PubMed Health⌕ Search

Biomedical subjects

Marye J Gleva

Publications and source records attributed to Marye J Gleva.

13 recordsLinked to original sources

Relation of left ventricular lead placement in cardiac resynchronization therapy to left ventricular reverse remodeling and to diastolic dyssynchrony.

The effects of left ventricular (LV) lead placement for cardiac resynchronization therapy (CRT) on LV remodeling and dyssynchrony are not well defined. Sixty-one patients (age 60 +/- 11 years, 76% men) were evaluated by echocardiography before and 4 +/- 2 months after CRT and grouped by the LV lead placement (lateral, posterolateral, or anterolateral). Echocardiographic measurements included LV volumes and LV ejection fraction. Tissue Doppler imaging was used to assess for inter- and intraventricular systolic and diastolic dyssynchrony. Analysis of variance was used to determine the effect of the LV lead placement on echocardiographic variables after CRT. The LV lead was placed in a lateral cardiac vein in 33 patients (54%), posterolateral in 15 (25%), and anterior in 13 (21%). Lateral LV lead placement was associated with significantly smaller LV volumes compared with the posterolateral lead placement (p <0.01). Diastolic dyssynchrony improved significantly with lateral lead placement compared with the anterior lead location (p <0.05). Improvement in LV ejection fraction and inter- and intraventricular systolic dyssynchrony was similar among the 3 groups. In conclusion, in patients undergoing CRT, a lateral lead location resulted in greater reverse LV remodeling and improved diastolic dyssynchrony compared with other lead placement locations.

Diastole↗

Clinical outcomes after cardiac resynchronization therapy: importance of left ventricular diastolic function and origin of heart failure.

BACKGROUND: Cardiac resynchronization therapy (CRT) improves functional outcomes in patients with severe systolic heart failure. Whether the effects of CRT on left ventricular (LV) diastolic function and clinical outcomes are influenced by the cause as either ischemic or nonischemic cardiomyopathy (CM) has not been well established. METHODS: A total of 57 patients (age 60 +/- 11 years; 25% women; LV ejection fraction 25 +/- 5%) were studied before and 4 +/- 2 months after CRT by echocardiography. Heart failure cause was ischemic CM in 19 and nonischemic CM in 38. Measurements of LV systolic and diastolic function were determined by 2-dimensional and Doppler echocardiography with Doppler tissue imaging of regional myocardial velocities. Clinical outcome events were assessed at long-term follow-up and included hospitalization for heart failure exacerbation, heart transplantation, or cardiac-related death. RESULTS: There were significant increases in LV ejection fraction, reductions in end-systolic volumes, and improved LV systolic dyssynchrony in both groups. However, significant improvements in LV diastolic function were observed only in the patients with nonischemic CM. Clinical events occurred in 53% of the ischemic group versus 26% of the nonischemic group (P < .05) after 20 +/- 11 months of CRT. Univariate and multivariate analysis revealed that Doppler-estimated LV filling pressures were predictors of clinical outcome events. CONCLUSIONS: After CRT patients with ischemic CM exhibit lack of improvement in LV diastolic function despite favorable effects on LV systolic performance. The Doppler-derived LV filling indices may be an important predictor of long-term clinical outcomes after CRT.

Cardiac Pacing, Artificial↗

Radiofrequency ablation of atrioventricular nodal reentrant tachycardia using a novel magnetic guidance system compared with a conventional approach.

BACKGROUND: A novel magnetic guidance system has been developed that allows the operator to remotely navigate an electrophysiology mapping/ablation catheter to precise locations in the heart for treatment of tachyarrhythmias. To date, this new technology has not been directly compared with the conventional approach. OBJECTIVE: To compare the use of the magnetic guidance system to the conventional approach for ablation of atrioventricular nodal reentry tachycardia. METHODS: Between November 2002 and October 2004, 28 patients with atrioventricular nodal reentry tachycardia treated with the magnetic guidance system were retrospectively compared with 28 matched control patients. RESULTS: Patients treated using the magnetic guidance system had similar procedure durations and fluoroscopy times compared with the matched controls. The only statistically significant difference between the groups was a longer time between insertion of the ablation catheter and placement of the first radiofrequency lesion in the magnetic guidance system cohort (23.3 +/- 12.0 vs. 10.5 +/- 13.9, p=0.001), possibly due to the research protocol. However, there was a trend toward a shorter total time that radiofrequency energy was applied in the magnetic guidance system cohort (5.2 +/- 4.5 vs. 8.0 +/- 7.2, p=0.087). There were no major complications or recurrences after at least 3 months of follow-up among the patients treated with the magnetic guidance system. CONCLUSION: The magnetic guidance system appears to have similar, and possibly improved, clinical efficacy compared with conventional catheter navigation for the treatment of atrioventricular nodal reentrant tachycardia.

