PubMed Health⌕ Search

Biomedical subjects

Marta Paiusco

Publications and source records attributed to Marta Paiusco.

4 recordsLinked to original sources

Testing of the analytical anisotropic algorithm for photon dose calculation.

The analytical anisotropic algorithm (AAA) was implemented in the Eclipse (Varian Medical Systems) treatment planning system to replace the single pencil beam (SPB) algorithm for the calculation of dose distributions for photon beams. AAA was developed to improve the dose calculation accuracy, especially in heterogeneous media. The total dose deposition is calculated as the superposition of the dose deposited by two photon sources (primary and secondary) and by an electron contamination source. The photon dose is calculated as a three-dimensional convolution of Monte-Carlo precalculated scatter kernels, scaled according to the electron density matrix. For the configuration of AAA, an optimization algorithm determines the parameters characterizing the multiple source model by optimizing the agreement between the calculated and measured depth dose curves and profiles for the basic beam data. We have combined the acceptance tests obtained in three different departments for 6, 15, and 18 MV photon beams. The accuracy of AAA was tested for different field sizes (symmetric and asymmetric) for open fields, wedged fields, and static and dynamic multileaf collimation fields. Depth dose behavior at different source-to-phantom distances was investigated. Measurements were performed on homogeneous, water equivalent phantoms, on simple phantoms containing cork inhomogeneities, and on the thorax of an anthropomorphic phantom. Comparisons were made among measurements, AAA, and SPB calculations. The optimization procedure for the configuration of the algorithm was successful in reproducing the basic beam data with an overall accuracy of 3%, 1 mm in the build-up region, and 1%, 1 mm elsewhere. Testing of the algorithm in more clinical setups showed comparable results for depth dose curves, profiles, and monitor units of symmetric open and wedged beams below dmax. The electron contamination model was found to be suboptimal to model the dose around dmax, especially for physical wedges at smaller source to phantom distances. For the asymmetric field verification, absolute dose difference of up to 4% were observed for the most extreme asymmetries. Compared to the SPB, the penumbra modeling is considerably improved (1%, 1 mm). At the interface between solid water and cork, profiles show a better agreement with AAA. Depth dose curves in the cork are substantially better with AAA than with SPB. Improvements are more pronounced for 18 MV than for 6 MV. Point dose measurements in the thoracic phantom are mostly within 5%. In general, we can conclude that, compared to SPB, AAA improves the accuracy of dose calculations. Particular progress was made with respect to the penumbra and low dose regions. In heterogeneous materials, improvements are substantial and more pronounced for high (18 MV) than for low (6 MV) energies.

Algorithms↗

IMRT treatment planning:- a comparative inter-system and inter-centre planning exercise of the ESTRO QUASIMODO group.

BACKGROUND AND PURPOSE: The purpose of this work was a comparison of realistic IMRT plans based on the same CT-image data set and a common predefined set of dose objectives for the planning target volume and the organs at risk. This work was part of the larger European QUASIMODO IMRT verification project. MATERIALS AND METHODS: Eleven IMRT plans were produced by nine different European groups, each applying a representative set of clinically used IMRT treatment planning systems. The plans produced were to be deliverable in a clinically acceptable treatment time with the local technical equipment. All plans were characterized using a set of different quality measures such as dose-volume histograms, number of monitor units and treatment time. RESULTS: Only one plan was able to fulfil all dose objectives strictly; six plans failed some of the objectives but were still considered to be clinically acceptable; four plans were not able to reach the objectives. Additional quality scores such as the number of monitor units and treatment time showed large variations, which mainly depend on the delivery technique. CONCLUSION: The presented planning study showed that with nearly all presently available IMRT planning and delivery systems comparable dose distributions could be achieved if the planning goals are clearly defined in advance.

Anthropometry↗

Inverse and forward optimization of one- and two-dimensional intensity-modulated radiation therapy-based treatment of concave-shaped planning target volumes: the case of prostate cancer.

