PubMed Health⌕ Search

Biomedical subjects

Masaki Takashina

Publications and source records attributed to Masaki Takashina.

9 recordsLinked to original sources

Suctioning prevents emboli during insertion of acetabular components without holes.

Embolic events can occur when inserting uncemented press-fit acetabular components (cups), especially those without holes. However, there is a paucity of literature regarding prevention of embolic events. We asked whether suctioning in the acetabulum might be as effective as suctioning during femoral insertion. We compared embolic events in 30 hips (27 patients) (Group 1) that had conventional press-fit cup fixation without holes, with 30 hips (27 patients) (Group 2) treated by suctioning from a cannula in the ilium during cup impaction. We evaluated embolic events using transesophageal echocardiography, blood gas (PaO2, PaCO2), and blood pressure preoperatively and 5 minutes after cup placement. Echocardiography showed less severe embolic events in Group 2 (23%) than in Group 1 (100%). The decrease in rate of the PaO2 and the blood pressure from baseline to 5 minutes after cup placement were lower in Group 2 than in Group 1. Our data suggest the suctioning technique is effective to reduce embolic events by cup without holes which may cause intraoperative embolic complications.

Acetabulum↗

Electroencephalographic bicoherence is sensitive to noxious stimuli during isoflurane or sevoflurane anesthesia.

BACKGROUND: The authors previously reported changes in electroencephalographic bicoherence during isoflurane anesthesia combined with epidural anesthesia. Here, they examined the influence of noxious stimuli on electroencephalographic bicoherence as well as on the Bispectral Index (BIS) and the 95% spectral edge frequency (SEF95). METHODS: The authors enrolled 48 elective abdominal surgery patients (aged 22-77 years; American Society of Anesthesiologists physical status I or II). Raw electroencephalographic signals as well as BIS and SEF95 were recorded on a computer using a BIS monitor (A-1050) and Bispectrum Analyzer (BSA) for BIS (the authors' original software). Using BSA for BIS, the authors evaluated the two peak heights of electroencephalographic bicoherence. Anesthesia was induced with 3 mg/kg thiopental and was maintained with, in air-oxygen, 1.0% isoflurane or 1.5% sevoflurane. After confirming the steady state, the authors recorded baseline values. In experiment 1, they administered 3 microg/kg fentanyl 5 min after incision and investigated the changes in electroencephalographic derivatives at 5 and 10 min after incision. In experiment 2, they administered a similar dose of fentanyl 5 min before incision and investigated the changes in electroencephalographic derivatives immediately before and 5 min after incision. RESULTS: In experiment 1, after incision, both peak heights of electroencephalographic bicoherence significantly decreased but returned to control values after fentanyl administration. By contrast, after incision, BIS and SEF95 showed individual variability. In experiment 2, although fentanyl itself did not affect all electroencephalographic derivatives before incision, the variables remained unchanged after incision. CONCLUSION: Noxious stimuli decreased the peak heights of electroencephalographic bicoherence, an effect that was counteracted by fentanyl analgesia.

Adult↗

Embolic events during total hip arthroplasty: an echocardiographic study.

We performed transesophageal echocardiography on 88 patients treated with cementless or hybrid total hip arthroplasty (THA). We observed a significantly higher frequency of severe embolic events among patients without cup holes during insertion of press-fit cups (46.0%) than in patients with holes (15.6%) (P<.005). During stem insertion, severe embolic events occurred in 61.5% of hybrid operations and 5.9% of cementless operations. PaO(2), systolic blood pressure, and arterial oxygen saturation decreased significantly in severe embolic events (P<.05). The results indicate that embolic events may occur during THA whether or not cement is used. Based on these findings, we make several recommendations for technique modifications during insertion of both femoral and acetabular components in THA.

Adult↗

Effectiveness of the ROBODOC system in preventing intraoperative pulmonary embolism.

