Immunoglobulin E-independent activation of mast cell is mediated by Mrg receptors.

Mast cells play a central role in inflammatory and allergic reactions by releasing inflammatory mediators through two main pathways, immunoglobulin E-dependent and -independent activation. In the latter, mast cells are activated by a diverse range of basic molecules, including peptides and amines such as substance P, neuropeptide Y, and compound 48/80. These secretagogues are thought to activate the G proteins in mast cells through a receptor-independent mechanism. Here, we report that the basic molecules activate G proteins through the Mas-related gene (Mrg) receptors on mast cells, leading to mast cell degranulation. We suggest that one of the Mrg receptors, MrgX2, has an important role in regulating inflammatory responses to non-immunological activation of human mast cells.

Animals↗

Two-dimensional HPLC on-line analysis of phosphopeptides using titania and monolithic columns.

Conventional and comprehensive two-dimensional (2D) HPLC systems using the combination of titania and monolithic columns were established for the on-line analysis of phosphopeptides. Compared with immobilized metal affinity chromatography of a general method for the analysis of phosphopeptides, the use of titania columns in the analysis permits the specific isolation of phosphopeptides in a higher yield. Using the current 2D HPLC systems, phosphopeptides were specifically isolated from nonphosphorylated peptides by the first-dimension titania column, followed by the high-speed separation of the phosphopeptides by the second-dimension monolithic column. Proteolytic digests of beta-casein were analyzed within 30 min using the comprehensive 2D HPLC system; all phosphopeptides from beta-casein could be efficiently isolated and identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The comprehensive 2D HPLC system coupled with mass spectrometry will be useful for high-throughput and on-line phosphoproteome analyses.

Caseins↗

Enhanced sequence coverage in tryptic fragment analysis by two-dimensional HPLC/MS using a monolithic silica capillary column.

The HPLC/MS system, in which a monolithic silica capillary column is directly connected to an electronspray-ionization mass spectrometer, showed superior performance at high mobile phase linear velocity. A two-dimensional (2D) HPLC/MS system was established, using an ion-exchange particle-packed capillary column at the first dimension and a monolithic silica capillary column at the second dimension. In an analysis of tryptic fragments from bovine serum albumin, an 81% sequence coverage, obtained by the 2D-HPLC/MS system, increased by 23% as compared to a 1D-HPLC/MS system. This 2D-HPLC/MS system using a monolithic silica capillary column should be useful for enhancing sequence coverage of tryptic fragments in proteomics.

Amino Acid Sequence↗

Development of miniaturized multi-channel high-performance liquid chromatography for high-throughput analysis.

We have developed miniaturized multi-channel high-performance liquid chromatography (HPLC) system. With this system, we can simultaneously separate multiple samples, using a single high-pressure gradient pump, a chip-based sample injection unit, a monolithic silica capillary column array, and a multi-channel UV detection unit based on fiber optics. The injection unit has a simplified structure composed of brass housing and a quartz microchip having microchannels and access ports, which enable a direct injection of sample to multi-channel by commercial multichannel micropipette. Moreover, that possesses a function of microvalve, and on-chip definition of sample injection plugs achieved with a cross channel injection method, providing each column of monolithic silica capillary array. The substances in channels were simultaneously detected with UV having multiple cells. Standard samples were analyzed for characterizing newly developed system, and sharp peaks were obtained with reproducibility data of < 0.9% (R.S.D.). Analysis of tryptic digestion of casein was also employed. These results show that the novel multi-channel HPLC system has the benefits for the high-throughput analysis in the post-genomic analysis/combinatorial chemistry.

Chromatography, High Pressure Liquid↗

Development of a monolithic silica extraction tip for the analysis of proteins.

In proteomics, pre-treatment of sample is the most important procedure to remove the matrix for interfacing with mass spectrometry (MS). Additionally, for the samples with low concentration, the process of pre-concentration is required before MS analysis. We have newly developed solid-phase extraction (SPE) tool with pipette-tip shape for purification of bio-samples of various characteristics, utilizing monolithic silica gel as medium. The monolithic silica surface was modified with a C18 phase or coated with titania phase. A C18-bonded tip and a non-modified tip were used for sample concentration, desaltination and removal of detergents from sample. A titania-coated tip was also applied for purification and concentration of phosphorylated peptides. This novel pre-treatment method using monolithic silica extraction tip is much effective and suitable for protein analysis.

Chromatography, High Pressure Liquid↗

Simple and comprehensive two-dimensional reversed-phase HPLC using monolithic silica columns.

