PubMed Health⌕ Search

Biomedical subjects

Martin M F Choi

Publications and source records attributed to Martin M F Choi.

12 recordsLinked to original sources

Development and analytical application of an uric acid biosensor using an uricase-immobilized eggshell membrane.

An uric acid biosensor fabricated from a uricase-immobilized eggshell membrane and an oxygen electrode was presented. The detection schemes involve the enzymatic reactions of the uricase leading to the depletion of dissolved oxygen level upon exposure to uric acid solution. The decrease in oxygen level was monitored and related to the uric acid concentration. The scanning electron micrographs show the microstructure of the eggshell membrane within which the uricase is successfully immobilized. The effects of enzyme loading, pH, temperature, and phosphate buffer concentration on the response of the biosensor were investigated in detail. The uric acid biosensor has a linear response range of 4.0-640 microM with a detection limit of 2.0 microM (S/N=3). The response time was less than 100 s. The biosensor exhibited good repeatable response to a 0.10mM uric acid solution with a relative standard deviation of 3.1% (n=7). The reproducibility of fabrication of the biosensors using four different membranes was good with a R.S.D. of 3.2%. The biosensor showed extremely good stability with a shelf-life of at least 3 months. Some common potential interferents in samples such as glucose, urea, ascorbic acid, lactic acid, glycine, DL-alpha-alanine, DL-cysteine, KCl, NaCl, CaCl2, MgSO4, and NH4Cl showed no interferences on the response of the uric acid biosensor. The biosensor was successfully applied to determine the uric acid level in some human serum and urine samples, and the results agreed well with those obtained by a commercial colorimetric assay kit.

Animals↗

On-line monitoring of methanol in n-hexane by an organic-phase alcohol biosensor.

An organic-phase alcohol biosensor has been developed by co-entrapping alcohol oxidase and horseradish peroxidase within an ionotropy polymer hydrogel matrix fabricated from silica gel particles, hydroxyethyl carboxymethylcellulose, an adduct of 3-methoxy-4-ethoxybenzaldehyde and 4-tert-butylpyridinium acetohydrazone, and octadecylsilica particles. The viability of the immobilised enzymes for the biocatalytic reaction of methanol in n-hexane was comparatively studied by using a bulk cell or a volume-changeable flow-through cell coupled with an oxygen optical transducer. It was found that the microenvironment around the enzyme, the deterioration property of the enzyme, the substrate throughput and the mass transfer process of the reactant in the bioreactor were the crucial parameters affecting the performance of the alcohol organic-phase biosensor. Our optimal biosensor was constructed from a flow-through cell packed with small particles of immobilised enzymes and it could maintain the biocatalytic reaction at high and stable rate for on-line detection of methanol in n-hexane under flow operation mode. The biosensor had an analytical working range of 2.3-90 mM methanol in n-hexane. The response times (t95) were 4.5 and 7.5 min for 60 and 10 mM methanol, respectively. The operational lifetime of the biosensor was more than 45 assays and the shelf lifetime was longer than 2 weeks. The biosensor has been successfully applied to determine the methanol content in a commercial gasoline-methanol blend sample with good recovery.

Alcohol Oxidoreductases↗

Ion-pair chromatographic separation of water-soluble gold monolayer-protected clusters.

We demonstrate the efficacy of ion-pair chromatography for separations of samples of charged, polydisperse, water-soluble gold nanoparticles protected by monolayers of N-acetyl-l-cysteine and of tiopronin ligands. These nanoparticle mixtures have 1-2-nm-diameter Au core sizes as estimated from UV-visible spectra of the separated components. This size range encompasses the transition from bulk metal to molecular properties. The nanoparticle mixtures were resolved, the smallest nanoparticles eluting first, on an octadecylsilyl (C18) column using isocratic elution with a methanol/water mobile phase containing tetrabutylammonium fluoride (Bu4N+F-) and phosphate buffer. The column retention increases with Bu4N+F- concentration, lowered pH, and decreasing methanol volume fraction. The retention mechanism is dominated by ion-pairing in either the mobile phase or at the stationary/mobile-phase interface. Size exclusion effects, used in many previous nanoparticle separations, are insignificant.

Journal Article↗

An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane.

An optical glucose biosensor using a swim bladder membrane as an enzyme immobilization platform and an oxygen-sensitive membrane as an optical oxygen transducer has been developed. During the enzymatic reaction, glucose is oxidized by glucose oxidase with a concomitant consumption of dissolved oxygen resulting in an increase in the fluorescence intensity of the optical oxygen transducer. The fluorescence intensity is directly related to the glucose concentration. The effects of pH, temperature, buffer concentration, and selectivity have been studied in detail. The immobilized enzyme retained 80% of its initial activity after being kept for more than 10 months at 4 degrees C. The glucose biosensor has been successfully applied to the determination of glucose content in human blood serum and urine samples.

