PubMed Health⌕ Search

Biomedical subjects

Masako Nagayama

Publications and source records attributed to Masako Nagayama.

5 recordsLinked to original sources

Quantification of left ventricular volumes from cardiac cine MRI using active contour model combined with gradient vector flow.

We investigated the feasibility of combining the active contour model with gradient vector flow (Snakes-GVF) to estimate left ventricular (LV) volumes from cardiac cine magnetic resonance imaging (MRI). MRI data were acquired from 27 patients, including 14 adults (9 men, 5 women, 55.0+/-23.3 years) and 13 children (10 boys, 3 girls, 2.7+/-2.1 years) using Gyroscan Intera (1.5 Tesla, Philips Medical Systems). LV volumes were calculated by adding the areas surrounded by the contour extracted by Snakes-GVF and compared with volumes estimated by manual tracing. Those estimated by Snakes-GVF [y (mL)] correlated well with those estimated by manual tracing [x (mL)]. In adult cases, the regression equation and correlation coefficient were y=1.008x - 0.517 and 0.996, respectively. In pediatric cases, they were y=1.174x - 2.542 and 0.992, respectively. In conclusion, Snakes-GVF is a powerful and useful tool for quantifying LV volumes using cardiac MRI.

Cardiac Volume↗

Automatic motion correction for quantification of myocardial perfusion with dynamic magnetic resonance imaging.

Respiratory motion makes it difficult to quantify myocardial perfusion with dynamic magnetic resonance imaging (MRI). The purpose of this study was to evaluate an automatic registration method for motion correction for quantification of myocardial perfusion with dynamic MRI. The present method was based on the gradient-based method with robust estimation of displacement parameters. For comparison, we also corrected for motion with manual registration as the benchmark. The myocardial kinetic parameters, K1 (rate constant for transfer of contrast agent from blood to myocardium) and k2 (rate constant for transfer from myocardium to blood), were calculated from dynamic images with a two-compartment model. The images corrected by the present method were similar to those corrected by manual registration. The kinetic parameters obtained after motion correction with the present method were close to those obtained after motion correction with manual registration. These results suggest that the present method is useful for motion correction for quantification of myocardial perfusion with dynamic MRI.

Contrast Media↗

High-resolution selective three-dimensional magnetic resonance coronary angiography with navigator-echo technique: segment-by-segment evaluation of coronary artery stenosis.

PURPOSE: To investigate the feasibility of high-resolution selective three-dimensional (3D) magnetic resonance coronary angiography (MRCA) in the evaluation of coronary artery stenoses. MATERIALS AND METHODS: In 12 patients with coronary artery stenoses, MRCA of the coronary artery groups, including the coronary segments with stenoses of 50% or greater based on conventional x-ray coronary angiography (CAG), was performed with double-oblique imaging planes by orienting the 3D slab along the major axis of each right coronary artery-left circumflex artery (RCA-LCX) group and each left main trunk-left anterior descending artery (LMT-LAD) group. Ten RCA-LCX and five LMT-LAD MR angiograms were obtained, and the results were compared with those of conventional x-ray angiography. RESULTS: Among 70 coronary artery segments expected to be covered, a total of 49 (70%) segments were fully demonstrated in diagnostic quality. The identification of segmental location of stenoses showed as high an accuracy as 96%. The retrospective analysis for stenosis of 50% or greater yielded the sensitivity, specificity, and accuracy of 80%, 85%, and 84%, respectively. CONCLUSION: Selective 3D MRCA has the potential for segment-by-segment evaluation of major portions of the right and left coronary arteries with high accuracy.

Aged↗

Fast MR imaging in obstetrics.

Ultrasonography (US) is the initial imaging modality of choice for evaluation of patients in obstetrics. However, the results of US are not always sufficient. Magnetic resonance (MR) imaging, which uses no ionizing radiation, may be an ideal method for further evaluation. Although MR imaging is not recommended during the first trimester and use of contrast material is not recommended in pregnant patients, fast MR imaging is useful in various obstetric settings and can provide more specific information with excellent tissue contrast and multiplanar views. In pregnant patients with acute conditions, various diseases (eg, red degeneration of a uterine leiomyoma) may be diagnosed. MR imaging allows characterization of pelvic masses discovered during pregnancy and diagnosis of postpartum complications (eg, abscess, hematoma, ovarian vein thrombosis). In pregnant patients with hydronephrosis, MR urography can demonstrate the site of obstruction and the cause (eg, a ureteral stone). MR pelvimetry may be beneficial in cases of breech presentation. Contrast material-enhanced dynamic MR imaging allows one to evaluate the vascularity of a placental polyp, detect the viable component of a gestational trophoblastic tumor, and diagnose a uterine arteriovenous malformation. MR imaging enables diagnosis of rare forms of ectopic pregnancy and early diagnosis of ectopic pregnancy.

Adult↗