PubMed Health⌕ Search

Biomedical subjects

Martin G Stoel

Publications and source records attributed to Martin G Stoel.

6 recordsLinked to original sources

Relation between lipoprotein(a) and fibrinogen and serial intravascular ultrasound plaque progression in left main coronary arteries.

OBJECTIVES: Patients with elevated lipoprotein(a) [Lp(a)] and fibrinogen levels have an increased risk of coronary heart disease and adverse cardiovascular events. There is evidence that coronary plaque progression is linked to a higher risk for future cardiovascular events. BACKGROUND: There are no data demonstrating a relation between Lp(a), fibrinogen, and directly measured coronary plaque progression over time. METHODS: We performed a retrospective analysis of serial intravascular ultrasound (IVUS) studies of 60 left main stems (18 +/- 9 months apart) to evaluate plaque progression in relation to Lp(a) and fibrinogen levels and association with adverse cardiovascular events. RESULTS: There was a positive correlation between Lp(a) (r = 0.58; p < 0.0001), fibrinogen (r = 0.48; p < 0.0001), and changes in plaque-plus-media area. Patients with plaque progression (n = 41) had higher Lp(a) (30 +/- 26 mg/dl vs. 14 +/- 9 mg/dl; p < 0.0012) and fibrinogen (295 +/- 88 mg/dl vs. 240 +/- 72 mg/dl; p = 0.019) levels than patients with plaque regression (n = 19). Multivariate linear regression analysis showed Log Lp(a) (regression coefficient = 9.45; p = 0.0008) but not fibrinogen to be independently associated with plaque progression. A total of 19 patients suffered from adverse cardiovascular events; they had higher Lp(a) (44 +/- 30 mg/dl vs. 16 +/- 12 mg/dl; p < 0.0001) and fibrinogen (342 +/- 73 mg/dl vs. 248 +/- 76 mg/dl; p < 0.0001) levels. Multivariate logistic regression analysis showed Log Lp(a) (odds ratio 10.20, 95% confidence interval 2.36 to 44.13; p = 0.0019) and fibrinogen (odds ratio 1.01, 95% confidence interval 1.00 to 1.03; p = 0.018) were independently associated with adverse cardiovascular events. CONCLUSIONS: Serial IVUS showed a positive correlation between Lp(a) and fibrinogen levels and plaque progression. Lp(a), but not fibrinogen, remains independently associated with plaque progression. In addition, the present data suggest a considerable incremental value of Lp(a) in predicting cardiovascular risk.

Aged↗

Dedicated calibration formulas permit correction of differences between measurements by different IVUS devices as demonstrated in atherosclerotic human coronary arteries in vitro.

Serial intravascular ultrasound (IVUS) measurements of coronary vessel dimensions are major endpoints of studies focusing on pharmacological interventions, efficiency of drug eluting stents, and vascular remodeling. In serial studies measurement variability among different IVUS devices may cause substantial misinterpretation and error. We analyzed 33 human coronary plaques in vitro using two different IVUS systems (mechanical IVUS system with a 40 MHz Atlantis SR catheter; solid-state electronic IVUS system with a 20 MHz Invision catheter) and repeatedly measured the total vessel, lumen, and plaque + media cross-sectional area and plaque burden (plaque + media area divided by total vessel area). Between the "raw" measurements made by the two devices, there was a significant difference for both plaque + media area (2.35+/-1.86 mm(2), P < 0.01) and plaque burden (5.39+/-3.68%, P < 0.05). Measurements were then corrected by use of recently introduced calibration formulas; as a result the differences decreased significantly for all IVUS parameters measured ( P < 0.0001). After correction, the remaining differences between the corrected mechanical and solid-state IVUS measurements similar to differences between repeated measurements with the same IVUS device (i.e., the intraobserver variability). Thus, in serial studies the use of different IVUS devices at index and follow-up procedure may introduce a substantial error as a result of system-related differences. The application of dedicated calibration formulas allows for correction for these differences by decreasing such differences to the level of intraobserver variability.

Aged↗

Remodeling index compared to actual vascular remodeling in atherosclerotic left main coronary arteries as assessed with long-term (> or =12 months) serial intravascular ultrasound.

OBJECTIVES: We present the remodeling index (RI) versus serial intravascular ultrasound (IVUS) data. BACKGROUND: The RI, derived by comparing lesion external elastic membrane (EEM) cross-sectional area versus the reference at one time point, is used in various IVUS studies as a substitute of true remodeling (change in EEM over time), assuming that it represents true remodeling. METHODS: We studied 46 non-stenotic left main arteries using serial IVUS (follow-up 18 +/- 8 months). Plaques were divided into subgroups according to the follow-up RI: follow-up RI >1 (n = 27) versus follow-up RI < or =1 (n = 19). RESULTS: Lesions with a follow-up RI >1 had an increase in lumen despite an increase in plaque because of an increase in EEM. Conversely, lesions with a follow-up RI < or =1 had a reduction in lumen as a result of both a plaque increase and EEM decrease. Overall, the follow-up RI correlated directly with changes in lesion site EEM (baseline-to-follow-up). Although there was no correlation between the follow-up RI and changes in reference EEM area, changes in reference EEM area did correlate directly with changes in lesion EEM area. In nearly 90% of lesions with a follow-up RI >1, there was a previously documented increase in EEM area. Using multivariate linear regression analysis, the follow-up RI was dependent on the baseline RI, the increase in lesion EEM area, and the decrease in reference EEM area. The follow-up RI was not dependent on changes in lesion plaque area. CONCLUSIONS: The vast majority of left main lesions with a remodeling index >1 had evidence of a previous increase in lesion-site EEM area.

