PubMed Health⌕ Search

Biomedical subjects

Martin H Hoffmann

Publications and source records attributed to Martin H Hoffmann.

3 recordsLinked to original sources

Multidetector-row computed tomography for noninvasive coronary imaging.

Computed tomography (CT) permits cross-sectional imaging of the heart. Temporal and spatial resolutions of the technique have been insufficient to cover the heart without motion artefacts until the recent advent of multidetector systems with more than 16 detector rows. The modality is now suited for noninvasive imaging of the coronary arteries, producing detailed morphologic images of the entire coronary tree with upto 0.4 mm of spatial resolution, within a single short breath-hold duration. CT imaging goes beyond the delineation of the coronary lumen as provided by selective invasive angiography; the plaque burden of the coronary artery wall can be visualized directly, utilizing soft-tissue contrast and a high sensitivity even for the small calcifications that are present in hard plaque formations. Therefore, CT combines elements of catheterization angiography for lumen imaging and of intravascular ultrasound imaging for coronary wall imaging. However current CT technology is not yet able to compete with the temporal or spatial resolution of catheterization angiography nor does it provide the detailed spatial or contrast resolution of intravascular ultrasound imaging. At present, its use is therefore restricted to complementing the invasive modalities in appropriate indications. Although CT entails significantly less risk than the invasive procedures, the risks of radiation dose exposure and contrast agent application are not negligible. In the foreseeable future, if the current rate of technological advancement continues, CT may replace the invasive modalities in routine care for diagnostic purposes.

Calcium↗

Synergy of MDCT and cine MRI for the evaluation of cardiac motility.

OBJECTIVE: The objective of our study was to validate the feasibility of the synergistic use of cardiac MR and CT data sets for ventricular motility analysis and to correlate measurement variability with underlying heart rate. SUBJECTS AND METHODS: Twenty patients underwent concurrent ECG-gated MDCT and MRI for evaluation of ventricular motility, expressed as ventricular wall thickening and motion. Initially, individual measurement repetition series were analyzed by determining intraobserver variability and detecting intraobserver bias related to heart rates. Subsequently, absolute measurement differences of CT or MR data were statistically evaluated. Finally, absolute measurement differences were correlated with underlying heart rates by curve estimation regression. RESULTS: Analysis of measurement reproducibility proved that data variability was dependent on only the anatomic localization of the analyzed ventricular segment, not on the imaging technique used or underlying heart rate, in normofrequent patients. Comparing MR and CT image data sets, no statistically significant differences were identified when ventricular motility was evaluated based on data sets of either imaging technique in normofrequent patients. Tachycardic frequencies, above 100 beats per minute, led to exponential error propagation due to insufficient temporal resolution of the current CT technology. CONCLUSION: This study proved that cardiac motility assessment based on ECG-gated CT and MR data sets resulted in comparable ventricular function results for normofrequent patients; however, the high spatial resolution of cardiac MDCT cannot compensate for the lack of temporal resolution in patients with tachycardia, thus emphasizing the necessity of reporting ventricular motility analysis results in combination with heart rate to allow consideration of this possible cause for measurement variation.

Adolescent↗

Spectral coronary multidetector computed tomography angiography: dual benefit by facilitating plaque characterization and enhancing lumen depiction.

OBJECTIVE: To assess ex vivo specimens of atherosclerotic coronary arteries by dual energy (DE) multidetector computed tomography (MDCT) imaging, and to correlate depicted vessel lumen morphology and detected tissue characteristics with histopathologic analysis. METHODS: Coronary arteries were imaged on a 16-slice MDCT using a DE protocol consisting of a 90- and 140-kV scan. Coronary arteries were perfused with iodine- and gadolinium-based contrast agents. The DE K-edge subtractions were performed. Regions-of-interest were placed on histopathologically/radiographically-matched vascular lumen and wall, fibromuscular and calcified plaque, and fat tissues. Vascular/tissue contrast-to-noise ratios (CNR) were calculated, and their dependence on tissue type and contrast agent type was statistically evaluated. RESULTS: Tissue CNR analysis confirmed that all tissue types were successfully distinguished. Vascular wall and fibromuscular plaque achieved a significant increase in CNR ratios when DE techniques were used compared with 140 kV protocols. CONCLUSIONS: Spectral DE MDCT imaging of ex vivo atherosclerotic coronary arteries allows successful tissue characterization and enhances depiction of coronary lumen.

Angiography, Digital Subtraction↗