PubMed Health⌕ Search

Biomedical subjects

Martin Heller

Publications and source records attributed to Martin Heller.

At least 19 recordsLinked to original sources

Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing.

To evaluate increased image latitude post-processing of digital projection radiograms for the detection of pulmonary nodules. 20 porcine lungs were inflated inside a chest phantom, prepared with 280 solid nodules of 4-8 mm in diameter and examined with direct radiography (3.0x2.5 k detector, 125 kVp, 4 mAs). Nodule position and size were documented by CT controls and dissection. Four intact lungs served as negative controls. Image post-processing included standard tone scales and increased latitude with detail contrast enhancement (log-factors 1.0, 1.5 and 2.0). 1280 sub-images (512x512 pixel) were centred on nodules or controls, behind the diaphragm and over free parenchyma, randomized and presented to six readers. Confidence in the decision was recorded with a scale of 0-100%. Sensitivity and specificity for nodules behind the diaphragm were 0.87/0.97 at standard tone scale and 0.92/0.92 with increased latitude (log factor 2.0). The fraction of "not diagnostic" readings was reduced (from 208/1920 to 52/1920). As an indicator of increased detection confidence, the median of the ratings behind the diaphragm approached 100 and 0, respectively, and the inter-quartile width decreased (controls: p<0.001, nodules: p=0.239) at higher image latitude. Above the diaphragm, accuracy and detection confidence remained unchanged. Here, the sensitivity for nodules was 0.94 with a specificity from 0.96 to 0.97 (all p>0.05). Increased latitude post-processing has minimal effects on the overall accuracy, but improves the detection confidence for sub-centimeter nodules in the posterior recesses of the lung.

Animals↗

Value of fat-suppressed PD-weighted TSE-sequences for detection of anterior and posterior cruciate ligament lesions--comparison to arthroscopy.

OBJECTIVE: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging for the detection of anterior and posterior cruciate ligament lesions in comparison to arthroscopy. MATERIALS AND METHODS: In a prospective study 31 knee joints were imaged on a 1.5T MR scanner (Vision, Siemens, Erlangen) prior to arthroscopy using following sequences: (a) sagittal FS-PDw/T2w TSE (TR/TE: 4009/15/105 ms); (b) sagittal PDw/T2w TSE (TR/TE:3800/15/105 ms). Further imaging parameters: slice thickness 3mm, FOV 160 mm, matrix 256 x 256. A total of 62 anterior and posterior cruciate ligaments (ACL/PCL) were evaluated, standard of reference was arthroscopy. Sensitivity, specificity, positive (ppv) and negative predictive value (npv) and accuracy were calculated. RESULTS: Twenty-one cruciate ligament ruptures were detected in arthroscopy, 19 ACL- and 2 PCL-ruptures (on MRI 34/124, 25/62 ACL, 9/62 PCL lesions). For all four sequences in the 31 patients with arthroscopic correlation sensitivity, specificity, ppv, npv and accuracy were 86%, 98%, 95%, 93% and 94% for detection of tears, and 84%, 100%, 100%, 80% and 90% for ACL-ruptures respectively. The two PCL-ruptures were true positive in all sequences, one intact PCL was diagnosed as torn (false positive). CONCLUSIONS: Fat-suppressed PDw/T2w TSE-MR sequences are comparable to PDw TSE sequences for the detection of ACL/PCL-lesions.

Adolescent↗

Experimental and clinical evaluation of acromioclavicular joint structures with new scan orientations in MRI.