Aged↗

Early identification of left ventricular remodelling after myocardial infarction, assessed by transthoracic 3D echocardiography.

AIMS: The usefulness of 3D echocardiography (3DE) for accurate evaluation of left ventricular (LV) remodelling after acute myocardial infarction (AMI), and early identification of remodelling in the subacute phase, was assessed. METHODS AND RESULTS: Thirty-three AMI patients (21 anterior AMIs) underwent 3DE prospectively at baseline (6+/-4 days) and at 3, 6, and 12 months post-AMI. Remodelling was defined as >20% increase in end-diastolic volume (EDV) at 6 or 12 months in relation to baseline. In patients with remodelling (n = 13) at baseline, EDV and end-systolic volume (ESV), but not ejection fraction (EF), were significantly increased compared to patients without subsequent remodelling (n = 20). At 12 months, EDV and ESV increased further and significantly, and EF was unchanged in patients with remodelling, whilst LV volumes were unchanged and EF slightly increased in patients without remodelling. Clinical, electrocardiographic, and echocardiographic variables were analysed for the early identification of LV remodelling. Of these, at baseline the 3D sphericity index (EDV divided by the volume of a sphere, the diameter of which is the LV major end-diastolic long axis) was, by far, the most predictive variable with a sensitivity, specificity, and positive and negative predictive value for a cutoff value of >0.25 of 100%, 90%, 87% and 100%, respectively. CONCLUSIONS: Three-dimensional echocardiography can differentiate patients with and without subsequent development of LV remodelling accurately and early on the basis of the 3D sphericity index, a new and highly predictive variable.

Adult↗

Frame count reserve.

BACKGROUND: The Doppler wire-derived (relative) coronary flow velocity reserve (CVR) that is used to evaluate functional significance of a coronary stenosis is a method performed only by interventional cardiologists. An angiographic method would be useful in the diagnostic catheterization laboratory. For this purpose, we investigated the relation between TIMI frame count reserve (FCR) and CVR. METHODS AND RESULTS: In 38 patients, (relative) FCR of left anterior descending (LAD) and left circumflex coronary artery (LCx) was calculated by using manual, synchronized contrast agent injections and compared with (relative) CVR. In addition, vessel length was measured with an intracoronary guidewire and frame count flow velocity was calculated and compared with average peak velocity. There was a strong correlation between FCR and CVR (r=0.62, P<0.001) and between relative FCR and relative CVR (r=0.84, P<0.001). The LAD was significantly longer than the LCx (mean, 14.3+/-1.6 cm versus 11.4+/-1.8 cm, P<0.001), and, therefore, TIMI frame count of LAD was significantly higher than of LCx (mean basal 32.5+/-15.1 versus 23.6+/-9.1 and hyperemic 12.1+/-6.6 versus 8.7+/-3.2, both P<0.02). However, all flow velocity measurements and estimations of volume flow were not different for LAD compared with LCx. There were also no differences between mean FCR and CVR of LAD or LCx, of both vessels compared with each other and between mean relative FCR and relative CVR. CONCLUSIONS: The (relative) frame count reserve can be used to estimate (relative) coronary flow velocity reserve.

Adenosine↗

Magnetic resonance imaging versus Doppler guide wire in the assessment of coronary flow reserve in patients with coronary artery disease.

BACKGROUND: Coronary flow velocity reserve (CFVR), defined as the ratio of maximal hyperaemic to baseline flow velocity, has been validated as a marker of physiological significance of a coronary lesion. Clinically, this parameter is measured invasively during X-ray angiography using the Doppler guide wire. With magnetic resonance (MR) imaging it is possible to quantify CFVR non-invasively. DESIGN: The purpose of the study was to compare CFVR, acquired with MR imaging and the Doppler guide wire in patients with coronary artery disease. METHODS: Twenty-two patients suffering from one- or two-vessel coronary artery disease as derived from diagnostic X-ray coronary angiography were included. Coronary flow velocity reserve was measured at baseline and during maximal hyperaemia, obtained by intravenous administration of adenosine using MR phase contrast velocity quantification. Within 2 weeks CFVR was measured invasively with a Doppler guide wire. RESULTS: In 26 coronary arteries CFVR was acquired with both techniques. Mean CFVR in the stenosed and healthy reference arteries was 1.5 +/- 0.7 and 2.7 +/- 1.0 (P < 0.01) respectively for MR measurements and 1.9 +/- 0.7 and 3.1 +/- 0.6 (P < 0.01) respectively for Doppler measurements. Bland-Altman analysis revealed a non-significant mean difference between the two techniques of 0.4 +/- 1.2. CONCLUSION: In a selected group of stable patients with coronary artery disease MR flow velocity quantification provides non-invasive data equivalent to the invasive Doppler guide wire data. Variability in both the MR and Doppler ultrasound measurement resulted in a significant scatter of data without systematic difference.

Blood Flow Velocity↗