Separation of microcystins by capillary electrochromatography in monolithic columns.

Contribution on microcystin variant analysis by capillary electrochromatography (CEC) with easily affordable spectrophotometric detection is presented. Two types of reversed-phase capillary columns formed by inorganic or organic polymer monoliths were prepared for this purpose. The analyses were performed isocratically by means of tris(hydroxymethyl) aminomethane (TRIS) buffers of mildly alkaline pH containing 30% (v/v) acetonitrile as the mobile phases. The samples were injected electrokinetically and the analyses were done at the same separation field strength of 500 V/cm. Microcystins were detected at 238 nm. Although both column types differ not only in monolith quality (inorganic versus organic) but also in the length of the aliphatic moiety (C8 versus C12) similar results were achieved. The on-column preconcentration as the encouraging prospect of electrochromatographic technique was also tested. Consequently 5% of column volume was injected in contrast with 0.5% at standard injection scheme resulting in the six times enrichment of the low concentrated cyanobacterial extract at the top of the separation column. From these preliminary results can be seen that the CEC method is fully applicable for rapid microcystin screening.

Chromatography, High Pressure Liquid↗

Sample injection in capillary electrochromatography by heart-cut technique.

The splitter working in heart-cut regime was used for sample injection in capillary electrochromatography. The principle was implemented in an automated microgradient system allowing to inject from microlitre down to nanolitre volumes with high repeatability and minimal extra-column band broadening. The apparatus is able to deliver discrete volumes of liquids at a preset volumetric flow rate and to stop and restore the flow at any moment. This brings a high degree of liquid manipulation flexibility. An extremely low split ratio is sufficient during the analysis, which saves mobile phase consumption substantially. The key parameters influencing the function of the heart-cut splitter were characterised. The function of the apparatus was demonstrated under isocratic, preconcentration and gradient capillary electrochromatography separation conditions. In all cases the statistic evaluation of the main parameters was performed, showing that high repeatability of retention times, peak heights and areas was achieved.

Automation↗