Air Sacs↗

A fluorescent glucose biosensor based on immobilized glucose oxidase on bamboo inner shell membrane.

A fluorescent glucose biosensor was constructed by immobilizing glucose oxidase on a bamboo inner shell membrane with glutaraldehyde as a cross-linker. The detection scheme was based on the depletion of dissolved oxygen content upon exposure to glucose solution with a concomitant increase in the fluorescence intensity of an oxygen transducer, tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(Pi) ditetrakis(4-chlorophenyl)borate. The enzyme immobilization, effect of pH, temperature and ionic strength have been studied in detail. The biosensor exhibited repeatable response to a 2.0 mM glucose solution with a relative standard deviation of 3.0% (n = 10). It showed good storage stability and maintained 95% of its initial response after it had been kept at 4 degrees C for 8 months. The biosensor has a linear response range of 0.0-0.6 mM glucose with a detection limit of 58 microM (S/N = 3). Common potential interferants in samples do not pose any significant interference on the response of the glucose biosensor. It was successfully applied to the determination of glucose content in some commercial wines and medical glucose injections.

Biosensing Techniques↗

An organic-phase optical phenol biosensor coupling enzymatic oxidation with chemical reduction.

This paper presents a recycle amplification optical biosensor to monitor phenol in hydrophobic organic solvents. Tyrosinase was first immobilised by entrapping it in a copolymer membrane of poly(vinyl alcohol)-hydroxyethyl carboxymethylcellulose doped with octadecylsilica particles. The biosensor was then constructed by co-mixing small particles of the immobilised tyrosinase with the adduct of L-ascorbic acid-poly(vinyl alcohol) (AsA-PVA) in conjunction with an optical oxygen transducer. The biosensor was characterised by its amplifying response to phenol, stable biocatalytic activity of entrapped-tyrosinase, free of interference from o-quinone polymerisation, and large water buffer capacity in hydrophobic organic solvents. The working range of the biosensor to phenol was 0.08-40 mmol dm(-3) in the flow mode. The response times (95%) of the biosensor were 4-7 min for phenol. The operational lifetime was more than 40 assays and the shelf lifetime of the biosensor was longer than 3 months. The biosensor has been successfully applied to quantify the phenol contents in some commercial ointment samples.

Biosensing Techniques↗

Spongiform immobilization architecture of ionotropy polymer hydrogel coentrapping alcohol oxidase and horseradish peroxidase with octadecylsilica for optical biosensing alcohol in organic solvent.

An organic-phase optical alcohol biosensor consisting of alcohol oxidase and horseradish peroxidase coimmobilized in a spongiform hydrogel matrix of hydroxethyl carboxymethyl cellulose, an adduct of 3-methoxy-4-ethoxy benzaldehyde, 4-tert-butylpyridinium acetohydrazone, silica gel particles, and octadecylsilica particles in conjunction with an optical oxygen transducer has been successfully fabricated. The novel enzyme entrapment structure was mainly characterized with desirable solvent permeability, high efficiency of mass transfer for reactants, and good accessibility and stability of the immobilized enzymes. The biosensor could work in water-miscible solvent such as a solvent mixture of acetonitrile and phosphate aqueous buffer, as well as hydrophobic organic solvent such as n-hexane. The biosensor had the highest sensitivity to methanol in both solvent systems. Under the stop-flow mode, the biosensor had the analytical working ranges from 80 microM to 90 mM methanol in n-hexane and 0.10 to 90 mM methanol in acetonitrile/buffer. When the biosensor functioned in n-hexane, it could take benzaldehyde as an alcohol substrate and was free from any pH disturbance. In the presence of coimmobilized horseradish peroxidase, the operational life of the biosensor was 60 assays and the shelf life was longer than two weeks. The biosensor has been satisfactorily applied to the determination of methanol in commercial gasoline-methanol blend samples.

Alcohol Oxidoreductases↗

Investigation on DNA assembly to neutral red-cyclodextrin complex by molecular spectroscopy.

