PubMed Health⌕ Search

Biomedical subjects

Masami Ando

Publications and source records attributed to Masami Ando.

5 recordsLinked to original sources

Hard-x-ray region tomographic reconstruction of the refractive-index gradient vector field: imaging principles and comparisons with diffraction-enhanced-imaging-based computed tomography.

The unique tomographic imaging method based on refractive effects that was recently developed by Maksimenko et al. [Appl. Phys. Lett. 86, 124105 (2005)] exhibits an excellent imaging property in the hard-x-ray region for phase objects such as soft materials and biological samples. However, there seems to have been little consideration of the physical aspects of the underlying imaging principles. Also, as the method is similar to diffraction-enhanced-imaging (DEI)-based computed tomography (CT), the difference between these two methodologies has not been made clear. We theoretically consider the imaging principles starting from the measurement process to the reconstruction procedures from the viewpoint of geometrical optics and then clarify their difference in relationship to the physical quantities to be depicted. The major feature of this novel method is the in-plane two-dimensional vector-field reconstruction of the refractive-index gradient in an object, while DEI CT obtains the out-of-plane scalar-field gradient component. In other words, the novel method and DEI CT present the transverse and the longitudinal components, respectively, of the three-dimensional vector fields of the gradient refractive index. Therefore they can be considered complementary to each other.

Algorithms↗

Articular cartilage depicted at optimized angular position of Laue angular analyzer by X-ray dark-field imaging.

Using 36.0 keV X-ray from synchrotron radiation, we examined the optimized angular position of Laue analyzer for depicting articular cartilage of an intact human finger by X-ray dark-field imaging. The surface of articular cartilage was depicted clearly by adopting the offset angle of 0.04 arcsec to lower angular side to the analyzer whilst the contour of articular cartilage was delineated clearly at the other angular positions of the analyzer within the width of the rocking curve.

Anisotropy↗

First application of X-ray refraction-based computed tomography to a biomedical object.

We have developed X-ray refraction-based computed tomography (CT) that is able to visualize soft tissue in between hard tissue. The experimental system consists of Si(220) diffraction double-crystals and is called the DEI (diffraction-enhanced imaging) method, in which the object is located between the crystals and a CCD camera to acquire data as 360 X-ray images. The X-ray energy used was 17.5 keV. The algorithm used to reconstruct CT images was developed by A. Maksimenko and colleagues. We successfully visualized articular cartilage and the distribution of bone marrow, which are inner structures. Our method has much higher contrast compared to the conventional absorption-based CT system.

Algorithms↗

High-pass-filtered diffraction microtomography by coherent hard x rays for cell imaging: theoretical and numerical studies of the imaging and reconstruction principles.

This paper presents theoretical and numerical studies of diffraction tomography using hard x rays, from the viewpoint of imaging and reconstruction methods for cell imaging. The proposed system employs a single-perfect-crystal analyzer in symmetric Laue-case transmission geometry to efficiently detect the higher spatial frequency components of an object's refractive-index distribution, and to effectively suppress interference between the unperturbated wave field and the wave field diffracted by the object. This system features acquisition of a single projection by a single exposure using a simple geometry and aggressive use of diffracted x rays. We present the physical description of the imaging method using the Fourier diffraction theorem derived from the Born approximation. First, we demonstrate that the reconstruction leads to the phase-retrieval problem. We then describe a reconstruction algorithm based on the classical Gerchberg-Saxton-Fienup algorithm. Finally, we show the efficacy of this system by computer simulation. Our simulation demonstrates that the imaging system delineates microstructure 3.5 microm in diameter in a phase object 400 microm in diameter.

Algorithms↗

Measurement of the two-photon correlation of synchrotron radiation in the VUV region by a delay-time modulation technique.

The two-photon correlation (second-order coherence) of synchrotron radiation in the VUV region (hnu = 55 eV) has been measured using a novel photon-counting method. A new technique has been developed to measure a small bunching effect by using a coincidence unit composed of a constant fraction discriminator, a time-to-amplitude converter (TAC), a single-channel analyzer (SCA) and two solid-state switches. The path of the circuit through which the stop signal for the TAC passes can be changed by a control voltage generated by a function generator, and the relative arrival time of two photons on condition that the output signal from the SCA appears is consequently changed. By modulating the arrival time and measuring the output rate from the SCA with a digital lock-in amplifier, an apparent bunching effect has been observed which is characteristic of the chaotic light. The electron-beam emittance in the horizontal direction was estimated as 39(-8)(+13) nm rad by this experiment, and the value was consistent with the designed value of 36 nm rad.

Journal Article↗