Adolescent↗

Smokers are at markedly increased risk of appropriate defibrillator shocks in a primary prevention population.

BACKGROUND: Cigarette smoking is a known risk factor for sudden cardiac death (SCD). It is unknown whether smoking status affects implantable cardioverter-defibrillator (ICD) therapy. OBJECTIVE: The primary end point was appropriate ICD therapy according to smoking status. METHODS: A total of 105 consecutive patients who underwent ICD implantation for primary prevention of SCD were retrospectively analyzed. All patients had an abnormal response to programmed ventricular stimulation performed for nonsustained ventricular tachycardia in the setting of ischemic cardiomyopathy between January 1999 and December 2003. RESULTS: Among the 105 patients, 6 (37.5%) of 16 current smokers, 14 (25.9%) of 54 former smokers, and 2 (5.7%) of 35 of never smokers received an appropriate ICD therapy (P = .02). Kaplan-Meier analysis for survival free of appropriate ICD therapy comparing never smokers with both current smokers (P = .002) and former smokers (P = .01) demonstrated statistically significant differences by log rank over a mean follow-up of 21.8 +/- 13.7 months. Cox regression analysis found that current smoking was associated with an increased risk of appropriate therapy (hazard ratio 7.36; 95% confidence interval 1.42-38.10; P = .02) as was former smoking (hazard ratio 5.42; 95% confidence interval 1.20-24.47; P = .03). There was no difference in inappropriate therapy between groups (P = .12). CONCLUSIONS: Cigarette smoking is an independent predictor of appropriate ICD therapy in a primary prevention population. While outcomes differences among current smokers, former smokers, and never smokers are demonstrable, the effect of smoking cessation on ICD therapy requires further study.

Aged↗

Management of arterial injuries caused by laser extraction of indwelling venous pacemaker and defibrillator leads.

The use of laser technology for the removal of pacemaker and defibrillator leads has decreased the lead extraction time and improved the success rate for complete lead removal when compared to traditional techniques. However, this extraction method may be associated with significant complications. This report documents two cases of iatrogenic arteriovenous fistula created by laser lead extraction. Endovascular repair of these fistulas provides an effective and less invasive alternative to open repair.

Aged↗

Laser assistance for extraction of chronically implanted endocardial leads: infectious versus noninfectious indications.

BACKGROUND: Powered sheaths, including Excimer laser sheaths, were introduced for the removal of transvenous pacing and defibrillator leads. The purpose of this study was to develop an algorithm to better predict which patients are likely to benefit from these devices. METHODS: We reviewed 283 consecutive patients in whom a total of 500 leads (302 pacing and 198 defibrillator leads) were extracted over a 5-year period at our operative facilities. Laser assist was utilized whenever moderate traction failed. RESULTS: In 128 patients, 203 leads were removed for noninfectious indication. In 155 patients, 297 leads for infectious indications, including sepsis 22% (111), pocket infection 23% (115), and erosion 14% (71). Laser assistance was required for 6%+/- 5% (+/- 95% confidence interval) of septic leads, 51%+/- 7% of leads associated with erosion or pocket infection and 60%+/- 7% of noninfected leads (P = 0.001). Laser assistance was necessary more often for leads implanted >12 months (53%+/- 5%) than 12 months or less (6%+/- 5%) (P = 0.001) and for ventricular (52%+/- 6%) compared to atrial (35%+/- 7%) leads (P = 0.001). CONCLUSIONS: Chronically implanted leads (>12 months), especially noninfected leads and leads associated with erosion or pocket infection, should be referred for extraction with powered sheaths to ensure successful removal. However, leads that are associated with systemic sepsis can generally be removed without powered sheaths.

Adolescent↗

Improvements in left ventricular diastolic function after cardiac resynchronization therapy are coupled to response in systolic performance.