DNA assembling to neutral red (NR) and cyclodextrins (CDs)-NR inclusion complex has been investigated by means of absorption, fluorescence and resonance light scattering (RLS). Depending on the molar ratio R of NR:DNA, the binding of NR with DNA involved in two processes at pH 7.50 and ionic strength 0.0045. The first process occurs in R>2.5, where the neutral form of NR was predominant and enhanced RLS was observed, indicating the aggregation of NR neutral form molecules on the molecular surface of DNA. The second process occurs in R<2.5, where an absorption band at 540 nm and a fluorescent excitation and emission band at 550 and 607 nm respectively provided compelling evidence that the binding of NR to DNA leaded to extensive NR protonation even at pH 7.50, and that a protonated NR (the acidic form of NR) can form DNA adducts with a binding mode different from that of the unprotonated form (the neutral form of NR). The results were also illustrated by the CDs-NR supramolecular system. The experimental data showed that CDs including beta-CD, hydroxypropyl-beta-CD (HP-beta-CD) and sulfobutylether-beta-CD (SBE-beta-CD) superior to include the neutral form of NR, in addition, the inclusion complex decomposed when it bound to DNA. Thus, the decomposed NR was also protonated to form DNA adducts with intercalative mode. In fact, CDs played a role to carry guest molecule to intercalate DNA. A related mechanism is proposed.

Absorption↗

Hydrogel network entrapping cholesterol oxidase and octadecylsilica for optical biosensing in hydrophobic organic or aqueous micelle solvents.

Two optical cholesterol biosensors have been fabricated by immobilizing cholesterol oxidase (ChOx) and octadecylsilica (ODS) particles in hydrogel network matrixes of copolymer of poly(vinyl alcohol) (PVA)/hydroxyethyl carboxymethyl cellulose (HECMC), and sol-gel, respectively. In conjunction with an optical oxygen transducer, the immobilized ChOx in the sol-gel/ODS matrix was assembled as an optical cholesterol biosensor to continuously detect free cholesterol in aqueous micelle solution, while the immobilized ChOx in the PVA/HECMC/ODS matrix was constructed as an organic-phase optical cholesterol biosensor for the continuous analysis of free cholesterol in hydrophobic organic solvent. The compositions and properties of the immobilization matrixes, the effects of solvents and the analytical features were studied in detail. Both biosensors showed stable and reliable responses toward free cholesterol. For the aqueous micelle cholesterol biosensor, the analytical working range was from 0.05 to 8.0 mM cholesterol, the response time was 7-12 min, the operation life was more than 35 assays, and the shelf life was approximately 4 months. For the organic-phase cholesterol biosensor, the analytical working range was from 0.07 to 18.0 mM cholesterol, the response time was 4-8 min, the operation life was more than 120 assays, and the shelf life was longer than 5 months. The organic-phase cholesterol biosensor has been successfully applied to determine the free cholesterol content in commercial butter samples.

Biosensing Techniques↗

Mixed C18 and C1 modification on an optical fiber for chromatographic sensing.

An optical fiber-chromatographic sensor, aiming at simultaneous and selective response to multiple components following a chromatographic separation, is described. We report an improved approach for immobilization of octadecyl (C(18)) and methyl (C(1)) moieties as stationary phase on an optical fiber suitable as a sensing phase for organic solutes. By this approach, the stability and lifetime of the sensing layer as well as the detectability and retention behavior of the chromatographic sensor could be improved. Infrared spectroscopy was employed to confirm the presence of C(18) and C(1) moieties on the modified surface of the optical fiber. The chromatographic sensor was applied, with good sensitivity and chemical selectivity, to the simultaneous separation and detection of bromobenzene and toluene, using water as the mobile phase.

Biosensing Techniques↗

Aspartame optical biosensor with bienzyme-immobilized eggshell membrane and oxygen-sensitive optode membrane.

An aspartame optical biosensor has been fabricated by employing a bienzyme system composed of alpha-chymotrypsin and alcohol oxidase immobilized onto an eggshell membrane and an oxygen-sensitive optode membrane as the transducer. The detection schemes involve the enzymatic reactions of aspartame leading to the depletion of the oxygen level of the medium with a concomitant enhancement of the fluorescence intensity of the oxygen-sensitive membrane. The scanning electron and transmission electron micrographs show the microstructure of the eggshell membrane which is successfully immobilized with bienzyme. Using this novel immobilization technique, the aspartame biosensor shows extremely good stability with a shelf life of at least 8 months. The rate change of the fluorescence intensity in 4 min is found to be linearly related to the concentration of aspartame. The useful analytical working range of the biosensor is from 0.056 to 3.07 mM aspartame. The effects of temperature, pH, and ionic strength on the response of the aspartame biosensor are investigated in detail. Citric acid, cyclamic acid, D-fructose, D-galactose, D-glucose, hydrogen peroxide, DL-malic acid, L-phenylalanine, saccharin, sodium benzoate, and sucrose show no interferences but ethanol interferes strongly. The aspartame biosensor has been applied to determine aspartame contents in some commercial products.

Animals↗