The objective of the study was to evaluate MRI for visualization of acromioclavicular (ac) joint structures in cadaveric shoulders, asymptomatic volunteers and symptomatic patients with trauma of the ac-joint. Three cadaveric shoulders were examined to find adequate planes and sequences for MRI. Afterwards, MR images were correlated to corresponding anatomical sections. Six asymptomatic volunteers and 13 patients were scanned in a 1.5 T Magnetom Vision with three sequences in the following planes: (1) parallel to the clavicle; (2) orthogonal to the ac joint, each time a fat-suppressed proton density-weighted + T2-sequence (TR/TE 4,000/15 ms) was performed; (3) parallel to the clavicle, T1-SE (TR/TE 817/20 ms). The parameters were: slice thickness 3 mm, field-of-view 180 mm, matrix 210x256 pixels. Standard of reference in the patients was clinical examination and conventional X-rays. Classification was by Rockwood grades I-VI. MRI allowed excellent visualization and diagnoses of ac-joint structures in volunteers and patients (n=6 normal, n=1 Rockwood I, n=5 Rockwood II, n=3 Rockwood III, n=4 Rockwood V). On MRI, in one lesion type II and III each, a lower lesion type was suspected clinically and by X-ray. In one patient additional information by MRI led to surgery. MRI allows excellent anatomical display of ac-joint structures and can give clinically relevant information on type and extension of ac-joint trauma, which may influence therapy.

Acromioclavicular Joint↗

Influence of various cell-detachment solutions on endothelial cells after catheter abrasion for prosthesis colonization prior to implantation.

We (1) evaluated the effectiveness of different media on the detachment of endothelial cells (ECs) from a catheter brush (Cragg thrombolytic catheter system) that was previously used for endothelial cell abrasion in 10 cm human umbilical vein (HUV) segments; (2) tested the practicability of endovascular catheter brush abrasion followed by EC detachment from the catheter brush, in vitro culture of harvested ECs, and finally endothelialization of a prosthesis; and (3) analyzed the defect created by the catheter brush in HUV segments after endovascular catheter abrasion. Best results in detachment of ECs from the catheter brush were obtained with a mixture of phosphate-buffered saline + 1% human albumin. EC vitality was time-dependent in the collected HUV segments postdelivery. Harvested EC viability decreased from (26.28 +/- 5.76)% (0-3 h postdelivery) to (17.29 +/- 4.56)% (after 4-8 h). ECs were easily cultured ex vivo within 2-3 weeks; seeded on nitinol stents, they grew to confluency and formed a monolayer on the stent surface (determined by scanning electron microscopy - SEM). Histological and SEM analysis of HUV segments that had undergone previous catheter brush abrasion revealed slight disruption of the intima but intact subintimal layers. Our findings indicate an advantageous method of capturing and culturing primary ECs for gene therapy or for the analysis and diagnosis of certain blood vessel diseases, especially in cases in which endovascular intervention is performed anyway. Moreover, and of high relevance to the biomaterial field, theoretically the procedure could be used to endothelialze a prosthesis ex vivo for implantation into the patient from whom the ECs were harvested, to reduce the inherent thrombogenicity of the prosthesis.

Catheter Ablation↗

MR-guided breast biopsy using an active marker: a phantom study.

PURPOSE: To evaluate the advantages of using an active marker (active micro coil) for MR-guided breast biopsy procedures. MATERIALS AND METHODS: An add-on breast biopsy guidance device used with a standard breast coil was equipped with an active marker. The marker's position was determined with a dedicated MRI sequence. In combination with custom software, the biopsy planning process was reduced basically to defining the target in the diagnostic MR images. Automatic control scans verified the settings of the biopsy guidance device. To measure the targeting accuracy, x-ray control of the needle placement was performed in phantoms containing 36 small titanium cylinders. The reliability of the procedure was evaluated in 24 core needle biopsies on phantoms. Workflow enhancements were analyzed. RESULTS: The root mean square deviation of the needle position from the target perpendicular to the needle axis was 1.25 mm, in three-dimensions it was 1.35 mm. All targets were sampled successfully. The duration of a phantom biopsy was nine minutes. CONCLUSION: The use of an active marker can offer advantages for MR-guided breast biopsies in terms of handling and procedure time as well as accuracy.

Biomarkers↗

Reproducibility of computer-aided volumetry of artificial small pulmonary nodules in ex vivo porcine lungs.

