Moxifloxacin superior to vancomycin for treatment of bone infections--a study in rats.

BACKGROUND: Increasing resistance rates towards conventional antibiotics necessitate investigations of the efficacy of newly developed antibiotics. Thus, in a rat study, we compared the efficacy of moxifloxacin and vancomycin in the treatment of a local Staphylococcus aureus bone infection. METHOD: The femoral medullary cavities of 36 Wistar rats were contaminated with 100 muL of an oxacillin-sensitive Staphylococcus aureus strain (ATCC 29213) at 10(8) cfu/mL. On the seventh day, antibiotic treatment with moxifloxacin (10 mg/kg twice daily i.p.) or vancomycin (15 mg/kg twice daily i.p.) was commenced in 12 animals each. 12 control animals were left untreated. After 21 days, the infected femurs were explanted and the bacterial counts (cfu/g) were determined. RESULTS: In the control group, a median of 3.42 x 10(6) cfu/g (LQ/UQ 1.09 x 10(6)/ 1.55 x 10(7)) was cultured, with a median of 2.53 x 10(6) cfu/g (LQ/UQ 1.95 x 10(6)/ 4.25 x 10(6)) in the vancomycin group and a median of 2.49 x 10(5) cfu/g (LQ/UQ 2.84 x 10(4)/ 3.75 x 10(5)) in the moxifloxacin group. The bacterial count was reduced by treatment with moxifloxacin both in comparison with the control group (p < 0.001), and in comparison with treatment with vancomycin (p < 0.001). There was no statistically significant difference between the vancomycin group and the control group (p = 0.53). INTERPRETATION: In contrast to vancomycin, moxifloxacin proved to be an effective antibiotic for the treatment of bone infections due to Staphylococcus aureus in our animal model.

Animals↗

Position of the acetabular cup -- accuracy of radiographic calculation compared to CT-based measurement.

OBJECTIVE: A variety of mathematical and trigonometric methods has been described for determining the position of the acetabular cups from conventional radiographs. However, these formulae are subject to unduly large inaccuracies. The aim of the study was to compare the reliability and the accuracy of radiological and CT-based determination of acetabular cup position. MATERIALS AND METHODS: The positions of acetabular cups of 31 patients were calculated in conventional plain radiographs of the hip using the method described by Widmer. Further, in all patients computed tomograms of the pelvis were performed and the cup position was measured with the aid of a CT-based computer-assisted navigation software. As reference values inclination and anteversion of the cups were calculated in 3D reconstructions of the pelvis with the aid of an image processing software. RESULTS: The radiological measurement as well as the CT-based method showed good intra- and inter-observer reliability and no significant difference in the calculation of the inclination (p=0.409). However, CT-based determination of anteversion was significantly more exact than radiological measurement (p<0.001). The calculation of the cup anteversion from the X-rays showed serious deviations from the reference method and a substantial error range (X-ray: mean deviation +1.74 degrees, range -16.6 degrees to +29.8 degrees , S.D. +/-9.32 degrees; CT-based: mean deviation -0.74 degrees, range -6.6 degrees to +5.3 degrees, S.D. +/-2.87). CONCLUSION: For any clinical problem or for clinical studies in which acetabular positions of acetabular cups have to be exactly determined, CT-based measuring methods are obviously the method of choice. Evaluations based only on conventional plain X-rays and calculation of the acetabular cup position using the formula described by Widmer must be regarded as unreliable, particularly, because of problems in measuring the anteversion.

Acetabulum↗

Contaminant seeding in bone by different irrigation methods: an experimental study.

OBJECTIVE: This study was designed to investigate the effectiveness of using various devices and manual procedures for cleansing bacterially contaminated bone tissue and to assess the risk of iatrogenic bacterial seeding in deep bone layers. METHODS: In an in vitro model, human femoral heads were contaminated with Escherichia coli and then cleansed with pulsatile high-pressure lavage, pulsatile low-pressure lavage, manual rinsing with bulb syringe lavage, or manual rinsing with combined brush cleaning. The numbers of bacteria that remained or those that were introduced by the rinsing procedures were quantitatively determined at depths of 0 to 1 cm, 1 to 2 cm, and 2 to 3 cm. RESULTS: Both pulsatile high-pressure lavage and brush cleaning were more effective than pulsatile low-pressure lavage and bulb syringe lavage for the purpose of surface cleansing. The differences were highly significant (P < 0.001). There was no significant difference in the decontaminating effect between pulsatile high-pressure lavage and brush cleaning (P = 0.24). The bacterial contamination attributable to the cleansing procedure, as measured at tissue depths of 1 to 2 cm and 2 to 3 cm, was significantly higher after pulsatile high-pressure lavage and after pulsatile low-pressure lavage than it was after bulb syringe lavage or brush cleaning (P < 0.001). CONCLUSION: In this in vitro investigation of cancellous bone, the brush cleansing was just as effective for getting rid of bacterial contamination as pulsatile high-pressure lavage, and carries a significantly lesser risk of iatrogenic bacterial seeding into deeper tissue layers. In the light of these promising results obtained by the cleansing of cancellous bone contaminated with bacteria, it would be desirable to perform supplementary in vitro and in vivo investigations into brush cleansing.