Simple and comprehensive two-dimensional (2D)-HPLC was studied in a reversed-phase mode using monolithic silica columns for second-dimension (2nd-D) separation. Every fraction from the first column, 15 cm long (4.6-mm i.d.), packed with fluoroalkylsilyl-bonded (FR) silica particles, was subjected to the separation in the 2nd-D using one or two octadecylsilylated (C(18)) monolithic silica columns (4.6-mm i.d., 3 cm). Monolithic silica columns in the 2nd-D were eluted at a flow rate of up to 10 mL/min with separation time of 30 s that meets the fractionation every 15-30 s at the first dimension (1st-D) operated at a flow rate of 0.4-0.8 mL/min. Three cases were studied. (1) In the simplest scheme of 2D-HPLC, effluent of the 1st-D was directly loaded into an injector loop of 2nd-D HPLC for 28 s, and 2 s was allowed for injection. (2) Two six-port valves each having a sample loop were used to hold the effluent of the 1st-D alternately for 30 s for one 2nd-D column to effect comprehensive 2D-HPLC without the loss of 1st-D effluent. (3) Two monolithic silica columns were used for 2nd-D by using a switching valve and two sets of 2nd-D chromatographs separating each fraction of the 1st-D effluent with the two 2nd-D columns alternately. In this case, two columns of the same stationary phase (C(18)) or different phases, C(18) and (pentabromobenzyloxy)propylsilyl-bonded (PBB), could be employed at the 2nd-D, although the latter needed two complementary runs. The systems produced peak capacity of approximately 1000 in approximately 60 min in cases 1 and 2 and in approximately 30 min in case 3. The three stationary phases, FR, C(18), and PBB, showed widely different selectivity from each other, making 2D separations possible. The simple and comprehensive 2D-HPLC utilizes the stability and high efficiency at high linear velocities of monolithic silica columns.

Journal Article↗

Phosphopeptide-selective column-switching RP-HPLC with a titania precolumn.

A methodology of phosphopeptide-selective analysis coupled with column-switching HPLC utilizing titania as precolumn media is presented. Phosphopeptides were selectively enriched on titania packing within a protein/peptide mixture without any additional procedure, and analyzed by column-switching high-performance liquid chromatography. First, phospho-compounds were separated from complex mixtures by trapping them under acidic conditions on a titania packing, where non-phosphorylated compounds were effused out of the precolumn. Subsequently, phospho-compounds were desorbed from the titania column under a specific condition and analyzed. The behavior of phospho-compounds on a titania surface, especially adsorption/desorption, was precisely examined and optimized. A phosphoric buffer was successively employed for the elution of phosphopeptides on a titania surface by competition with the free phosphate group. From the successes of a selective concentration/analysis of phosphopeptides with column-switching HPLC with a titania precolumn, a novel phosphopeptide-selective RP-HPLC analysis has been shown to have an application possibility as a tool for phosphoproteomics.

Chromatography, High Pressure Liquid↗

Polydimethylsiloxane connection for quartz microchips in a high-pressure system.

An interconnecting technique, the "PDMS connection method", for quartz microchips in a high-pressure system is presented. The connection between quartz microchips is an essential technology for modular microfluidic devices, such as microchip-HPLC. PDMS was applied to the seal material, being spread on the seal side of the chips, and set into the metal housing. The characteristics of the PDMS connection method concerning pressure resistance and the extension of the peak were examined. The experimental results showed a good seal at 5 MPa, which seem to be sufficient for realizing microchip-HPLC utilizing a monolithic silica capillary column as a separation medium. The influence of the extra column effect on chromatographic separation was almost the same as in the case using a commercial union fitting. In addition, the PDMS connection enabled the detachability of chip-based modules with user-friendliness. Our experimental findings suggest that the novel PDMS connection method can possibly be applied as a generic technology in high-pressure microTAS.

Journal Article↗

Monolithic silica column for in-tube solid-phase microextraction coupled to high-performance liquid chromatography.

In-tube solid-phase microextraction (SPME) has successfully been coupled to capillary LC, and further an automated in-tube SPME system has been developed using a commercially available HPLC auto-sampler. However, an open tubular capillary column with a thick film of polymer (stationary phase) is unfavorable because the ratio of the surface area of coating layer contacted with sample solution to the volume of the capillary column is insufficient for mass transfer. A highly efficient SPME column is. therefore, required. We introduced a C18-bonded monolithic capillary column that was used for in-tube SPME. The column consisted of continuous porous silica having a double-pore structure. Both the through-pore and the meso-pore were optimized for in-tube SPME, and the optimized capillary column was connected to an HPLC injection valve for characterization. The results demonstrated that the pre-concentration efficiency is excellent compared with the conventional in-tube SPME. The novel method for both introduction and concentration of the samples was effective. satisfactory and suitable for use in the SPME medium.

Chromatography, High Pressure Liquid↗