OBJECTIVE: The main purpose of this study was to investigate the reproducibility of computed tomography (CT)-based volumetric measurements of small pulmonary nodules. METHODS: We implanted 70 artificial pulmonary nodules in 5 ex vivo porcine lungs in a dedicated chest phantom. The lungs were scanned 5 times consecutively with multislice-CT (collimation 16 x 0.75 mm, slice thickness 1 mm, reconstruction increment 0.7 mm). A commercial software package was used for lesion volumetry. The authors differentiated between intrascan reproducibility, interscan reproducibility, and results from semiautomatic and postprocessed volumetry. RESULTS: Analysis of intrascan reproducibility revealed a mean variation coefficient of 6.2% for semiautomatic volumetry and of 0.7% for human adapted volumetry. For interscan reproducibility a mean variation coefficient of 9.2% and for human adapted volumetry a mean of 3.7% was detected. CONCLUSION: The presented volumetry software showed a high reproducibility that can be expected to detect nodule growth with a high degree of certainty.

Analysis of Variance↗

Stent placement with the monorail technique for treatment of mesenteric artery stenosis.

PURPOSE: To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. MATERIALS AND METHODS: In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. RESULTS: Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. CONCLUSIONS: Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.

Adult↗

Treatment of acute pulmonary embolism: local effects of three hydrodynamic thrombectomy devices in an ex vivo porcine model.

PURPOSE: To report an ex vivo study on the local effects of hydrodynamic thrombectomy for the treatment of acute pulmonary embolism (off-label use). METHODS: Three devices (6-F AngioJet Xpeedior and 6-F and 8-F Oasis) were used for hydrodynamic thrombectomy inside the arteries of 24 inflated and perfused porcine lung explants. Each system was used at multiple positions inside 4 intact and 4 embolized lungs in vessels measuring 2 to 4 mm, 4 to 6 mm, 6 to 8 mm, and 8 to 10 mm. Angiograms prior to, during, and after catheter positioning and system operation were used to detect arterial wall trauma and to measure local clot removal per 30-second cycle. A total of 21 vessel wall samples were subjected to scanning electron microscopy (SEM) to evaluate non-perforating lesions. RESULTS: All systems were able to remove clot material. The average recanalized vessel length normalized to 30 seconds for vessel diameters of 2 to 4 and 8 to 10 mm, respectively, was 1.17 and 1.75 cm (AngioJet), 0.97 and 0.25 cm (6-F Oasis), and 2.2 and 1.05 cm (8-F Oasis). Perforations occurred during positioning of the 6-F Oasis (4/78 maneuvers) and 8-F Oasis (13/60), but not the AngioJet (0/89); perforations were also seen during system operation (AngioJet: 21/89 activations, 6-F Oasis: 4/78, and 8-F Oasis: 9/60; all lesions inside vessels <6 mm in diameter). SEM showed 35 lesions, 14 with perforation (contrast extravasation) and 21 without perforation (induced by the tip of the guidewire). CONCLUSION: The AngioJet was most efficient in clot removal, followed by the 8-F Oasis. The 6-F Oasis was least efficient, but had fewest complications. According to these experiments, the tested hydrodynamic thrombectomy devices may cause perforations in vessels <6 mm in diameter. Changes in catheter design to reduce system-specific complication rates or to improve the efficacy of clot removal are warranted.

Acute Disease↗

Low-profile stent placement with the monorail technique for treatment of renal artery stenosis: midterm results of a prospective trial.

PURPOSE: To determine feasibility, safety, and midterm patency of a monorail balloon stent device for the treatment of renal artery stenosis (RAS). MATERIALS AND METHODS: During a period of 30 months, 47 patients (with severe hypertension, n=45; renal insufficiency, n=20) with 50 cases of RAS and indications for stent implantation (calcified ostial lesion, n=41; insufficient percutaneous transluminal angioplasty, n=6; dissection, n=3) were enrolled into the prospective evaluation. After predilation, 59 stents (Rx-Herculink 4 mm, n=2; 5 mm, n=19; 6 mm, n=35; 7 mm, n=3) were implanted under manometer control with use of the long-sheath technique (5 F; 6 F for 7-mm stents) via a femoral (n=44) or transbrachial approach (n=6). Parameters of hypertension and renal insufficiency were determined before and after the procedure and for a maximum of 18 months. Restenosis rate was determined with color duplex ultrasonography. RESULTS: Renal artery stent placement (mean diameter, 5.7 mm; mean length, 16 mm) was technically successful in all cases (100%). Mean blood pressure and serum creatinine level decreased from 177/93 mm Hg to 145/78 mm Hg and from 1.8 mg/dL to 1.5 mg/dL, respectively. Within 48 hours after the implantation, acute occlusions occurred in two patients, supposedly triggered by cholesterol embolization. Primary and primary assisted patency rates were 87% and 92% at 6 months and 75% and 84% at 18 months. CONCLUSIONS: Renal artery stent placement with the rapid-exchange monorail system is a safe procedure with promising patency rates. In combination with the long-sheath technique, adequate control of stent deployment is guaranteed during the entire intervention. The low profile of the device facilitates the use of small sheaths (5 F) to minimize access-site complications.

