PubMed Health⌕ Search

Biomedical subjects

Masahiro Toba

Publications and source records attributed to Masahiro Toba.

13 recordsLinked to original sources

Clinical applications of ECG-gated myocardial perfusion SPECT.

Erectrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) can be used to assess myocardial perfusion and left ventricular function simultaneously. Various clinical applications of gated SPECT and their usefulness have been reported. The functional variables that can be determined with gated SPECT have been limited to systolic indices. Therefore, we evaluated left ventricular diastolic function with gated SPECT using data obtained from various frames per cardiac cycle and found that date generated from 32-frames are suitable for clinical use. Serial assessment of left ventricular function was also performed during bicycle exercise and dobutamine stress by means of gated SPECT using short-time data collection. These techniques, therefore, have the potential to provide useful information for evaluating myocardial conditions, such as hibernation and residual ischemia in infarct areas. Recently, we have developed a new technique for three-dimensional registration of CT coronary angiography (CTCA) and ECG-gated myocardial perfusion SPECT. This technique of registration may assist the integration of information from gated SPECT and CTCA and may have clinical application for the diagnosis of ischemic heart disease. These various applications would contribute to the development of nuclear cardiology.

Coronary Angiography↗

Evaluation of no-reflow phenomenon using 201TlCl/123I-BMIPP dual-isotope myocardial SPECT.

OBJECTIVES: We assessed the usefulness of (201)thallous chloride (TlCl)/(123)I-beta-methyl iodophenyl pentadecanoic acid (BMIPP) dual-isotope single-photon emission computed tomography (SPECT) to identify the "no-reflow phenomenon," defined as inadequate myocardial perfusion through a given segment of the coronary circulation without angiographic evidence of mechanical vessel obstruction. METHODS: (201)TlCl/(123)I-BMIPP SPECT was performed in 73 patients within approximately 1 week of initial acute myocardial infarction (AMI) after percutaneous coronary intervention (PCI). We divided the left ventricular myocardium into 17 segments on each SPECT image and scored tracer accumulation in each segment with a five-point scoring system according to the American Heart Association criteria. Total severity scores were calculated by summing the scores for all 17 segments. The mismatch ratio between myocardial perfusion and metabolism was derived from the (201)TlCl and (123)I-BMIPP total severity scores: mismatch ratio=((123)I-BMIPP total severity score -(201)TlCl total severity score)/(123)I-BMIPP total severity score. Patients were classified according to Thrombolysis in Myocardial Infarction (TIMI) flow grade as having TIMI reflow grade 0-I (TIMI 0-I reflow group; n=11), II (TIMI II reflow group; n=17) and III (TIMI III reflow group; n=45). The TIMI III reflow group was subdivided into two groups with (201)TlCl total severity scores of < or =13 (TIMI III (A) reflow group; n=36) and > or =14 (TIMI III (B) reflow group; n=9), respectively. RESULTS: The mismatch ratios in the TIMI II (0.4 +/- 0.3) and TIMI III (0.4 +/- 0.2) reflow groups were significantly higher than that in the TIMI 0-1 reflow group (0.1 +/- 0.1, p<0.05). Although coronary angiography revealed TIMI III flow after reperfusion, the mismatch ratios in the TIMI III (B) reflow group (0.2 +/- 0.1) and in the TIMI 0-I reflow group (0.1 +/- 0.1) were significantly lower than that in the TIMI III (A) reflow group (0.4 +/- 0.2, p<0.01), reflecting noneffective recanalization (so called no-reflow phenomenon). CONCLUSION: (201)TlCl/(123)I-BMIPP dual-isotope myocardial SPECT reveals the biochemical degree of the no-reflow phenomenon, whereas coronary angiography shows recanalized vascular flow only. Dual-isotope myocardial SPECT might be useful for evaluating reperfusion therapy.

Adult↗

Assessment of contractile response to dobutamine stress by means of ECG-gated myocardial SPECT: comparison with myocardial perfusion and fatty acid metabolism.