BACKGROUND: Intensity-modulated radiation therapy (IMRT) was suggested as a suitable technique to protect the rectal wall, while maintaining a satisfactory planning target volume (PTV) irradiation in the case of high-dose radiotherapy of prostate cancer. However, up to now, few investigations tried to estimate the expected benefit with respect to conventional three-dimensional (3D) conformal radiotherapy (CRT). PURPOSE: Estimating the expected clinical gain coming from both 1D and 2D IMRT against 3DCRT, in the case of prostate cancer by mean of radiobiological models. In order to enhance the impact of IMRT, the case of concave-shaped PTV including prostate and seminal vesicles (P+SV) was considered. MATERIALS AND METHODS: Five patients with concave-shaped PTV including P+SV were selected. Two different sets of constraints were applied during planning: in the first one a quite large inhomogeneity of the dose distribution within the PTV was accepted (set (a)); in the other set (set (b)) a greater homogeneity was required. Tumor control probability (TCP) and normal tissue control probability (NTCP) indices were calculated through the Webb-Nahum and the Lyman-Kutcher models, respectively. Considering a dose interval from 64.8 to 100.8 Gy, the value giving a 5% NTCP for the rectum was found (D(NTCP(rectum)=5%)) using two different methods, and the corresponding TCP(NTCP(rectum)=5%) and NTCP(NTCP(rectum)=5%) for the other critical structures were derived. With the first method, the inverse optimization of the plans was performed just at a fixed 75.6 Gy ICRU dose; with the second method (applied to 2/5 patients) inverse treatment plannings were re-optimized at many dose levels (from 64.8 to 108 Gy with 3.6 Gy intervals). In this case, three different values of alpha/beta (10, 3, 1.5)were used for TCP calculation. The 3DCRT plan consisted of a 3-fields technique; in the IMRT plans, five equi-spaced beams were applied. The Helios Inverse Planning software from Varian was used for both the 2D IMRT and the 1D IMRT inverse optimization, the last one being performed fixing only one available pair of leaves for modulation. A previously proposed forward 1D IMRT 'class solution' technique was also considered, keeping the same irradiation geometry of the inversely optimized IMRT techniques. RESULTS: With the first method, the average gains in TCP(NTCP(rectum)=5%) of the 2D IMRT technique, with respect 3DCRT, were 10.3 and 7.8%, depending on the choice of the DVHs constraints during the inverse optimization procedure (set (a) and set (b), respectively). The average gain (DeltaTCP(NTCP(rectum)=5%)) coming from the inverse 1D IMRT optimization was 5.0%, when fixing the set (b) DVHs constraints. Concerning the forward 1D IMRT optimization, the average gain in TCP(NTCP(rectum)=5%) was 4.5%. The gain was found to be correlated with the degree of overlapping between rectum and PTV. When comparing 2D IMRT and 1D IMRT, in the case of the more realistic set (b) constraints, DeltaTCP(NTCP(rectum)=5%) was always less than 3%, excepting one patient with a very large overlap region. Basing our choice on this result, the second method was applied to this patient and one of the remaining. Through the inverse re-optimization of the treatment plans at each dose level, the gain in TCP(NTCP(rectum)=5%) of the inverse 2D technique was significantly higher than the ones obtained by applying the first method (concerning the two patients: +6.1% and +2.4%), while no significant benefit was found for inverse 1D. The impact of changing the alpha/beta ratio was less evident in the patient with the lower gain in TCP(NTCP(rectum)=5%). CONCLUSIONS: The expected benefit due to IMRT with respect to 3DCRT seems to be relevant when the overlap between PTV and rectum is high. Moreover, the difference between the inverse 2D and the simpler inverse or forward 1D IMRT techniques resulted in being relatively modest, with the exception of one patient, having a very large overlap between rectum and PTV. Optimizing the inverse planning at each dose level to find TCP(NTCP(rectum)=5%)e level to find TCP(NTCP(rectum)=5%) can improve the performances of inverse 2D IMRT, against a significant increase of the time for planning. These results suggest the importance of selecting the patients that could have significant benefit from the application of IMRT.

Dose-Response Relationship, Radiation↗

Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: experience from five radiotherapy departments.

BACKGROUND AND PURPOSE: An increasing number of radiotherapy centres is now aiming for clinical implementation of intensity modulated radiotherapy (IMRT), but--in contrast to conventional treatment--no national or international guidelines for commissioning of the treatment planning system (TPS) and acceptance tests of treatment equipment have yet been developed. This paper bundles the experience of five radiotherapy departments that have introduced IMRT into their clinical routine. METHODS AND MATERIALS: The five radiotherapy departments are using similar configurations since they adopted the commercially available Varian solution for IMRT, regarding treatment planning as well as treatment delivery. All are using the sliding window technique. Different approaches towards the derivation of the multileaf collimator (MLC) parameters required for the configuration of the TPS are described. A description of the quality control procedures for the dynamic MLC, including their respective frequencies, is given. For the acceptance of the TPS for IMRT multiple quality control plans were developed on a variety of phantoms, testing the flexibility of the inverse planning modules to produce the desired dose pattern as well as assessing the accuracy of the dose calculation. Regarding patient treatment verification, all five centres perform dosimetric pre-treatment verification of the treatment fields, be it on a single field or on a total plan procedure. During the actual treatment, the primary focus is on patient positioning rather than dosimetry. Intracavitary in vivo measurements were performed in special cases. RESULT AND CONCLUSION: The configurational MLC parameters obtained through different methods are not identical for all centres, but the observed variations have shown to be of no significant clinical relevance. The quality control (QC) procedures for the dMLC have not detected any discrepancies since their initiation, demonstrating the reliability of the MLC controller. The development of geometrically simple QC plans to test the inverse planning, the dynamic MLC modules and the final dose calculation has proven to be useful in pointing out the need to remodel the single pencil beam scatter kernels in some centres. The final correspondence between calculated and measured dose was found to be satisfactory by all centres, for QC test plans as well as for pre-treatment verification of clinical IMRT fields. An intercomparison of the man hours needed per patient plan verification reveals a substantial variation depending on the type of measurements performed.

Humans↗