Aged↗

2005 Dr. Gary J. Becker Young Investigator Award: periprocedural oral administration of the leflunomide analogue FK778 inhibits neointima formation in a double-injury rat model of restenosis.

PURPOSE: To test the efficacy of limited oral administration of the new leflunomide analogue FK778 for suppression of neointima proliferation in a double-injury restenosis model in the rat. MATERIALS AND METHODS: For induction of aortic lesions, silicon cuffs were placed operatively around the infrarenal aortas of Lewis rats. After 21 days, the aortic cuffs were removed and the lesions were dilated with 2-F Fogarty catheters inserted via the left common carotid artery. The novel immunosuppressant FK778 was administered at a dose of 5 mg/kg body weight (group 1) or 15 mg/kg body weight (group 2) in a total of 38 animals. For both doses, three different periinterventional time periods, each with a 5-day course of oral FK778, were defined as follows: (i) days -2 to 2, (ii) days 1-5, and (iii) days 7-11, with six or seven rats in each group. After 3 weeks, intima/media ratios were assessed morphometrically and immunohistochemistry for quantification of intimal alpha-actin expression was performed. RESULTS: In both dose groups, there was a trend toward inhibition of neointima formation when the 5-day course of FK778 was started before or 1 day after the intervention. However, in the lower-dose group, inhibition of neointima was not statistically significant regardless of the time frame of treatment (groups 1a-c). With the higher dose, suppression of intimal hyperplasia was significant when FK778 was administered between days 1 and 5 after angioplasty (group 2b; P<.01). Expression of alpha-actin in the intima of FK778-treated rats was significantly reduced when the drug was started 2 days before angioplasty in group 1a (P<.05) or 1 day after angioplasty in both dosage groups (group 1b, P<.01; group 2b, P<.05). CONCLUSION: In the double-injury rat model presented, balloon-mediated proliferation of smooth muscle cells in the intima with consecutive intimal thickening was influenced by FK778 in a dose-dependent manner. However, long-term studies are needed to exclude a delay of vascular healing in this particular model.

Actins↗

Vessel wall damage caused by cerebral protection devices: ex vivo evaluation in porcine carotid arteries.

PURPOSE: To determine the extent of vessel wall damage caused by cerebral protection devices designed for carotid angioplasty by using ex vivo porcine carotid arteries. MATERIALS AND METHODS: The local animal experimentation committee did not require its approval for this study. With a benchtop vascular model (flow rate, 470 mL/min; dicrotic pulsatile flow, 76 pulses per minute; pressure, 115/67 mm Hg [mean pressure, 91 mm Hg]) into which 85 porcine internal carotid arteries (ICAs) were inserted, five different protection devices (Angioguard [Cordis/Johnson & Johnson, Miami, Fla], Filterwire EX [Boston Scientific, Natick, Mass], Trap [Microvena, White Bear Lake, Minn], Neuroshield [Abbott Laboratories, Redwood City, Calif], and Percusurge [Abbott Laboratories]) were evaluated. Adverse movement (1 cm up, 2 cm down, and 1 cm up again) of the activated devices (deployed filters or inflated balloons [Percusurge only]) was simulated, and the device was retrieved. For each of these steps (deployment, movement, retrieval) the amount of debris from the vessel wall in the effluent of the ICA was determined by using a 100-microm filter. The Mann-Whitney test was used to test for differences, and a correction for multiple comparisons was made. P < .05 was considered to indicate a significant difference. The authors attempted to determine whether there was a notable association between the total amount of debris captured and the classification of damage at microscopy. Carotid arteries were analyzed histologically with light and scanning electron microscopy. RESULTS: All examined protection devices caused dislodged debris, which was captured in the effluent filter. There were significant differences among the devices in terms of the total amount of debris captured in the filters (lowest amounts of debris, 4.75 mg [Angioguard] and 5.02 mg [Filterwire EX]; highest amount, 7.51 mg [Trap]; P < or = .001 for all). All devices caused histologically visible wall damage, with the degree of intimal denudation correlating with the mass of the debris. The Trap device caused the most severe intimal and subintimal wall damage. Adverse movement resulted in no increased debris dislodgment as compared with the debris dislodged during deployment and retrieval of the devices. CONCLUSION: On the basis of the data obtained, cerebral protection devices themselves have a potential influence on embolization rates by causing debris to be dislodged during carotid stent placement.

