PubMed Health⌕ Search

Biomedical subjects

Martin Köcher

Publications and source records attributed to Martin Köcher.

10 recordsLinked to original sources

Impact of diffusion-weighted MRI-measured initial cerebral infarction volume on clinical outcome in acute stroke patients with middle cerebral artery occlusion treated by thrombolysis.

INTRODUCTION: Magnetic resonance imaging (MRI) may help identify acute stroke patients with a higher potential benefit from thrombolytic therapy. The aim of our study was to assess the correlation between initial cerebral infarct (CI) volume (quantified on diffusion-weighted MRI) and the resulting clinical outcome in acute stroke patients with middle cerebral artery (MCA) (M(1-2) segment) occlusion detected on MRI angiography treated by intravenous/intraarterial thrombolysis. METHODS: Initial infarct volume (V(DWI-I) ) was retrospectively compared with neurological deficit evaluated using the NIH stroke scale on admission and 24 h later, and with the 90-day clinical outcome assessed using the modified Rankin scale in a series of 25 consecutive CI patients. The relationship between infarct volume and neurological deficit severity was assessed and, following the establishment of the maximum V(DWI-I) still associated with a good clinical outcome, the patients were divided into two groups (V(DWI-I) < or =70 ml and >70 ml). RESULTS: V(DWI-I) ranged from 0.7 to 321 ml. The 24-h clinical outcome improved significantly (P=0.0001) in 87% of patients with a V(DWI-I) < or =70 ml (group 1) and deteriorated significantly (P=0.0018) in all patients with a V(DWI-I) >70 ml (group 2). The 90-day mortality was 0% in group 1 and 71.5% in group 2. The 90-day clinical outcome was significantly better in group 1 than in group 2 (P=0.026). CONCLUSION: Clinical outcome could be predicted from initial infarct volume quantified by MRI-DWI in acute CI patients with MCA occlusion treated by intravenous/intraarterial thrombolysis. Patients with a V(DWI-I) < or =70 ml had a significantly better outcome.

Diffusion Magnetic Resonance Imaging↗

Combined strategy in AAA elective treatment.

The authors describe surgical treatment for high risk patients with abdominal aortic aneurysms of complicated morphology for standard endovascular repair. This was achieved by combining endovascular stent-grafting for aneurysmal sac exclusion with conventional vascular surgical procedures.

Aortic Aneurysm, Abdominal↗

Endovascular treatment of abdominal aortic aneurysms--6 years of experience with Ella stent-graft system.

PURPOSE: Evaluation of 6-year results of abdominal aortic aneurysm (AAA) treatment by Ella stent-grafts with regard to safety and effectivity in relation to morphology of the aneurysm. METHODS: From a group of 172 patients with AAA, in whom elective endovascular treatment was considered, 120 of them (69.8%) were found to be suitable for this type of therapy. The bifurcated type of stent-graft was implanted in 97 patients, uniiliacal type in 19 patients and only four patients were found to be suitable for tubular type of stent-graft. Additional necessary procedures (internal iliac artery occlusion or contralateral common iliac artery occlusion in a group of patients with uniiliacal type of stent-graft) were performed surgically during the stent-graft implantation. CT and US controls were performed at 3, 6 and 12 months after implantation, later every 12 months. RESULTS: Primary technical success was achieved in 109 of the 120 patients (91%). Primary endoleak was recorded in 11 patients (primary endoleak type Ia in seven patients, type Ib in three patients and type IIIa in one patient). Assisted technical success after reintervention or spontaneous seal was 98.3%. Surgical conversion was indicated in two patients (1.7%). Perioperative mortality rate was 3.3%. Total average follow-up period was 20.7 months (range from 2 to 60 months). In nine patients (7.5%) secondary endoleak type II was found at control CT or US, in three patients partial thrombosis of the stent-graft was found. There was no aneurysm rupture during follow-up. CONCLUSION: Treatment of AAA with Ella stent-graft system is effective and safe. Bifurcated stent-graft is the most frequently used type. Uniiliacal type of stent-graft is used by us only in cases of complicated morphology.

Aged↗

Femoral - internal iliac bypass in aortoiliac aneurysms endovascular repair.

The authors describe femoral - internal iliac bypass creation to remove ischemic complications in aortoiliac aneurysm endovascular repair. Based on a good experience with bypass in 6 patients they recommend its preventive indication when both internal iliac arteries are overstented.

Aortic Aneurysm, Abdominal↗

AAA elective treatment indication tactics in EVAR era.

The authors describe their indication tactics for AAA elective treatment. Based on one-month morbidity and mortality they evaluate the results obtained in the past six years and compare the methods of open surgery, endovascular repair and combined strategy in AAAs elective repair.

Aortic Aneurysm, Abdominal↗

Endovascular treatment of central venous stenoses in patients with dialysis shunts.

OBJECTIVE: Evaluation of long-term results of percutaneous treatment of central vein stenoses or occlusions in patients with haemodialysis shunt. MATERIALS AND METHODS: In 26 patients with haemodialysis shunts and confirmed central vein stenosis or occlusion, 28 primary percutaneous transluminal angioplasties (PTA) and 5 repeated PTAs (re-PTA) were performed; in three patients a stent was implanted - primary in one patient and due to early restenosis after PTA in two patients. To maintain stent patency, 10 re-PTA were performed. RESULTS: The technical success rate of primary interventions was 96 % (100 % in stenoses and 50 % in occlusions). Primary post-PTA patency rate was 70 % at 3 months, 60 % at 6 months and 30 % at 12 months. CONCLUSION: PTA with possible stent implantation is a first-choice method in the treatment of stenoses and occlusions of the central venous system. Despite the relatively frequent re-interventions, endovascular treatment is capable to preserve long-term function of the dialysis shunt.

Adult↗

Venous hypertension following average arterious-venous fistula for haemodialysis.

The authors emphasize the need for the investigation of the central venous system prior to the insertion of an avfistula, this they consider to be of utmost importance in patients with anamnesis of central vessel access. After the av-fistula is inserted, an unrecognized obstacle (stenosis or thrombosis) may result in the occurrence of venous hypertension and hypofunction, this may lead to av-fistula malfunction.

Arteriovenous Shunt, Surgical↗