PubMed Health⌕ Search

Biomedical subjects

Mary E Dickinson

Publications and source records attributed to Mary E Dickinson.

13 recordsLinked to original sources

Uncovering phenotypic expansion in AXIN2-related disorders through precision animal modeling.

PURPOSE: Heterozygous pathogenic variants in AXIN2 (HGNC: 904) cause oligodontia-colorectal cancer syndrome. We identified 5 individuals with de novo heterozygous variants [NM_004655.4:c.196G>A p.(Glu66Lys), c.197A>G p.(Glu66Gly), and c.199G>A p.(Gly67Arg)] in AXIN2. Common phenotypes among these individuals included ectodermal dysplasia, global developmental delay, microcephaly, and limb, ophthalmologic, and genitourinary abnormalities. METHODS: Structural modeling was performed to predict the impact of these variants on AXIN2. A prime editing N1 screen of mouse embryos was performed to test whether the p.Glu66Lys variant produces a phenotype. Drosophila models were used to test the effect of this variant on Wnt signaling. RESULTS: Structural modeling suggests that these variants disrupt AXIN2 binding to tankyrase, which regulates AXIN2 levels through poly-ADP-ribosylation. Heterozygous (p.Glu66Lys) mouse embryos were perinatally lethal with soft palate clefts and skeletal abnormalities. Modeling of the p.Glu66Lys variant in the Drosophila wing suggests gain-of-function or dominant-negative activity compared to reference AXIN2. CONCLUSION: Specific variants in the tankyrase-binding domain of AXIN2 are pathogenic, leading to phenotypic expansion with potential context-dependent effects on AXIN2 function and Wnt signaling. The N1 modeling strategy used to demonstrate variant pathogenicity may be beneficial for resolving other heterozygous variants associated with congenital anomalies.

AXIN2↗

Moving toward the light: using new technology to answer old questions.

Fluorescence microscopy has become a principle methodology in the field of developmental biology. Recent technological advances have led to the design of high-speed and high-resolution confocal and multiphoton microscopes that enable researchers to obtain three- and four-dimensional information in living cells and whole embryos. Paralleling this progress, the development of stable and bright vital fluorescent probes has revolutionized the ability to track individual cells in vitro and in vivo and to visualize intercellular and subcellular molecular interactions in real time. Combining imaging modalities and labeling techniques that are increasingly unobtrusive to cell and whole animal function, our understanding of how proteins interact, tissues take form, and organs synchronize to create a functioning animal is reaching a whole new level.

Animals↗

The embryonic vertebrate heart tube is a dynamic suction pump.

The embryonic vertebrate heart begins pumping blood long before the development of discernable chambers and valves. At these early stages, the heart tube has been described as a peristaltic pump. Recent advances in confocal laser scanning microscopy and four-dimensional visualization have warranted another look at early cardiac structure and function. We examined the movement of cells in the embryonic zebrafish heart tube and the flow of blood through the heart and obtained results that contradict peristalsis as a pumping mechanism in the embryonic heart. We propose a more likely explanation of early cardiac dynamics in which the pumping action results from suction due to elastic wave propagation in the heart tube.

Animals↗

Dishevelled genes mediate a conserved mammalian PCP pathway to regulate convergent extension during neurulation.

The planar cell polarity (PCP) pathway is conserved throughout evolution, but it mediates distinct developmental processes. In Drosophila, members of the PCP pathway localize in a polarized fashion to specify the cellular polarity within the plane of the epithelium, perpendicular to the apicobasal axis of the cell. In Xenopus and zebrafish, several homologs of the components of the fly PCP pathway control convergent extension. We have shown previously that mammalian PCP homologs regulate both cell polarity and polarized extension in the cochlea in the mouse. Here we show, using mice with null mutations in two mammalian Dishevelled homologs, Dvl1 and Dvl2, that during neurulation a homologous mammalian PCP pathway regulates concomitant lengthening and narrowing of the neural plate, a morphogenetic process defined as convergent extension. Dvl2 genetically interacts with Loop-tail, a point mutation in the mammalian PCP gene Vangl2, during neurulation. By generating Dvl2 BAC (bacterial artificial chromosome) transgenes and introducing different domain deletions and a point mutation identical to the dsh1 allele in fly, we further demonstrated a high degree of conservation between Dvl function in mammalian convergent extension and the PCP pathway in fly. In the neuroepithelium of neurulating embryos, Dvl2 shows DEP domain-dependent membrane localization, a pre-requisite for its involvement in convergent extension. Intriguing, the Loop-tail mutation that disrupts both convergent extension in the neuroepithelium and PCP in the cochlea does not disrupt Dvl2 membrane distribution in the neuroepithelium, in contrast to its drastic effect on Dvl2 localization in the cochlea. These results are discussed in light of recent models on PCP and convergent extension.

Adaptor Proteins, Signal Transducing↗

Multimodal imaging of mouse development: tools for the postgenomic era.