Angioplasty, Balloon↗

Characterization of a new double-injury restenosis model in the rat aorta.

PURPOSE: To characterize a new rat model of restenosis for evaluation of local or systemic drug strategies. METHODS: Arterial lesions were induced by placement of silicone cuffs around the aorta of Lewis rats. After 21 days, the cuffs were removed, and a subgroup of rat aortas was subjected to secondary balloon injury. Remodeling of wall compartments and cell kinetics were assessed morphometrically at 3, 7, 14, 21, and 28 days after the single and double-injury approaches. Immunohistochemistry was used to assess the distribution of macrophages, smooth muscle cells, and proliferating cells within the layers of the arterial wall in the experimental groups versus sham-operated and untreated controls. RESULTS: After cuff placement, the adventitia initially undergoes significant enlargement, while the media shows a reduction in relative thickness. Accumulation of cells within the adventitia at 3 and 7 days is followed by a marked decline in cell density at 14 days, with simultaneously increasing cell numbers in the intima. At this time, activated macrophages are detected in the adventitia, indicating chronic inflammation. Following cuff placement, mild intimal hyperplasia develops. In the double-injury model, extensive neointimal hyperplasia forms rapidly, with a peak at 14 days. CONCLUSIONS: This new double-injury model is technically easy, and multiple experiments can be accrued in short periods of time. It provides an additional platform to identify new targets and strategies for the prophylaxis of postangioplasty restenosis.

Actins↗

Short-term rapamycin for inhibition of neointima formation after balloon-mediated aortic injury in rats: is there a window of opportunity for systemic prophylaxis of restenosis?

PURPOSE: To evaluate the efficacy of limited short-term systemic administration of rapamycin to prevent neointimal intimal hyperplasia (NIH) in a double-injury rat model of restenosis. METHODS: Aortic lesions were induced by perivascular placement of silicone cuffs around the aorta of 36 Lewis rats. After 3 weeks, the cuffs were removed, and the vessels were subjected to secondary balloon injury. Rapamycin (sirolimus) was intravenously administered for 5 days in dosages of 0.5 or 2 mg/kg/d beginning at various time points relative to the balloon injury: (1) days -2 to +2, (2) days 1 to 5, or (3) days 7 to 11. For each treatment period, 6 rats received the 5-day course of the lower or higher dose of rapamycin. Eight rats served as controls undergoing 2-stage injury without rapamycin treatment. Morphometry and immunohistochemistry were performed at 21 days after angioplasty. RESULTS: NIH and intimal alpha-actin expression were inhibited by both dosages when treatment started 2 days before or 1 day after angioplasty. Results were statistically significant for the lower dose when started 1 day after angioplasty (p < 0.01) and for the higher dose when initiated 2 days before the intervention (p < 0.05). Treatment commencing at 7 days did not reduce NIH in either dosage group. CONCLUSIONS: In a double-injury rat model, NIH can be inhibited by short-term systemic rapamycin, but suppression of early cell migration and proliferation is pivotal. A limited peri-interventional antiproliferative therapy may be of value as an adjunct to control restenosis after balloon angioplasty and/or stenting.

