PubMed Health⌕ Search

Biomedical subjects

Masahide Itoh

Publications and source records attributed to Masahide Itoh.

6 recordsLinked to original sources

Fast calculation method for spherical computer-generated holograms.

The synthesis of spherical computer-generated holograms is investigated. To deal with the staggering calculation times required to synthesize the hologram, a fast calculation method for approximating the hologram distribution is proposed. In this method, the diffraction integral is approximated as a convolution integral, allowing computation using the fast-Fourier-transform algorithm. The principles of the fast calculation method, the error in the approximation, and results from simulations are presented.

Journal Article↗

Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography.

High-speed complex full-range Fourier domain optical coherence tomography (FD-OCT) is demonstrated. In this FD-OCT, the phase modulation of a reference beam (M scan) and transversal scanning (B scan) are simultaneously performed. The Fourier transform method is applied along the direction of the B scan to reconstruct complex spectra, and the complex spectra comprise a full-range OCT image. Because of this simultaneous B-M-mode scan, the FD-OCT requires only a single A scan for each single transversal position to obtain a full-range FD-OCT image. A simple but slow version of the FD-OCT visualizes the cross section of a plastic plate. A modified fast version of this FD-OCT investigates a sweat duct in a finger pad in vivo and visualizes it with an acquisition time of 27 ms.

Computer Systems↗

Polarization contrast imaging of biological tissues by polarization-sensitive Fourier-domain optical coherence tomography.

Jones matrix imaging of biological samples by a polarization-sensitive Fourier-domain optical coherence tomography has been demonstrated using a two-dimensional CCD camera to obtain two spectra corresponding to the orthogonal polarization components simultaneously. The measurement results of a quarter-wave plate are compared between the two incident polarization sets, H-V linear and R-L circular polarization. Jones matrix imaging of the bovine tendon is demonstrated. Measured Jones matrix images are converted to equivalent Müller matrix images. Local polarization properties are obtained by longitudinal differentiation of Jones matrix components. The layered structure of the bovine tendon and birefringence are revealed.

Algorithms↗

Holographic three-dimensional display synthesized from three-dimensional fourier spectra of real existing objects.

A method of synthesizing computer-generated holograms of real existing objects is proposed that is based on a series of projection images of an incoherently illuminated object recorded from different perspectives. In accordance with the principles of computer tomography, the three-dimensional Fourier spectrum of the object is calculated by use of several projection images. A method of calculating a Fresnel hologram from the three-dimensional Fourier spectrum is proposed. Experimental results in the form of a computer simulation and optical reconstruction are presented.

Journal Article↗

Treatment of nevus using medical tattooing.

Medical tattooing is used to color skin with a pigment loss. Currently, however, a trial-and-error scheme is employed to obtain the desired color appearance of tattooed skin because prediction of the color appearance is dependent on the experiences of medical doctors. We propose a method for predicting the color appearance of tattooed skin. Two trial dyes are first injected in the area of pigment loss, and the color appearance of a third dye to be injected can be predicted using measured spectrocolorimeter data and mathematical formula. The spectrocolorimeter measures the color appearances of the skin before and after tattooing using the first two dyes, and the mathematical formula calculates the color appearance of the tattooed skin using any third dye. In the derivation of the mathematical formula, light propagation in the skin has been modeled using the modified Lambert-Beer law considering the strong scattering of light by biological tissues. The proposed method was successfully validated by a preliminary tattooing of the skin to an area with pigment loss. Predicting the color appearance of tattooed skin significantly reduces the number of trial-and-error attempts required in the current methods. Medical tattooing using this method can also be applied to treat various skin color abnormalities such as leukoderma, intradermal nevi, and reconstructed nipples.

Colorimetry↗

Three-dimensional line-field Fourier domain optical coherence tomography for in vivo dermatological investigation.

We demonstrate 3-D optical coherence tomography using only 1-D mechanical scanning. This system uses the principle of Fourier domain optical coherence tomography for depth resolution, 1-D imaging for lateral vertical resolution, and mechanical scanning by a galvanometer for lateral horizontal resolution. An in vivo human fingerpad is investigated in three dimensions with an image size of 480 points (vertical) x 300 points (horizontal) x 1024 points (depth), which corresponds to 2.1 x 1.4 x 1.3 mm. The acquisition time for a single cross section is 1 ms and that for a single volume is 10 s. The system sensitivity is 75.6 dB at a probe beam power of 1.1 mW.

Dermoscopy↗