With the sequence of the mouse genome known, it is now possible to create or identify mutations in every gene to determine the molecules necessary for normal development. Consequently, there is a growing need for advanced phenotyping tools to best understand defects produced by altering gene function. Perhaps nothing is more satisfying than to directly observe a process in action; to disturb it and see for ourselves how the process changes before our very eyes. No doubt, this desire is what drove the invention of the very first microscopes and continues to this day to fuel progress in the field of biological imaging. Because mouse embryos are small and develop embedded within many tissue layers within the nurturing environment of the mother, directly observing the dynamic, micro- and nanoscopic events of early mammalian development has proven to be one of the greater challenges for imaging scientists. Here, I will review some of the imaging methods being used to study mouse development, highlighting the results obtained from imaging.

Animals↗

Rapid three-dimensional imaging and analysis of the beating embryonic heart reveals functional changes during development.

We report an accurate method for studying the functional dynamics of the beating embryonic zebrafish heart. The fast cardiac contraction rate and the high velocity of blood cells have made it difficult to study cellular and subcellular events relating to heart function in vivo. We have devised a dynamic three-dimensional acquisition, reconstruction, and analysis procedure by combining (1) a newly developed confocal slit-scanning microscope, (2) novel strategies for collecting and synchronizing cyclic image sequences to build volumes with high temporal and spatial resolution over the entire depth of the beating heart, and (3) data analysis and reduction protocols for the systematic extraction of quantitative information to describe phenotype and function. We have used this approach to characterize blood flow and heart efficiency by imaging fluorescent protein-expressing blood and endocardial cells as the heart develops from a tube to a multichambered organ. The methods are sufficiently robust to image tissues within the heart at cellular resolution over a wide range of ages, even when motion patterns are only quasiperiodic. These tools are generalizable to imaging and analyzing other cyclically moving structures at microscopic scales.

Animals↗

Using a histone yellow fluorescent protein fusion for tagging and tracking endothelial cells in ES cells and mice.

We report the first endothelial lineage-specific transgenic mouse allowing live imaging at subcellular resolution. We generated an H2B-EYFP fusion protein which can be used for fluorescent labeling of nucleosomes and used it to specifically label endothelial cells in mice and in differentiating embryonic stem (ES) cells. A fusion cDNA encoding a human histone H2B tagged at its C-terminus with enhanced yellow fluorescent protein (EYFP) was expressed under the control of an Flk1 promoter and intronic enhancer. The Flk1::H2B-EYFP transgenic mice are viable and high levels of chromatin-localized reporter expression are maintained in endothelial cells of developing embryos and in adult animals upon breeding. The onset of fluorescence in differentiating ES cells and in embryos corresponds with the beginning of endothelial cell specification. These transgenic lines permit real-time imaging in normal and pathological vasculogenesis and angiogenesis to track individual cells and mitotic events at a level of detail that is unprecedented in the mouse.

Aging↗

Dynamic in vivo imaging of mammalian hematovascular development using whole embryo culture.

The yolk sac is the initial site of hematopoiesis in the mammalian embryo. As the embryo develops, blood vessels form around primitive erythroblasts to connect the yolk sac to the embryo, delivering newly formed blood cells to the embryonic circulation. The limited accessibility of the mammalian embryo has made it difficult to study the dynamic changes in cellular development during the formation of the early hematovascular system. Therefore, we have developed a culture system for studying early hematopoiesis, vasculogenesis. and angiogenesis in the mouse embryo. Early embryos (E7.5-E9.5) can be grown on the microscope stage to study the dynamics as vessels form and circulation begins. In addition, this mouse embryo culture system provides an excellent model for understanding the interplay between flow dynamics and cellular development.

Animals↗

Assembly of alpha4beta2 nicotinic acetylcholine receptors assessed with functional fluorescently labeled subunits: effects of localization, trafficking, and nicotine-induced upregulation in clonal mammalian cells and in cultured midbrain neurons.

Fura-2 recording of Ca2+ influx was used to show that incubation in 1 microm nicotine (2-6 d) upregulates several pharmacological components of acetylcholine (ACh) responses in ventral midbrain cultures, including a MLA-resistant, DHbetaE-sensitive component that presumably corresponds to alpha4beta2 receptors. To study changes in alpha4beta2 receptor levels and assembly during this upregulation, we incorporated yellow and cyan fluorescent proteins (YFPs and CFPs) into the alpha4 or beta2 M3-M4 intracellular loops, and these subunits were coexpressed in human embryonic kidney (HEK) 293T cells and cultured ventral midbrain neurons. The fluorescent receptors resembled wild-type receptors in maximal responses to ACh, dose-response relations, ACh-induced Ca2+ influx, and somatic and dendritic distribution. Transfected midbrain neurons that were exposed to nicotine (1 d) displayed greater levels of fluorescent alpha4 and beta2 nicotinic ACh receptor (nAChR) subunits. As expected from the hetero-multimeric nature of alpha4beta2 receptors, coexpression of the alpha4-YFP and beta2-CFP subunits resulted in robust fluorescence resonance energy transfer (FRET), with a FRET efficiency of 22%. In midbrain neurons, dendritic alpha4beta2 nAChRs displayed greater FRET than receptors inside the soma, and in HEK293T cells, a similar increase was noted for receptors that were translocated to the surface during PKC stimulation. When cultured transfected midbrain neurons were incubated in 1 microm nicotine, there was increased FRET in the cell body, denoting increased assembly of alpha4beta2 receptors. Thus, changes in alpha4beta2 receptor assembly play a role in the regulation of alpha4beta2 levels and responses in both clonal cell lines and midbrain neurons, and the regulation may result from Ca2+-stimulated pathways.