Actins↗

Assessing bone status beyond BMD: evaluation of bone geometry and porosity by quantitative ultrasound of human finger phalanges.

UNLABELLED: In an in vitro study, we found significant associations between QUS variables and properties and geometrical parameters of the compact bone of human finger phalanges. QUS variables were not only related to BMD but also to other skeletal properties, which explained 70% of the variability of speed of sound. INTRODUCTION: Transverse transmission quantitative ultrasound (QUS) measurements at the finger phalanges are known to be correlated with BMD and to predict osteoporotic fractures. To determine which other skeletal properties are affected by ultrasound, we investigated the impact of density, geometry, and porosity on QUS variables in vitro. MATERIALS AND METHODS: Ultrasound variables were correlated with density, porosity, and geometrical characteristics of cortical bone. Additionally, we tested which combinations of geometry and bone properties best predicted the ultrasound results observed. Forty-four proximal phalanges from the middle finger were investigated at their distal metaphysis, similar to the typical clinical measurement procedure. Donor age ranged from 52 to 98 years (15 males and 29 females; mean age, 80.9 +/- 9.4 years). QUS variables were measured on the metaphysis of the phalanges using the DBMSonic 1200. Quantitative CT was used for the measurement of BMD, and high-resolution MRI was used for the measurement of porosity and geometrical variables. RESULTS: Speed of sound (SOS) and the clinically used variable AD-SOS correlated significantly with area, relative area, density, and porosity of the compact bone (R2 = 0.28-0.58, p < 0.0001). Signal amplitude correlated significantly only with relative area of the compact bone and area of the medullary canal (R2 = 0.18-0.20, p < 0.01). The combination of cortical area, density, and porosity improved the determination of SOS to R2 = 0.70, with a residual unexplained variability of 54 m/s (3.2%). CONCLUSIONS: These results clarify the impact of skeletal properties on QUS variables. SOS is affected by cortical area, cortical bone density, and cortical porosity, whereas attenuation only depends on geometry of the medulla. AD-SOS, the variable routinely measured in clinical practice, is primarily affected by cortical area. QUS of the finger phalanges is not only related to BMD but also to other skeletal properties.

Absorptiometry, Photon↗

Volumetric interpolated contrast-enhanced MRA for the diagnosis of pulmonary embolism in an ex vivo system.

PURPOSE: To implement a three-dimensional gradient-recalled echo (GRE) volumetric interpolated breath-hold examination (VIBE) sequence for pulmonary contrast-enhanced MRA (CE-MRA) in an experimental setup. MATERIALS AND METHODS: Eight porcine lungs were intubated, inflated inside a chest phantom, and examined at 1.5 T during slow perfusion (2-300 mL/minute). Three-dimensional-MRA was performed with and without contrast agent using three-dimensional-GRE (VIBE) with TR/TE = 4.5/1.9 msec, TA = 23 seconds, FOV = 390 mm, FA = 12 degrees /30 degrees, as well as a standard three-dimensional-GRE sequence and T2 fast spin-echo (FSE) sequences. Four of the eight lungs were embolized with autologous blood clots. By consensus readings, two observers evaluated the detectability of peripheral vessels, signal intensity over vessels and lung, and visualization of emboli. Digital subtraction angiograms served as a control to document vessel patency. RESULTS: Prior to contrast administration, three-dimensional-VIBE/12 degrees yielded the best results for lung parenchyma signal and visualization of small vessels (third-order, P < 0.01); however, no emboli were detected (due to lack of contrast). After administration of contrast agent, three-dimensional-GRE (VIBE) at FA = 30 degrees provided significantly better results (fifth-order branches, documentation of subsegmental occlusions [fourth order], P < 0.01). T2-FSE images documented water uptake into the lungs. Digitally subtracted angiography (DSA) confirmed the patency of seventh-order branches. CONCLUSION: This ex vivo study confirms the potential advantages of using a dual MR investigation for pulmonary embolism, combining three-dimensional-GRE (VIBE) at FA = 12 degrees to image lung parenchyma and at FA = 30 degrees for CE-MRA..