UNLABELLED: The present study assessed left ventricular performance during dobutamine stress measured using gated SPECT, and compared the results to myocardial perfusion and fatty acid metabolism. METHODS: Thirty-six patients with myocardial infarction given (99m)Tc-sestamibi or (99m)Tc-tetrofosmin were examined by gated SPECT at rest and during dobutamine stress (4-20 microg x kg(-1) x min(-1)). After acquiring data at the highest dose, 201TlCl was injected and dual-isotope SPECT was performed to assess myocardial ischemia. Thirty of 36 patients also underwent myocardial SPECT with 123I-BMIPP. Regional wall motion changes during dobutamine infusion were determined from the gated SPECT data and classified as: (1) Improvement, (2) Worsening, (3) No change, and (4) Biphasic response. For myocardial segments of each infarct area, stress 201Tl, rest (99m)Tc and (123)I-BMIPP uptakes were graded on a five-point scoring system of defects from 0 (normal) to 4 (grossly defective). RESULTS: Rest 99mTc defect score index (DSI) in No change area was significantly higher than that in Biphasic area. The ADSI (stress 201Tl - rest (99m)Tc) in Biphasic area was significantly higher than those in Improvement and No change areas. The deltaDSI (BMIPP - (99m)Tc) in Worsening area tended to be higher than that in No Change area. CONCLUSIONS: Regional contractile response to dobutamine stress analyzed by gated SPECT showed that the response in-myocardial infarct areas could be classified by rest and stress myocardial perfusion and BMIPP accumulation.

Coronary Vessels↗

Three-dimensional display in staging hemodynamic brain ischemia for JET study: objective evaluation using SEE analysis and 3D-SSP display.

The Japanese EC-IC bypass trial (JET study) was established to evaluate the validity of MCA-STA anastomosis in intracranial arterial occlusive disease aiming at stroke prevention. This study must use an objective method to reliably estimate hemodynamic brain ischemia. We devised a method of objectively classifying the severity of hemodynamic ischemia using quantitatively analytical and display software, stereotactic extraction estimation for stereotactic brain coordinates and three-dimensional stereotactic surface projections (3D-SSP). We analyzed data from 16 patients registered in the JET study. Our method offers quantitative information and 3-dimensional displays of the CBF at rest and after Diamox challenge, vascular reserve and the severity of the hemodynamic brain ischemia. We compared the maximal projection counts with ROI data from tomographic images in the anterior commissure-posterior commissure plane. The maximal counts data correlated closely with the ROI data of rest and with Diamox SPECT images (both p < 0.0001). The slopes of the linear regression line were 1.15 and 1.12, respectively. The results of this study indicated that our method could simply and objectively evaluate the severity of impaired brain circulation. This procedure should support the evaluation of hemodynamic ischemia in the JET study although validation is required by several institutions using more study subjects.

Aged↗

[Practice and future aspects of nuclear cardiology].

The field of nuclear cardiology has demonstrated sustained growth in recent years owing to its increasingly recognized value for clinical applications and patient management. Computer advances in this field have allowed the technology of ECG-gated SPECT to become a routine part of nuclear cardiology. In our laboratory, myocardial perfusion and left ventricular function during stress (bicycle exercise or dobutamine infusion) were analyzed in a single examination by means of gated SPECT. This procedure has the potential to provide comprehensive information with which to evaluate patients with ischemic heart disease. 123I-BMIPP is a branched-chain free fatty acid, and its distribution could provide useful information about metabolic function in patients with ischemic heart disease (including minor infarction). The solid-state gamma camera 2020 tc Imager is now commercially available and has been clinically applied. The lightweight and compact design of the camera allows mobility of the unit between departments and floors. This technique would be useful for assessing left ventricular function under emergency conditions. In this paper, the techniques of examinations are described, and potential assessments are addressed. We look forward to further advances in nuclear cardiology for the accurate diagnosis and management of patients with various cardiac diseases.

Electrocardiography↗

Development of quantitative analysis method for stereotactic brain image: assessment of reduced accumulation in extent and severity using anatomical segmentation.

