. Axial compression alone had no effect on SZP and increased HAS mRNA only at high strain amplitude. SZP was immunodetected only in the media of constructs exposed to surface motion. The release of hyaluronan into the culture medium was significantly enhanced by surface motion. These results indicate that specific stimuli that mimic the kinematics of natural joints, such as articular motion, may promote the development of a functional articular surface-synovial interface.

Animals↗

Chondrocyte gene expression under applied surface motion.

A cartilage bioreactor has been designed that is intended to approximate the kinematics of natural joints and allows for functional cartilage tissue engineering studies. In particular, interface motion can be generated by oscillation of a ball over the surface of a construct. The present study investigated the specific effect of applied articular motion on the gene expression of chondrocytes cultured in 3D scaffolds, with a particular emphasis on different superficial zone protein (SZP)/lubricin transcripts. Cylindrical porous polyurethane scaffolds were seeded with bovine articular chondrocytes and subjected to dynamic compression, with or without articulation against a ceramic hip ball. Articular motion markedly up-regulated the mRNA expression of the four previously described and two newly identified SZP/lubricin isoforms and of cartilage oligomeric matrix protein (COMP), and, to a lesser extent, aggrecan, type II collagen and TIMPs, while axial compression alone had no effect on the chondrocytes' gene expression levels. These results demonstrate the beneficial effect of articular motion not only for stimulation of important lubricating molecules, but also for the preservation of the chondrocytic phenotype.

Animals↗