Animals↗

Technicolour transgenics: imaging tools for functional genomics in the mouse.

Over the past decade, a battery of powerful tools that encompass forward and reverse genetic approaches have been developed to dissect the molecular and cellular processes that regulate development and disease. The advent of genetically-encoded fluorescent proteins that are expressed in wild type and mutant mice, together with advances in imaging technology, make it possible to study these biological processes in many dimensions. Importantly, these technologies allow direct visual access to complex events as they happen in their native environment, which provides greater insights into mammalian biology than ever before.

Animals↗

Multiphoton excitation spectra in biological samples.

Multiphoton microscopy is becoming a popular mode of live and fixed cell imaging. This mode of imaging offers several advantages due to the fact that fluorochrome excitation is a nonlinear event resulting in excitation only at the plane of focus. Multiphoton excitation is enhanced by the use of ultrafast lasers emitting in the near IR, offering better depth penetration coupled with efficient excitation. Because these lasers, such as titanium:sapphire lasers, offer tunable output it is possible to use them to collect multiphoton excitation spectra. We use the software-tunable Coherent Chameleon laser coupled to the Zeiss LSM 510 META NLO to acquire x-y images of biological samples at multiple excitation wavelengths, creating excitation lambda stacks. The mean intensity of pixels within the image plotted versus excitation wavelength reveals the excitation spectra. Excitation lambda stacks can be separated into individual images corresponding to the signal from different dyes using linear unmixing algorithms in much the same way that emission fingerprinting can be used to generate crosstalk free channels from emission lambda stacks using the META detector. We show how this technique can be used to eliminate autofluorescence and to produce crosstalk-free images of dyes with very close overlap in their emission spectra that cannot be separated using emission fingerprinting. Moreover, excitation finger- printing can be performed using nondescanned detectors (NDDs), offering more flexibility for eliminating autofluorescence or crosstalk between fluorochromes when imaging deep within the sample. Thus, excitation fingerprinting complements and extends the functions offered by the META detector and emission fingerprinting. We correct biases in the laser and microscope transmission to acquire realistic multiphoton excitation spectra for fluorochromes within cells using the microscope, which enables the optimization of the excitation wavelength for single and multilabel experiments and provides a means for studying the influence of the biological environment on nonlinear excitation.

3T3 Cells↗

Using electroporation and lipid-mediated transfection of GFP-expressing plasmids to label embryonic avian cells for vital confocal and two-photon microscopy.

Fluorescent proteins have emerged as an ideal fluorescent marker for studying cell morphologies in vital systems. These proteins were first applied in whole organisms with established germ-line transformation protocols, but now it is possible to label cells with fluorescent proteins in other organisms. Here we present two ways to introduce GFP expressing plasmids into avian embryos for vital confocal and two-photon imaging. First, electroporation is a powerful approach to introduce GFP into the developing neural tube, offering several advantages over dye labeling. Second, we introduce a new lipid-based transfection system for introducing plasmid DNA directly to a small group of injected cells within live, whole embryos. These complementary approaches make it possible to transfect a wide-range of cell types in the avian embryo and the bright, stable, uniform expression of GFP offers great advantages for vital fluorescence imaging.

Animals↗

Four-dimensional cardiac imaging in living embryos via postacquisition synchronization of nongated slice sequences.

Being able to acquire, visualize, and analyze 3D time series (4D data) from living embryos makes it possible to understand complex dynamic movements at early stages of embryonic development. Despite recent technological breakthroughs in 2D dynamic imaging, confocal microscopes remain quite slow at capturing optical sections at successive depths. However, when the studied motion is periodic--such as for a beating heart--a way to circumvent this problem is to acquire, successively, sets of 2D+time slice sequences at increasing depths over at least one time period and later rearrange them to recover a 3D+time sequence. In other imaging modalities at macroscopic scales, external gating signals, e.g., an electro-cardiogram, have been used to achieve proper synchronization. Since gating signals are either unavailable or cumbersome to acquire in microscopic organisms, we have developed a procedure to reconstruct volumes based solely on the information contained in the image sequences. The central part of the algorithm is a least-squares minimization of an objective criterion that depends on the similarity between the data from neighboring depths. Owing to a wavelet-based multiresolution approach, our method is robust to common confocal microscopy artifacts. We validate the procedure on both simulated data and in vivo measurements from living zebrafish embryos.

Algorithms↗