Through visual assessment by three-dimensional (3D) brain image analysis methods using stereotactic brain coordinates system, such as three-dimensional stereotactic surface projections and statistical parametric mapping, it is difficult to quantitatively assess anatomical information and the range of extent of an abnormal region. In this study, we devised a method to quantitatively assess local abnormal findings by segmenting a brain map according to anatomical structure. Through quantitative local abnormality assessment using this method, we studied the characteristics of distribution of reduced blood flow in cases with dementia of the Alzheimer type (DAT). Using twenty-five cases with DAT (mean age, 68.9 years old), all of whom were diagnosed as probable Alzheimer's disease based on NINCDS-ADRDA, we collected I-123 iodoamphetamine SPECT data. A 3D brain map using the 3D-SSP program was compared with the data of 20 cases in the control group, who age-matched the subject cases. To study local abnormalities on the 3D images, we divided the whole brain into 24 segments based on anatomical classification. We assessed the extent of an abnormal region in each segment (rate of the coordinates with a Z-value that exceeds the threshold value, in all coordinates within a segment), and severity (average Z-value of the coordinates with a Z-value that exceeds the threshold value). This method clarified orientation and expansion of reduced accumulation, through classifying stereotactic brain coordinates according to the anatomical structure. This method was considered useful for quantitatively grasping distribution abnormalities in the brain and changes in abnormality distribution.

Aged↗

Assessment of left ventricular function using solid-state gamma camera equipped with a highly-sensitive collimator.

PURPOSE: The solid-state gamma camera 2020tc Imager (Digirad, CA) is now commercially available and has been clinically applied. The present study evaluates the feasibility of equilibrium radionuclide ventriculography (ERNV) within a 3 min period using this camera equipped with a highly sensitive collimator. MATERIALS AND METHODS: ERNV was performed from the best septal position (left anterior oblique view) in 20 patients with cardiac disease using a single detector anger-type gamma camera equipped with a low-energy, high-resolution collimator. Immediately thereafter, we performed a second ERNV using the solid-state gamma camera equipped with a highly sensitive collimator. Acquisition periods were 10 and 3 min, respectively. RESULTS: Significantly more counts were collected from over the left ventricle with the solid-state gamma camera over 3 min than those with the anger-type gamma camera over 10 min (817.1 +/- 387.8 k counts vs. 668.2 +/- 327.4 k counts, p < 0.01). The left ventricular ejection fraction obtained from ERNV data using the solid-state gamma camera correlated closely with those acquired by the anger-type gamma camera (r = 0.94, p < 0.0001, SEE = 5.93%). CONCLUSION: The results showed that the solid-state gamma camera could assess left ventricular function with excellent data collection efficiency and high reliability.

Equipment Failure Analysis↗

Serial assessment of left ventricular performance at rest and during bicycle exercise by ECG-gated myocardial perfusion SPECT.

UNLABELLED: The present study evaluates left ventricular performance during exercise by ECG-gated myocardial perfusion SPECT with short-time data collection. METHODS: The study population consisted of 10 healthy volunteers (Group N) and 9 patients with ischemic heart disease (Group I). Seven patients in Group I had a history of prior myocardial infarction. Rest ECG-gated SPECT was performed 40 min after an injection of Tc-99m-tetrofosmin (555-740 MBq). After resting data acquisition, Group N underwent up to two 5-min stages of exercise (75 and 125 watts) on a detachable bicycle ergometer. The Group I patients all underwent symptom-limited, maximal testing on the ergometer. ECG-gated SPECT data were acquired from both groups for 3 min at rest and during the last 3 min of each exercise stage. RESULTS: Significant increases occurred in LVEF from rest to peak stress in both groups (from 55.4 +/- 5.8 to 66.6 +/- 4.1% in group N, p < 0.0001; from 49.0 +/- 12.8 to 56.7 +/- 13.8% in Group I, p < 0.001). The LVESV values significantly decreased to peak stress in Group N (from 49.9 +/- 13.1 to 37.8 +/- 10.0 ml, p < 0.0001), whereas LVEDV did not change (from 110.6 +/- 18.9 to 112.0 +/- 19.0 ml). In contrast, the LVESV values at rest and under peak stress were similar in Group I (from 52.6 +/- 23.9 to 51.7 +/- 31.4 ml) and LVEDV in Group I at peak exercise tended to increase (from 102.8 +/- 36.7 to 111.3 +/- 39.0 ml). The changes in LVESV from rest to peak stress were significantly different between Groups N and I (-12.1 +/- 6.3 vs. -0.9 +/- 11.6 ml, p < 0.02). CONCLUSION: ECG-gated SPECT with short-time data collection can assess left ventricular function during exercise and may offer useful information for evaluating patients with ischemic heart disease.