Angiography, Digital Subtraction↗

An in vitro analysis of a carotid artery stent with a protective porous membrane.

PURPOSE: To prove the effectiveness of a new stent concept with integrated protection (MembraX [MX]) by comparing it with five cerebral protection devices designed for carotid angioplasty in an in vitro model. MATERIALS AND METHODS: Two simulation series of embolization from carotid angioplasty have been performed. In the first series, polyvinyl-alcohol particles (150-250 microm [small], 355-500 microm [medium], 710-1000 microm [large]; 5 mg each) were injected into a silicone flow model simulating the aortic arch with a carotid bifurcation. The particles were injected proximally to the partially deployed MX stent or one of the following protection devices: Angioguard (AG), FilterWire EX (EX), Trap, Neuroshield (NS), or GuardWire Plus (GW). Particles evading the protection device were caught in a filter at the end of the flow model and weighed. In the second series, human plaque material (8-12 particles; total weight 6.09 +/- 0.01 mg; 500-1500 microm) was injected into the model with the respective devices. MX was compared with the AG, EX, Trap, and NS devices. RESULTS: MX had the most effective overall filtration performance for polyvinyl alcohol particles in the effluent of the internal carotid artery (ICA; 0.43 mg, 2.9%), compared with NS (0.53 mg, 3.5%), GW (1.10 mg, 7.0%), EX and AG (1.18 and 1.21 mg, respectively; 7.8% and 8.0%), and Trap (1.24 mg, 8.2%). MX performed best for the small particles (2.0% passed particles into ICA; P < .05 compared with all). Human plaque material was retained best in the in vitro model by MX (0.0%), followed by NS (0.8%), EX (1.3%), Trap (2.6%), and AG (4.4%). CONCLUSIONS: In vitro, none of the tested devices had the ability to prevent embolization completely. Comparing current designs, the MX device captured the highest percentage of the three different particle groups. Tested with human plaque emboli, MX performed effectively in filtering the particles in the ICA.

Analysis of Variance↗

Comparison of 4 cerebral protection filters for carotid angioplasty: an in vitro experiment focusing on carotid anatomy.

PURPOSE: To assess the influence of internal carotid artery (ICA) tortuosity on the effectiveness of 4 cerebral protection filters in an in vitro bench-top model. METHODS: To simulate the anatomical arterial variants, 3 open flow models were constructed: one with normal carotid anatomy, 1 representing a mildly tortuous ICA, and a third imitating a severely tortuous ICA. Polyvinyl alcohol particles (150-1000 microm) served as the embolic material; the emboli were divided into 3 groups according to size: small (150-250 microm), medium (355-500 microm), and large (710-1000 microm). Five milligrams of each size group were injected separately into the ICA proximal to each of 4 protection filters: AngioGuard, FilterWire EX, TRAP, and NeuroShield. Emboli that were not caught by the protection system or were washed into the external carotid artery (ECA) ran into an effluent filter and were weighed and classified according to size. RESULTS: In 240 test runs, the FilterWire EX presented the lowest weight of emboli in the ICA effluent under all anatomical conditions: normal anatomy 0.39 mg (2.58%), mild tortuosity 0.45 mg (2.99%), and severe tortuosity 0.50 mg (3.33%) (p>0.05). The Angioguard system showed the worst results: normal 1.21 mg (98.03%), mild tortuosity 2.54 mg (16.84%), and severe tortuosity 3.14 mg (20.91%) (p<0.001) compared to the FilterWire EX and the NeuroShield systems. The only protection device displaying no significant differences in all of the 3 emboli sizes was the FilterWire EX (p>0.05). Relevant differences in effectiveness in mildly and severely tortuous ICAs were apparent among the other devices. For all emboli sizes, the differences of the AngioGuard and TRAP systems were highly significant (p<0.001). There was no significant difference between the FilterWire EX and the NeuroShield. CONCLUSIONS: The only protection device showing no significant decrease in efficacy in the tortuous ICA models was the FilterWire EX. In both tested anatomical variants, the protection systems ranked in the same order of effectiveness. None of the tested devices prevented embolization completely.

Balloon Occlusion↗