PubMed Health⌕ Search

Biomedical subjects

Markus Settles

Publications and source records attributed to Markus Settles.

2 recordsLinked to original sources

Comparison between breast volume measurement using 3D surface imaging and classical techniques.

Quantification of the complex breast region can be helpful in breast surgery, which is shaped by subjective influences. However, there is no generally recognized method for breast volume calculation. Three-dimensional (3D) body surface imaging represents a new alternative for breast volume computation. The aim of this work was to compare breast volume calculation with 3D scanning and three classic methods, focusing on relative advantages, disadvantages, and reproducibility. Repeated breast volume calculations of both breasts in six patients (n=12) were performed using a 3D laser scanner, nuclear magnetic resonance imaging (MRI), thermoplastic castings, and anthropomorphic measurements. Mean volumes (cc) and mean measurement deviations were calculated, and regression analyses were performed. MRI showed the highest measurement precision, with a mean deviation (expressed as a percentage of mean breast volume) of 1.56+/-0.52% compared with 2.27+/-0.99% for the 3D scanner, 7.97+/-3.53% for thermoplastic castings, and 6.26+/-1.56% for the anthropomorphic measurements. Breast volume calculations using MRI showed the best agreement with 3D scanning measurement (r=0.990), followed by anthropomorphic measurement (r=0.947), and thermoplastic castings (r=0.727). Compared with three classical methods of breast volume calculation, 3D scanning provides acceptable accuracy for breast volume measurements, better spatial interpretation of the anatomical area to be operated on (due to lack of chest deformation), non-invasiveness, and good patient tolerance. After this preliminary study and further development, we believe that 3D body surface scanning could provide better preoperative planning and postoperative control in everyday clinical practice.

Adult↗

New aspects of breast volume measurement using 3-dimensional surface imaging.

Precise and objective calculation of breast volume is helpful to evaluate the aesthetic result of breast surgery, but traditional methods are unsatisfactory. Three-dimensional (3D) scanning of the body surface allows reproducible and objective assessment of the complex breast region but requires further investigation before clinical application. The main goal of this study was to investigate the precision and accuracy of breast volume measurement using 3D body scanning. Five independent observers standardized the 3D scanning method using 2 dummy models (n = 200) and examined its applicability with 6 test subjects and 10 clinical patients (n = 2220). Breast volume measurements obtained with the 3D-scanner technology were compared with reference measurements obtained from test subjects through nuclear magnetic resonance imaging. The mean deviation of the breast volume measurements of 1 test subject by all observers, expressed as percentage of volume, was 2.86 +/- 0.98, significantly higher than the deviation for the dummy models, 1.65 +/- 0.42 (P < 0.001). With respect to all clinical patients, the mean measurement precision obtained preoperatively was less precise than that obtained postoperatively (3.31 +/- 1.02 versus 1.66 +/- 0.49, respectively). Interobserver differences in measurement precision were not statistically significant. The mean breast volumes obtained by nuclear magnetic resonance imaging (441.42 +/- 137.05 mL) and 3D scanning (452.51 +/- 141.88 mL) significantly correlated (r = 0.995, P < 0.001). Breast volume measurement with 3D surface imaging represents a sufficiently precise and accurate method to guarantee objective and exact recording.

Breast↗