PubMed Health⌕ Search

Biomedical subjects

Martin Hedström

Publications and source records attributed to Martin Hedström.

5 recordsLinked to original sources

Capture of bacterial endotoxins using a supermacroporous monolithic matrix with immobilized polyethyleneimine, lysozyme or polymyxin B.

Bacterial endotoxins (BEs) are integrated part of Escherichia coli, a microorganism widely used for the production of recombinant proteins. BEs should be eliminated in the course of down stream processing of target protein produced by these bacteria. Supermacroporous monolith (continuous bed) columns, so called cryogel columns, with immobilized polyethyleneimine (PEI), polymyxin B (PMB) and lysozyme were employed for BEs capture. Due to the large interconnected pores it was possible to use cryogel columns at flow rates as high as 10 ml/min. The columns packed with Sepharose CL-4B with immobilized PEI, PMB and lysozyme were impossible to use at these high flow rates due to the collapse of the bed. The dynamic capacities of the cryogel columns were nearly independent of the flow rate. In the presence of EDTA, BEs were quantitatively captured from mixtures with a model protein, bovine serum albumin (BSA) at pH 7.2 with practically no protein losses. At pH 3.6 BEs were captured directly from non-clarified E. coli cell lysate resulting in more than 10(4) times BEs clearance.

Chromatography, Affinity↗

Fast on-column protein digestion with subsequent peptide mapping using tandem mass spectrometry with information dependent acquisition.

A platform for rapid on-line protein digestion of protein mixtures for direct infusion to a mass spectrometer is presented. A mixture of protein A, staphylococcal enterotoxin B and cytochrome c was used as a model mixture injected on a gel filtration column and a trypsin reactor which were connected in series to a micro liquid chromatography (microLC) system. The peptides in the column eluate were analyzed with ESI tandem mass spectrometry, utilizing information dependent acquisition (IDA). In one step, the proteins in the mixture (microM concentrations) were concomitantly desalted, separated, digested and identified with an overall analysis time of less than 40 min. Protein sequence coverage of 78-95% for the involved substances was achieved.

Amino Acid Sequence↗

Purification and characterisation of acidocin D20079, a bacteriocin produced by Lactobacillus acidophilus DSM 20079.

Bacteriocins are natural antimicrobial agents produced by food fermentative bacteria. Lactobacillus acidophilus DSM 20079 produces a small bacteriocin, with a molecular mass of 6.6 kDa, designated acidocin D20079. This antimicrobial peptide was extremely heat-stable (30 min at 121 degrees C) and was active over a wide pH range. It was found to be sensitive to proteolytic enzymes (trypsin, ficin, pepsin, papain, and proteinase K). Acidocin D20079 has a narrow inhibitory spectrum restricted to the genus Lactobacillus which includes L. sakei NCDO 2714, an organism known to cause anaerobic spoilage of vacuum-packaged meat. Maximum production of acidocin D20079 in MRS broth was detected at pH 6.0, and the peptide was purified by ammonium sulphate precipitation followed by sequential cation exchange and hydrophobic interaction chromatography. Purified acidocin D20079 spontaneously formed spherulite crystals during dialysis. As the N-terminus was found to be blocked for sequencing, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry was used to determine a partial sequence, and the molecular mass of the bacteriocin in the formed crystals (6.6 kDa). Estimates of the molecular weight of the partially purified peptide, using tricine-SDS-PAGE, in which bacteriocin activity was confirmed by overlayer techniques were in accordance with this value.

Amino Acid Sequence↗

Continuous measurements of a binding reaction using a capacitive biosensor.

A capacitive biosensor with polyclonal antibodies raised against human serum albumin (HSA) immobilized on a gold transducer has been developed for continuous measurement of HSA in the muM-range. A mathematical model has been refined to describe integral HSA-binding curves assuming that (i) binding is essentially irreversible under the conditions used, (ii) the signal is scaled as the number of non-occupied binding sites and (iii) the rate of disappearance of available binding sites is scaled as the number of available binding sites and analyte concentration in solution. Deconvolution of the curves using the mathematical model indicates clearly that it is possible to retrieve concentration profiles (isocratic, linearly or exponentially increasing gradients) of the analyte in the continuous sample flow from the normalized integral binding (NIB) curves. The data presented constitutes the theoretical background and the first step towards the development of an analytical system allowing on-line detection of the concentration profile of the analyte from NIB-curves. Since the system can be used for extended time periods between regeneration steps, a low frequency of regeneration steps can be expected.

Antibodies↗

Improved methods for prepurification and detection of staphylococcal enterotoxin B from cell-free culture filtrate.

An improved ELISA method for the detection of Staphylococcal Enterotoxin B (SEB) in protein A preparations is presented. Fab fragments were obtained by digestion with papain of anti-SEB IgG bound to SEB immobilized on Sepharose 4B. Anti-SEB and peroxidase-labeled Fab fragments from secondary antibodies were successfully used in a modified ELISA of SEB in protein A preparations. SEB-Sepharose was used repeatedly for the production of anti-SEB Fab fragments by papain digestion without loss of affinity. In addition, for the purification of SEB from crude culture filtrates, an initial step utilizing a combined heat and pH treatment for the removal of significant amounts of contaminating proteins without losses of toxin activity is presented. This pretreatment step yielded positive effects in further downstream processing considering both shortened time and an increase in total recovery.

Calibration↗