PubMed Health⌕ Search

Biomedical subjects

Marshall S Sussman

Publications and source records attributed to Marshall S Sussman.

9 recordsLinked to original sources

Characterizing coronary motion and its effect on MR coronary angiography--initial experience.

PURPOSE: To characterize coronary artery motion as a prescan procedure to select the optimum scan setting that will produce high-resolution images. MATERIALS AND METHODS: A 2D real-time scan was used to image the major coronary arteries during breath-holding and free-breathing conditions. With the use of the 2D images, motion displacement of each artery was measured along three axes. Motion data obtained from a computer simulation were used to estimate point-spread functions (PSFs) associated with different high-resolution spiral acquisition strategies, including real-time, cardiac-gated, and respiratory-gated acquisitions. The simulation output determined the optimum acquisition and scan parameters that would produce the highest-spatial-resolution images of the coronary arteries. The effects of heart rate (HR), extended breath-holding, and number of slices per heart cycle were also investigated. RESULTS: Substantial variations in coronary motion occur among individuals, which directly influences the optimum parameters for a high-resolution scan. Lower HRs and longer breath-holds yield substantially increased spatial resolution. The maximum number of slices per heart cycle can also be determined to minimize slice-to-slice distortion. CONCLUSION: The results suggest that to obtain high-resolution coronary images, one should perform a prescan coronary-motion characterization for each individual so that the scan parameters can be optimized before data acquisition.

Computer Simulation↗

Cartilage T2 assessment: differentiation of normal hyaline cartilage and reparative tissue after arthroscopic cartilage repair in equine subjects.

PURPOSE: To prospectively assess T2 mapping characteristics of normal articular cartilage and of cartilage at sites of arthroscopic repair, including comparison with histologic results and collagen organization assessed at polarized light microscopy (PLM). MATERIALS AND METHODS: Study protocol was compliant with the Canadian Council on Animal Care Guidelines and approved by the institutional animal care committee. Arthroscopic osteochondral autograft transplantation (OAT) and microfracture arthroplasty (MFx) were performed in knees of 10 equine subjects (seven female, three male; age range, 3-5 years). A site of arthroscopically normal cartilage was documented in each joint as a control site. Joints were harvested at 12 (n = 5) and 24 (n = 5) weeks postoperatively and were imaged at 1.5-T magnetic resonance (MR) with a 10-echo sagittal fast spin-echo acquisition. T2 maps of each site (21 OAT harvest, 10 MFx, 12 OAT plug, and 10 control sites) were calculated with linear least-squares curve fitting. Cartilage T2 maps were qualitatively graded as "organized" (normal transition of low-to-high T2 signal from deep to superficial cartilage zones) or "disorganized." Quantitative mean T2 values were calculated for deep, middle, and superficial cartilage at each location. Results were compared with histologic and PLM assessments by using kappa analysis. RESULTS: T2 maps were qualitatively graded as organized at 20 of 53 sites and as disorganized at 33 sites. Perfect agreement was seen between organized T2 and histologic findings of hyaline cartilage and between disorganized T2 and histologic findings of fibrous reparative tissue (kappa = 1.0). Strong agreement was seen between organized T2 and normal PLM findings and between disorganized T2 and abnormal PLM findings (kappa = .92). Quantitative assessment of the deep, middle, and superficial cartilage, respectively, showed mean T2 values of 53.3, 58.6, and 54.9 msec at reparative fibrous tissue sites and 40.7, 53.6, and 61.6 msec at hyaline cartilage sites. A significant trend of increasing T2 values (from deep to superficial) was found in hyaline cartilage (P < .01). Fibrous tissue sites had no significant change with depth (P > .59). CONCLUSION: Qualitative and quantitative T2 mapping helped differentiate hyaline cartilage from reparative fibrocartilage after cartilage repair at 1.5-T MR imaging.

Animals↗

A lesion stabilization method for coronary angiography.

A method to make a coronary artery segment of interest appear stationary when viewing a sequence of angiographic images is proposed. The purpose of this method is to facilitate the assessment of lesions caused by coronary artery disease by improving detectability. A description of the stabilization algorithm based on template matching is given. Stabilization was performed on 41 clinical coronary angiograms exhibiting various stenoses and was successful in 39/41 cases. A quantitative analysis of stabilization errors was performed by introducing simulated moving vessels of decreasing contrast into sequences of clinical images.

Algorithms↗

Real-time magnetic resonance with physiologic monitoring for improved scan localization.

Imaging of the coronary arteries at diagnostic resolutions is made difficult due to cardiac and respiratory motion during data acquisition. Cardiac gating and respiratory gating or breath holding are effective ways to reduce the effects of motion. The optimal cardiac and respiratory timings vary widely across individuals. This work presents a real-time magnetic resonance imaging approach with physiologic monitoring that can be used to predict the optimal timings on a subject-by-subject basis during a brief real-time prescan. The feasibility of this approach at determining the optimal cardiac trigger delay and respiratory phase is demonstrated.

Adult↗

Pulsatile motion effects on 3D magnetic resonance angiography: implications for evaluating carotid artery stenoses.