Adult↗

Assessment of myocardial washout of Tc-99m-sestamibi in patients with chronic heart failure: comparison with normal control.

BACKGROUND: In contrast to 201TlCl, 99mTc-sestamibi shows very slow myocardial clearance after its initial myocardial uptake. In the present study, myocardial washout of 99mTc-sestamibi was calculated in patients with non-ischemic chronic heart failure (CHF) and compared with biventricular parameters obtained from first-pass and ECG-gated myocardial perfusion SPECT data. METHODS AND RESULTS: After administration of 99mTc-sestamibi, 25 patients with CHF and 8 normal controls (NC) were examined by ECG-gated myocardial perfusion SPECT and planar data acquisition in the early and delayed (interval of 3 hours) phase. Left ventricular ejection fraction (LVEF, %), peak filling rate (PFR, sec(-1)), end-diastolic volume (LVEDV, ml) and end-systolic volume (LVESV, ml) were automatically calculated from the ECG-gated SPECT data. Myocardial washout rates over 3 hours were calculated from the early and delayed planar images. Myocardial washout rates in the CHF group (39.6+/-5.2%) were significantly higher than those in the NC group (31.2+/-5.5%, p < 0.01). The myocardial washout rates for the 33 subjects showed significant correlations with LVEF (r = -0.61, p < 0.001), PFR (r = -0.47, p < 0.01), LVEDV (r = 0.45, p < 0.01) and LVESV (r = 0.48, p < 0.01). CONCLUSION: The myocardial washout rate of 99Tc-sestamibi is considered to be a novel marker for the diagnosis of myocardial damage in patients with chronic heart failure.

Adult↗

[Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography].

UNLABELLED: Quantitative blood pool SPECT (QBS) is a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (TMUGA). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. MATERIALS AND METHODS: Thirty-five patients with cardiac disease were enrolled. Following intravenous bolus injection of 740 MBq of 99mTc human serum albumin-DTPA, first-pass radionuclide angiography (FP) and 25-gated interval planar multi-gated blood pool scintigraphy (PMUGA) were performed for the measurement of right ventricular ejection fraction (RVEF; %) and left ventricular ejection fraction (LVEF; %), respectively. Subsequently TMUGA data set was acquired with a dual-head gamma camera (16 gated intervals). Then, alternative LVEF and RVEF were measured using TMUGA with QBS. Regional left ventricular wall motion for both PMUGA and TMUGA were assessed with a 4-point scoring system respectively. RESULTS: Automatic biventricular border detection using QBS was feasible in 27 of 35 patients (70.7%). Measurements of TMUGA LVEF and RVEF were well reproducible, with interobserver correlation coefficient of 0.98 and 0.97, respectively. TMUGA LVEF showed excellent correlation with PMUGA LVEF (r = 0.98, SEE = 3.92%). The agreement of LV wall motion score between TMUGA and PMUGA was 88.1% (214 of 243 segments), with a kappa value of 0.82. On the other hand, RVEF determined by QBS had a 12.4% average overestimate compared to the same value obtained by FP. Moreover 95% confidential interval of TMUGA RVEF (-28.8 to +4.0%) was wider than that of TMUGA LVEF (-10.7 to +10.7%). CONCLUSION: TMUGA with QBS analysis provided accurate and reproducible data for global and regional left ventricular function. However, the results of RVEF with TMUGA were not satisfying as a replacement for those with FP and modifying the algorithm were needed to improve accuracy of quantification.

Adult↗

[Cardiac pool scintigraphy using the solid-state Digirad 2020tc Imager--comparison with the conventional anger-type gamma camera using moving cardiac phantom].