Intraoperative pulmonary embolism occurs not only during cemented but also during cementless total hip arthroplasty (THA). We determined whether the ROBODOC femoral milling system can reduce intraoperative pulmonary embolism, by using of transesophageal echocardiography and hemodynamic monitoring. We did a prospective clinical trial with 71 patients (75 hips) who were divided into 2 groups: group 1, 46 patients (50 hips) who underwent cementless THA with preparation of the femoral canal using ROBODOC; group 2, 25 patients (25 hips) who underwent conventional cementless THA surgery in whom separate measurements were made during preparation of the femur, insertion of the stem and relocation of the hip. The incidence of severe embolic events was lower in group 1 than in group 2. Our findings suggest that the ROBODOC femoral milling system may reduce the risk of clinically significant pulmonary embolism during cementless THA.

Aged↗

[Occupational exposure of operating room staff to anesthetic gases during inhaled induction--a comparison with intravenous anesthesia induction].

BACKGROUND: The risk of occupational exposure to waste anesthetic gases still remains during inhaled induction. In this study we investigated how much we were occupationally exposed to anesthetic gases during induction period. METHODS: Twenty-six adult patients were induced with sevoflurane 5% using a face mask for three minutes and maintained with sevoflurane 1% after end-tracheal intubations (IH-Group). Twenty-two adult patients were induced with intravenous anesthetics and maintained with sevoflurane 1% after end-tracheal intubations(IV-Group). The concentration of sevoflurane was measured by Multi-gas Monitor 1302 (Bruel & Kjaer: Denmark) every 70 seconds. Sample gas was suctioned from breathing zone of anesthesiologists. All of our operating rooms are equipped with waste gas scavenging system. RESULTS: The peak concentration of sevoflurane is significantly higher in IH-Group (15.91 +/- 22.64 ppm) compared with IV-group (0.36 +/- 0.25 ppm). The period when sevoflurane concentration exceeded 0.5 ppm is significantly longer IH-Group (18.55 +/- 10.51 min.) compared to IV-Group (1.92 +/- 4.56 min.). CONCLUSION: The induction with intravenous anesthetics is a better method in order to reduce occupational exposure of anesthesiologists to anesthetic gases.

Adult↗

Changes of electroencephalographic bicoherence during isoflurane anesthesia combined with epidural anesthesia.

BACKGROUND: The authors previously reported that, during isoflurane anesthesia, electroencephalographic bicoherence values changed in a fairly restricted region of frequency versus frequency space. The aim of the current study was to clarify the relation between electroencephalographic bicoherence and the isoflurane concentration. METHODS: Thirty elective abdominal surgery patients (male and female, aged 34-77 yr, American Society of Anesthesiologists physical status I-II) were enrolled. After electroencephalogram recording with patients in an awake state, anesthesia was induced with 3 mg/kg thiopental and maintained with oxygen and isoflurane. Continuous epidural anesthesia with 80-100 mg/kg 1% lidocaine was also administered. Using software they developed, the authors continuously recorded the FP1-A1 lead of the electroencephalographic signal and expired isoflurane concentration to an IBM-PC compatible computer. After confirming the steady state of each isoflurane (end-tidal concentration at 0.3, 0.5, 0.7, 0.9, 1.1, 1.3, and 1.5%), electroencephalographic bicoherence values were calculated. RESULTS: In a light anesthetic state, electroencephalographic bicoherence values were low (generally < or = 15.0%). At increased concentrations of isoflurane, two peaks of electroencephalographic bicoherence emerged along the diagonal line (f1=f2). The peak emerged at around 4.0 Hz and grew higher as isoflurane concentration increased until it reached a plateau (43.8 +/- 3.5%, mean +/- SD) at isoflurane 0.9%. The other peak, at about 10.0 Hz, also became significantly higher and reached a plateau (32.6 +/- 9.2%) at isoflurane 0.9%; at isoflurane 1.3%, however, this peak slightly decreased. CONCLUSION: Changes in the height of two electroencephalographic bicoherence peaks correlated well with isoflurane concentration.

Adult↗