In-plane carotid artery motion during a 3D MR angiography (MRA) scan can significantly degrade the resulting image resolution. This study characterizes the effect of cardiac pulsatility on 3D contrast-enhanced (CE) MRA with elliptical centric acquisitions using a point-spread function (PSF) analysis. Internal carotid artery (ICA) motion was collected from volunteers and patients using both MR and ultrasound (US) scans. After measuring the carotid artery motion displacement, a simulation was performed which calculated the blurring effects for three different protocols: nongated and two different cardiac gating schemes. The motion sensitivity of each protocol was evaluated for different spatial resolutions. The selection of optimal imaging parameters for a given scan time was investigated. The final results showed that cardiac-gated acquisitions only over a limited region of k-space high spatial frequencies are more time-efficient than cardiac gating for the entire k-space, as it allows for higher resolutions to be achieved and for capturing the arterial phase with low spatial frequencies. Selecting the optimal gating parameters depends directly on the motion characteristics of each individual. Our initial clinical experience is presented, and the need for a real-time tool that characterizes motion behavior for each individual as a prescan protocol is discussed.

Carotid Arteries↗

Adaptive averaging for improved SNR in real-time coronary artery MRI.

A technique has been developed for combining a series of low signal-to-noise ratio (SNR) real-time magnetic resonance (MR) images to produce composite images with high SNR and minimal artifact in the presence of motion. The main challenge is identifying a set of real-time images with sufficiently small systematic differences to avoid introducing significant artifact into the composite image. To accomplish this task, one must: 1) identify images identical within the limits of noise; 2) detect systematic errors within such images with sufficient sensitivity. These steps are achieved by evaluating the correlation coefficient (CC) between regions in prospective images and a template containing the anatomy of interest. Images identical within noise are selected by comparing the measured CC values to the theoretical distribution expected due to noise. Sensitivity for systematic error depends on the SNR of the CC (=SNR(CCmax)), which in turn depends on the noise, and the template size and structure. By varying the template size, SNR(CCmax) may be altered. Experiments on phantoms and coronary artery images demonstrate that the SNR(CCmax) necessary to avoid introducing significant artifact varies with the target composite SNR. The future potential of this technique is demonstrated on high-resolution (approximately 0.9 mm), reduced field-of-view real-time coronary images.

Algorithms↗

Optimized spiral imaging for measurement of myocardial T2 relaxation.

Microcirculation oxygen levels and blood volumes should be reflected in measurements of myocardial T(2) relaxation. This work describes the optimization of a spiral imaging strategy for robust myocardial T(2) measurement to minimize the standard deviation of T(2) measurement (sigmaT(2)). Theoretical and experimental studies of blurring at muscle/blood interfaces enabled the derivation of parameter sets which reduce sigma T(2) to the level of 5%. T(2) relaxation mapping within healthy volunteers provided estimation of residual sigmaT(2) within the optimized technique. The standard deviation in T(2) measurement across regions of interest (ROIs) in different locations is about 9%. The standard deviation in T(2) measurement in an ROI across different time points is about 5%.

Humans↗

Factors affecting the correlation coefficient template matching algorithm with application to real-time 2-D coronary artery MR imaging.

This paper characterizes factors affecting the accuracy of the correlation coefficient (CC) template matching algorithm, as applied to motion tracking from two-dimensional real-time coronary artery magnetic resonance images. The performance of this algorithm is analyzed in the presence of both random and systematic error. In the presence of random error, it is shown that a necessary and sufficient condition for accurate motion tracking is a large CC difference-to-noise ratio (CCDNR). The CCDNR itself is in turn affected by five factors: image and template size, image and template structure, and the magnitude of the noise. Techniques are introduced for manipulating some of these factors in order to increase the CCDNR for greater motion tracking accuracy. In the presence of superimposed systematic error it is shown that, while large CCDNR is necessary, it alone is not sufficient to ensure accurate motion tracking. Techniques are developed for improving motion tracking accuracy that minimize the effects of systematic error, while maintaining an adequate CCDNR level. The ability of these techniques to improve motion tracking accuracy is demonstrated both in phantoms and in coronary artery images.

Algorithms↗

Variable-density adaptive imaging for high-resolution coronary artery MRI.

Variable-density (VD) spiral k-space acquisitions are used to acquire high-resolution (0.78 mm), motion-compensated images of the coronary arteries. Unlike conventional methods, information for motion compensation is obtained directly from the coronary anatomy itself. Specifically, periods of minimal coronary distortion are identified by applying the correlation coefficient template matching algorithm to real-time images generated from the inner, high-density portions of the VD spirals. Combining the data associated with these images together, high-resolution, motion-compensated coronary images are generated. Because coronary motion is visualized directly, the need for cardiac-triggering, breath-holding, and navigator echoes is eliminated. The motion compensation capability of the technique is determined by the inner-spiral spatial and temporal resolution. Results indicate that the best performance is achieved using inner-spiral images with high spatial resolution (1.6-2.9 mm), even though temporal resolution (four to six independent frames per second) suffers as a result. Image quality within the template region in healthy volunteers was found to be comparable to that achieved with cardiac-triggered breath-hold scans, although extended acquisition times of around 5 min were needed to overcome reduced SNR efficiency.

Algorithms↗