PubMed Health⌕ Search

Biomedical subjects

Mary E Robbins

Publications and source records attributed to Mary E Robbins.

6 recordsLinked to original sources

Planar nitric oxide (NO)-selective ultramicroelectrode sensor for measuring localized NO surface concentrations at xerogel microarrays.

A planar ultramicroelectrode nitric oxide (NO) sensor was fabricated to measure the local NO surface concentrations from NO-releasing microarrays of varying geometries. The sensor consisted of platinized Pt (25 microm) working electrode and a silver paint reference electrode coated with a thin silicone rubber gas permeable membrane. An internal hydrogel layer separated the Pt working electrode and gas permeable membrane. The total diameter of the sensor was <or=50 microm, and demonstrated negligible analyte trapping effects. The sensitivity and response time of the ultramicroelectrode sensor to NO were 0.19+/- 0.07 pA nM(-1) and 1-4 s, respectively, with a 5 nM limit of detection. The sensor was employed to correlate the steady-state NO surface concentration and observed platelet adhesion resistance. Results indicate that the required steady-state NO concentration necessary to inhibit platelet adhesion to the micro-patterned xerogels depends on the xerogel geometry.

Animals↗

Miniaturized glucose biosensor modified with a nitric oxide-releasing xerogel microarray.

An enzyme-based glucose biosensor modified to release nitric oxide (NO) via a xerogel microarray is reported. The biosensor design is as follows: (1) glucose oxidase (GOx) is immobilized in a methyltrimethoxysilane (MTMOS) xerogel layer; (2) a blended polyurethane/hydrophilic polyurethane coating prevents enzyme leaching and imparts selectivity for glucose; and (3) micropatterned xerogel lines (5 microm wide) separated by distances of 5 or 20 microm provide NO-release capability. This configuration allows for increased glucose sensitivity relative to sensors modified with NO-releasing xerogel films since significant portions of the sensor surface remain unmodified. Glucose diffusion to the GOx layer is thus less inhibited. The micropatterned NO-releasing biosensors generate sufficient NO levels to reduce both Pseudomonas aeruginosa and platelet adhesion without significantly compromising the enzymatic activity of GOx. The glucose response, linearity and stability of the NO-releasing micropatterned sensors are reported.

Absorption↗

Sol-gel derived nitric oxide-releasing oxygen sensors.

An amperometric sol-gel derived sensor that both releases nitric oxide (NO) and measures physiologically relevant concentrations of oxygen (PO2) is described. The sensor consists of a platinum electrode coated with an aminosilane/ethyltrimethoxysilane hybrid xerogel film. Hydrophilic polyurethane (HPU) is doped into the hybrid film to reduce sensor hydration time and increase oxygen permeability. Diazeniumdiolate NO donors are formed within the polymer matrix by exposing the cured film to high pressures of NO. These coatings release up to 7.2 pmol s(-1) cm(-2) of NO over the first 12 h and maintain detectable levels of NO release through 48 h. Sensors modified with HPU-doped, NO-releasing xerogels exhibit a linear response to O2 within 30 min of polarization at -0.65 V vs. Ag/AgCl, and have a sensitivity of approximately 6 nA/mmHg O2. The xerogel coating is stable in buffer solution with minimal fragmentation over 48 h. In vitro biocompatibility studies indicate that these materials effectively reduce platelet adhesion.

Animals↗

Synthesis and characterization of nitric oxide-releasing sol-gel microarrays.

Diazeniumdiolate-modified sol-gel microarrays capable of releasing low levels of nitric oxide are reported as a viable means for improving the blood compatibility of a surface without fully modifying the underlying substrate. Several parameters are characterized including: (1) NO surface flux as a function of sol-gel composition and microarray geometry; (2) microstructure dimensions and spacing for optimal blood compatibility; and (3) the effect of sol-gel surface modification on analyte accessibility to platinum electrodes. The sol-gel microarrays release biologically relevant levels of NO under physiological conditions for >24 h. In vitro platelet adhesion assays indicate that a NO surface flux of 2.2 pmol cm(-2) s(-1) effectively reduces platelet adhesion to glass substrates modified with sol-gel microstructures separated by 50 microm. The blood compatibility observed for these micropatterned surfaces is comparable to NO-releasing sol-gel films. When the separation between NO-releasing microstructures is reduced to 10 microm, the NO surface flux required to reduce platelet adhesion is lowered to 0.4 pmol cm(-2) s(-1). Finally, the oxygen response of platinum electrodes modified with NO-releasing sol-gel microarrays indicates that selective modification via micropatterning enhances analyte accessibility to the sensor surface.

Biocompatible Materials↗

Evidence that rehydrated, lyophilized red blood cells are sufficiently deformable for normal microcirculation transit.

A method was developed for the preparation of rehydratable lyophilized red blood cells (RL RBCs) that hold promise as cell-based oxygen carriers for transfusion medicine. The maintenance of normal cellular deformability is essential for the successful development of cell-based oxygen delivery systems. Improper deformability of RBCs can lead to hemolysis if too fragile or microvascular occlusion if too rigid. We developed an aldehyde stabilization method that is based on the use of paraformaldehyde polymers that complement the function of spectrin as a structural unit with conformational flexibility. Three types of in vitro deformability studies (filter transit, pipette aspiration, and atomic force microscopy) and in vivo intravital microscopy were performed to characterize the deformability of RL RBCs. When considered with safety data from previously reported studies in dogs, the results of these studies indicate that paraformaldehyde-modified RL RBCs have visco-elastic deformability properties that are in the nonpathological range.

Aldehydes↗

Surface-localized release of nitric oxide via sol-gel chemistry.

The release of nitric oxide (NO) from polymers has proven to be highly effective at inhibiting platelet adhesion and thus enhancing the blood compatibility of medical implants. Micropatterning techniques were used to design surfaces that release NO while preserving the underlying substrate for other applications (e.g., sensors). Micropatterned NO-releasing substrates based on aminosilane-containing methyltrimethoxysilane sol-gels were prepared and characterized in terms of stability, NO surface flux, and resistance to in vitro platelet adhesion. We have found that surface-localized NO release from substrates modified with sol-gel micropatterns exhibit enhanced blood compatibility relative to controls.

Animals↗