UNLABELLED: Movable gamma camera, 2020tc Imager, was light miniaturized using Si photodiode as a semiconductor sensor instead of photomultiplier tubes. To validate performance of this new camera in cardiac pool scintigraphy, multigated equilibrium radionuclide ventriculography using the moving cardiac phantom was performed with 2020tc Imager and a conventional Agner-type gamma camera (PRISM 3000). METHOD: Both measured cardiac functional values were compared with the set-up ones for the phantom. Five-, 7.5-, and 10-minute-multigated data were acquired using both cameras under constant contractile condition. Constant 5-minute-multigated data acquisitions using 2020tc Imager were also carried out with varied contractile conditions. RESULTS: Measured ejection fraction (EF) derived from 2020tc Imager and an Anger-type camera were 68.5 +/- 0.6 and 70.3 +/- 1.4%, respectively. Both of these values were absolutely close to the set-up EF value of 70%. Both of end-diastolic volume and EF showed excellent correlation between set-up and measured values with the correlation coefficient of 0.97 and 0.99, respectively. CONCLUSION: This new movable camera could provide comparative cardiac functional values with an Anger-type camera and it can be useful to evaluate acute cardiac function in a coronary care unit.

Gamma Cameras↗

Usefulness of gated myocardial perfusion SPECT imaging soon after exercise to identify postexercise stunning in patients with single-vessel coronary artery disease.

BACKGROUND: This study determines the value of gated single photon emission computed tomography (SPECT) imaging soon after exercise to identify patients with single-vessel disease and exercise-induced prolonged myocardial dysfunction (ie, postischemic stunning). METHODS AND RESULTS: We examined 19 normal individuals and 52 patients with single-vessel disease by use of 2-day technetium 99m tetrofosmin exercise/rest gated SPECT imaging. Sequential imaging was started 10, 30, and 50 minutes after exercise. The ejection fraction (EF) values were calculated with the Cedars-Sinai program. The participants were classified as follows: group A (normal individuals, n = 19), group B (individuals with coronary stenosis without Q-wave infarction, n = 18), group C (individuals with Q-wave infarction without myocardial ischemia, n = 15), and group D (individuals with Q-wave infarction and ischemia, n = 19). The post-stress EF values at 10 minutes (69.8% +/- 9.6% and 59.8% +/- 11.8%, respectively) were higher in groups A and C than those at 30 minutes (67.6% +/- 10.2% and 57.2% +/- 11.3%, respectively) ( P < .05) but were lower in group B (61.7% +/- 9.2%) than both the 30- and 50-minute values (64.2% +/- 9.5% and 64.6% +/- 9.4%, respectively; P < .05). The EF value did not significantly change in group D. CONCLUSIONS: Tc-99m gated SPECT imaging soon after exercise is superior to conventional late imaging to discriminate patients with single-vessel disease and postexercise stunning.

Adult↗

Prognostic value of I-123 15-(p-iodophenyl)-3-(R,S) methylpentadecanoic acid myocardial imaging in patients with known or suspected coronary artery disease.

BACKGROUND: Although iodine 123 15-(p-iodophenyl)-3-(R , S) methylpentadecanoic acid (BMIPP) can assess abnormal utilization of fatty acid in the diseased myocardium, the prognostic value of BMIPP imaging at rest in patients with known or suspected coronary artery disease (CAD) remains unclear. METHODS AND RESULTS: A total of 270 patients were included by a retrospective search of the existing databases of 4 institutions. In addition to hard events, consisting of cardiac death and nonfatal myocardial infarction, any significant events including death, nonfatal myocardial infarction, coronary revascularization, heart failure, and unstable angina were assessed. During a median follow-up of 3.9 years, 33 patients had significant events, among whom 10 had hard events. Kaplan-Meier survival estimates revealed a hard event-free survival rate of 98% at 3 years in patients with a BMIPP defect score lower than 5 but 93% in those with a defect score of 5 or greater ( P = .03). With regard to significant events, the analysis showed an event-free survival rate of 92% at 3 years in patients with a BMIPP defect score lower than 5 but 80% in those with a defect score of 5 or greater ( P = .0003). CONCLUSIONS: These results indicate that resting BMIPP imaging has prognostic value and may have a role in the risk stratification of patients with known or suspected CAD.

Adult↗