Aged↗

Dose-dependent efficacy of diclofenac-cholestyramine on pain and periarticular ossifications after total hip arthroplasty: a double-blind, prospective, randomised trial.

INTRODUCTION: To investigate the efficacy of treatment with diclofenac-cholestyramine on postoperative pain and functional outcome after total hip arthroplasty, a randomised double-blind study was conducted. MATERIALS AND METHODS: A total of 245 patients received postoperative treatment with 75 mg or 150 mg diclofenac p.o. daily for 14 days. RESULTS: Patients who received 75 mg diclofenac per day needed paracetamol as an additional analgesic significantly more often (p=0.0162) than patients who were treated with 150 mg diclofenac daily (75 mg twice a day). The incidence of adverse gastrointestinal events was significantly lower in the group receiving 75 mg diclofenac daily than in the group receiving the higher dose (23.1% vs 37.1%; p=0.025). Six months after the operation, no differences were observed between the two groups with regard to pain or functionality measured in terms of overall mobility of the hip. No patient of either group developed clinically relevant heterotopic ossifications. CONCLUSION: Treatment with a dose of 75 mg diclofenac once daily-if necessary with the additional use of paracetamol-is a favourable option for the postoperative care of THA.

Acetaminophen↗

No difference between two doses of diclofenac in prophylaxis of heterotopic ossifications after total hip arthroplasty.

BACKGROUND: In a monocentric, randomized, placebo-controlled double-blind study, we investigated the efficacy of two doses of diclofenac-cholestyramine for the prevention of heterotopic ossification (HO). PATIENTS: The study comprised 245 patients undergoing total hip arthroplasty (THA). RESULTS: With 150 mg cholestyramine-bound diclofenac (2 x 1 capsule Voltaren resinate) daily during a postoperative period of 14 days, 19% of patients showed slight HO (Brooker grade 1), and no patient had more severe ossifications (grades 2-4). In the group receiving 75 mg daily (1 x 1 capsule), 17% of patients showed grade 1 HO and 4% grade 2 HO. No patient had grades 3-4 HO. No differences in clinical results were seen between the two groups 6 months after THA. INTERPRETATION: Since the rate of adverse gastrointestinal events was lower (23% versus 38%, p = 0.02) in the group receiving the lower dose, we recommend it.

Aged↗

Influence of acid-citrate-dextrose anticoagulant on blood quality in retransfusion systems after total knee arthroplasty.

The influence of acid-citrate-dextrose (ACD) anticoagulant on the blood quality was assessed in this prospective, randomized, controlled study. The clinical consequences with regard to retransfusion of drainage blood following total knee arthroplasty were evaluated. After total knee arthroplasty, retransfusion was performed utilizing a "SureTrans" retransfusion system in 81 patients. In 42 of them, blood was collected adding an ACD anticoagulant (group A), while in the remaining 39 patients blood was collected without any additives (group B). Blood losses were retransfused over a 6-h period after attaching the retransfusion system to the patient of either group. Blood samples of the 6-h blood collection were taken and analysed for several blood quality parameters. Significant differences were found in the platelet count (61,200+/-16,700 microl(-1) in group A versus 70,100+/-21,600 microl(-1) in group B, p=0.042), the lactate concentration (4.09+/-0.86 mmol/l vs 4.82+/-0.83 mmol/l, p<0.001), the pH (6.96+/-0.10 vs 7.18+/-0.06, p<0.001), as well as the protein content (5.44+/-0.57 g/dl vs 5.85+/-0.43 g/dl, p<0.001). These observed significant differences were, however, of no clinical relevance to the patients' treatment. Hemoglobin concentration, hematocrit, mean corpuscular volume (MCV), erythrocyte count, leukocyte count, concentration of free hemoglobin in the blood plasma (fHb), potassium concentration, lactate dehydrogenase (LDH), serotonin concentration, triglyceride concentration, free fatty acid concentration, and interleukin-6 concentration did not differ significantly. This study indicates that the blood quality in retransfusion systems is not substantially influenced by adding ACD anticoagulant.