OBJECTIVES: To determine the short-term effects of cardiac resynchronization therapy (CRT) on measurements of left ventricular (LV) diastolic function in patients with severe heart failure. BACKGROUND: Cardiac resynchronization therapy improves systolic performance; however, the effects on diastolic function by load-dependent pulsed-wave Doppler transmitral indices has been variable. METHODS: Fifty patients with severe heart failure were evaluated by two-dimensional Doppler echocardiography immediately prior to and 4 +/- 1 month after CRT. Measurements included LV volumes and ejection fraction (EF), pulsed-wave Doppler (PWD)-derived transmitral filling indices (E- and A-wave velocities, E/A ratio, deceleration time [DT], diastolic filling time [DFT], and isovolumic relaxation time). Tissue Doppler imaging was used for measurements of systolic and diastolic (Em) velocities at four mitral annular sites; mitral E-wave/Em ratio was calculated to estimate LV filling pressure. Color M-mode flow propagation velocities were also obtained. RESULTS: After CRT, LV volumes decreased significantly (p < 0.001) and LVEF increased >5% in 28 of 50 patients (56%) and were accompanied by reduction in PWD mitral E-wave velocity and E/A ratio (both p < 0.01), increased DT and DFT (both p < 0.01), and lower filling pressures (i.e., E-wave/Em septal; p < 0.01). Patients with LVEF response < or =5% after CRT had no significant changes in measurements of diastolic function; LV relaxation (i.e., Em velocities) worsened in this group. CONCLUSIONS: In heart failure patients receiving CRT, improvement in LV diastolic function is coupled to the improvement in LV systolic function.

Aged↗

Cardiac resynchronization therapy acutely improves diastolic function.

BACKGROUND: Invasive studies have shown that cardiac resynchronization therapy (CRT) acutely improves left ventricular (LV) systolic performance and lowers filling pressures in a majority of patients with medically-refractory severe heart failure. Measurements included LV volume, ejection fraction, PWD early (E-wave) and atrial (A-wave) velocities, diastolic filling time (DFT), and DTI early diastolic mitral annular velocity (Em) at the lateral and septal annulus; PWD mitral E-wave/Em and E/FP were calculated to estimate LV filling pressures. RESULTS: Immediately after CRT, LV volumes decreased and LVEF increased significantly. PWD mitral E-wave velocity decreased and E-wave duration and DFT increased significantly; mitral E/FP ratio also decreased significantly, consistent with a decrease in LV filling pressure. Patients with a pre-CRT mitral E/A ratio >1 (n = 20), demonstrated improvements in LV diastolic filling and lower filling pressures whereas those with an E/A ratio < or =1 (n = 21) did not show significant changes in diastolic indices. CONCLUSIONS: The acute effects of CRT include echocardiographic evidence of reduced LV volumes and increased LVEF with improved diastolic filling and lower filling pressures; LV relaxation is not significantly altered. The benefits in diastolic function are dependent on the PWD-determined LV filling characteristics prior to CRT.

Cardiac Pacing, Artificial↗

Implantable cardioverter-defibrillator therapy improves long-term survival in patients with unexplained syncope, cardiomyopathy, and a negative electrophysiologic study.

OBJECTIVES: The purpose of this study was to evaluate the long-term outcomes of patients with unexplained syncope, ischemic or nonischemic cardiomyopathy, and a negative electrophysiologic study (EPS). BACKGROUND: EPS is frequently performed to evaluate syncope in patients with left ventricular dysfunction. Limited long-term data evaluating all-cause mortality in patients with no inducible arrhythmia or examining the potential benefits from implantable cardioverter-defibrillator (ICD) therapy are available. METHODS: We evaluated 102 consecutive patients with unexplained syncope, cardiomyopathy, and a negative EPS from September 1996 to December 2000. A blinded matched case-control analysis utilized 51 of these patients (19 treated with an ICD and 32 matched controls treated with conventional therapy). We compared primary endpoint of death and documented cardiac arrest of patients treated with ICD therapy to matched controls. RESULTS: Baseline characteristics were similar between groups. There were 14 primary events among the study population during a follow-up period of 44.3 +/- 20 months: 2 in the ICD group and 12 in the conventional therapy group. The hazard ratio for the risk of event in the ICD group compared with the conventional therapy group was 0.18 (95% confidence interval, 0.04-0.85; P = .04). Other comorbid conditions, including age, sex, ischemic etiology of heart failure, ejection fraction, and antiarrhythmic use, did not predict outcome. Appropriate ICD shocks occurred in 26% of patients at 2 years. CONCLUSIONS: This study suggests that empiric ICD therapy improves long-term outcomes in patients with unexplained syncope, ischemic or nonischemic cardiomyopathy, and negative EPS.

Aged↗

Surgical treatment of atrial fibrillation: predictors of late recurrence.

OBJECTIVE: The Cox maze procedure was introduced in 1987 for the treatment of atrial fibrillation. This study evaluated the predictors of late atrial fibrillation recurrence in 276 consecutive patients who underwent this procedure at our institution. METHODS: From 1987 through June 2003, 276 patients (79 female and 197 male patients; mean age, 55 +/- 11 years) underwent the Cox maze procedure. Thirty-three patients had Cox maze procedure I, 16 patients had Cox maze procedure II, and 197 patients had Cox maze procedure III. The last 30 patients underwent a modified procedure (Cox maze procedure IV) with bipolar radiofrequency ablation. There were 113 (41%) patients who had a concomitant operation, most commonly either a mitral valve procedure (19%) or coronary artery bypass grafting (20%). Data were analyzed by means of univariate analysis, with preoperative and perioperative variables used as covariates. Patient follow-up was conducted by means of questionnaire, physician examination, and electrocardiographic documentation. All patients had a minimum of 6 months of follow-up. RESULTS: Patient follow-up was achieved in 92.8% of cases, with a mean follow-up time of 5.8 +/- 3.6 years. Risk factors for late atrial fibrillation recurrence were duration of preoperative atrial fibrillation (P = .01) and Cox maze procedure version (P = .001). There was no difference in actuarial 10-year survival between the Cox maze procedure versions. CONCLUSION: The Cox maze procedure remains the gold standard for the treatment of atrial fibrillation and has excellent long-term efficacy. The most significant predictor of late recurrence was duration of preoperative atrial fibrillation, suggesting that earlier surgical intervention would further increase efficacy.

Adult↗

Atrial tachyarrhythmias after the maze procedure: incidence and prognosis.

BACKGROUND: The Maze procedure restores normal sinus rhythm in the majority of patients. However, atrial tachyarrhythmias (ATA) are a common early complication after the operation. The purpose of this study was to define the incidence and natural history of ATA after the Maze procedure. METHODS: Complete medical records from 200 patients who underwent the Maze procedures (I, II, and III) from 1987 to 2002 were examined for all episodes of early postoperative ATA that occurred during the first 30 days after the procedure. Two electrophysiologists independently reviewed all postoperative 12-lead electrocardiograms. RESULTS: ATA occurred in 86 patients (43%) after the Maze procedure. Of the patients with ATA, 59% had atrial fibrillation (AF), 14% had atrial flutter (AFL), and 27% had both AF and AFL. Of the patients with AF or AFL, 20% and 5%, respectively, also had episodes of atrial tachycardia and supraventricular tachyarrhythmia. The peak incidence of early postoperative ATA was on postoperative day 8. The average duration of ATA was 5.7+/-5.0 days. Late recurrence of AF (>1 year postoperatively) occurred in 7.0% of patients who had early postoperative ATA and 8.8% of patients without early postoperative ATA (P=0.8). CONCLUSIONS: ATA occurred in 43% of patients after the Maze procedure. The tachyarrhythmias occurred primarily within 8 days after surgery and resolved within 3 weeks in almost all patients. There was no relationship between the incidence of early postoperative ATA and the late recurrence of AF.

Adult↗

Laser-assist during extraction of chronically implanted pacemaker and defibrillator leads.

BACKGROUND: Extraction of chronically implanted pacing and defibrillator leads has historically been difficult, occasionally requiring open surgical procedures. The purpose of this study was to evaluate the efficacy, safety, and potential need for percutaneous laser-assisted sheath techniques for extraction of chronically implanted leads. METHODS: From January 1999 to August 2001, 128 consecutive patients underwent extraction of 229 leads (138 pacing, 91 defibrillator) in the operating room 61 +/- 44 (mean +/- standard deviation) months after implantation. Common indications included erosion or pocket infection (41%), lead dysfunction (30%), and sepsis (13%). RESULTS: Laser techniques were used for 56% +/- 4% (104 of 186) of long-term (implanted for more than 1 year) leads, compared with only 16% +/- 6% (7 of 43) of short-term (implanted for less than 1 year) leads (p < 0.001). For infected leads, laser was used in 53% +/- 5% (49 of 92) with erosion or pocket infections, compared with only 3% +/- 4% (1 of 29) with sepsis (p < 0.001). Extraction was complete in 88%, near complete (retained tip) in 10%, and incomplete in 2%. Two patients required a later percutaneous femoral venous approach to remove mobile retained segments, but no patients required cardiac surgery for extraction. Complications included sternotomy for subclavian vein injury (1), chest tube for caval perforation (1), innominate vein thrombosis (1), and partial clavicle removal for subclavian vein repair (2). There were no procedure-related deaths. CONCLUSIONS: Laser-assisted lead extraction is safe, but it is best performed in the operating room; it should be available for long-term leads, except when they are grossly infected, producing sepsis. Laser techniques have essentially eliminated the need for open surgical removal of retained leads.

Adult↗