PubMed Health⌕ Search

Biomedical subjects

Masami Goto

Publications and source records attributed to Masami Goto.

13 recordsLinked to original sources

Effects of angiotensin II on NO bioavailability evaluated using a catheter-type NO sensor.

We investigated the acute or chronic effects of angiotensin (Ang) II on the bioavailability of NO in Ang II-infused rabbits using the catheter-type NO sensor. Male New Zealand White rabbits were infused with vehicle (sham), Ang II at a rate of 200 ng/kg per minute, either alone or in combination with hydralazine, Ang II type I receptor antagonist (valsartan), or an antioxidant (tempol) for 24 hours or 14 days. Plasma NO concentration was measured using the catheter-type NO sensor located in the aorta. We then infused saline (vehicle) and acetylcholine (ACh) into the aortic arch with or without pretreatment with N(G)-methyl-l-arginine. An increase in plasma NO levels in response to ACh was significantly attenuated in the Ang II group compared wit the control group. The decrease in the basal plasma NO concentration was significantly lower in the Ang II group than in the control group. Plasma peroxynitrite concentrations in Ang II group were significantly higher than in the control group. The negative effects of Ang II, that is, the decrease in basal and ACh-induced NO production and the increase in oxidative stress, were significantly suppressed by the cotreatment with either valsartan or tempol. Short-term treatment with Ang II significantly increased the ACh-induced increase in plasma NO concentration, as well as basal NO release. Although Ang II stimulates release of NO in the short term, chronic treatment with Ang II elicits the decreased NO bioavailability in the aorta of the Ang II-infusion rabbit model.

Angiotensin II↗

[Utility of axial images in an early Alzheimer disease diagnosis support system (VSRAD)].

In recent years, voxel-based morphometry (VBM) has become a popular tool for the early diagnosis of Alzheimer disease. The Voxel-Based Specific Regional Analysis System for Alzheimer's Disease (VSRAD), a VBM system that uses MRI, has been reported to be clinically useful. The able-bodied person database (DB) of VSRAD, which employs sagittal plane imaging, is not suitable for analysis by axial plane imaging. However, axial plane imaging is useful for avoiding motion artifacts from the eyeball. Therefore, we created an able-bodied person DB by axial plane imaging and examined its utility. We also analyzed groups of able-bodied persons and persons with dementia by axial plane imaging and reviewed the validity. After using the DB of axial plane imaging, the Z-score of the intrahippocampal region improved by 8 in 13 instances. In all brains, the Z-score improved by 13 in all instances.

Alzheimer Disease↗

[Examination of an imaging method in early Alzheimer disease diagnosis support system (VSRAD)].

The use of voxel-based morphometry (VBM) has recently become a popular tool for the early diagnosis of Alzheimer disease. The Voxel-Based Specific Regional Analysis System for Alzheimer's Disease (VSRAD) is a clinically useful VBM that employs MRI. However, there has been insufficient information about the influence of the image pickup apparatus and imaging conditions in terms of the value calculated by the sensitivity correction. We therefore reviewed this problem in a volunteer who provided consent. We were able to confirm reproducibility under the same conditions. When changing the image pickup apparatus and conditions, the average Z-score of 0.18+/-0.21 became larger, and the change in Z-score increased when imaging was done in the axial plane. Further, the average Z-score of 0.06+/-0.21 for sensitivity correction use was high on average by 0.19+/-0.16 for phased-array uniformity enhancement (PURE) and low for surface coil intensity correction (SCIC).

Adult↗

Cardioprotective role of endogenous hydrogen peroxide during ischemia-reperfusion injury in canine coronary microcirculation in vivo.

We have recently demonstrated that endogenous H2O2 plays an important role in coronary autoregulation in vivo. However, the role of H2O2 during coronary ischemia-reperfusion (I/R) injury remains to be examined. In this study, we examined whether endogenous H2O2 also plays a protective role in coronary I/R injury in dogs in vivo. Canine subepicardial small coronary arteries (>or=100 microm) and arterioles (<100 microm) were continuously observed by an intravital microscope during coronary I/R (90/60 min) under cyclooxygenase blockade (n=50). Coronary vascular responses to endothelium-dependent vasodilators (ACh) were examined before and after I/R under the following seven conditions: control, nitric oxide (NO) synthase (NOS) inhibitor NG-monomethyl-L-arginine (L-NMMA), catalase (a decomposer of H2O2), 8-sulfophenyltheophylline (8-SPT, an adenosine receptor blocker), L-NMMA+catalase, L-NMMA+tetraethylammonium (TEA, an inhibitor of large-conductance Ca2+-sensitive potassium channels), and L-NMMA+catalase+8-SPT. Coronary I/R significantly impaired the coronary vasodilatation to ACh in both sized arteries (both P<0.01); L-NMMA reduced the small arterial vasodilatation (both P<0.01), whereas it increased (P<0.05) the ACh-induced coronary arteriolar vasodilatation associated with fluorescent H2O2 production after I/R. Catalase increased the small arterial vasodilatation (P<0.01) associated with fluorescent NO production and increased endothelial NOS expression, whereas it decreased the arteriolar response after I/R (P<0.01). L-NMMA+catalase, L-NMMA+TEA, or L-NMMA+catalase+8-SPT further decreased the coronary vasodilatation in both sized arteries (both, P<0.01). L-NMMA+catalase, L-NMMA+TEA, and L-NMMA+catalase+8-SPT significantly increased myocardial infarct area compared with the other four groups (control, L-NMMA, catalase, and 8-SPT; all, P<0.01). These results indicate that endogenous H2O2, in cooperation with NO, plays an important cardioprotective role in coronary I/R injury in vivo.

Acetylcholine↗

Evaluation of bioavailability of nitric oxide in coronary circulation by direct measurement of plasma nitric oxide concentration.

Although bioavailability of NO in the coronary circulation is commonly evaluated by acetylcholine (ACh)-induced vasodilation, a change in plasma NO concentration and its relation to the flow response after injection of ACh are still unknown. Thus, we directly measured the concentration of NO in the coronary sinus by using a catheter-type NO sensor for coronary sinus. An NO-sensitive sensor was located and fixed in a 4-Fr catheter with a soft tip for protection of vascular wall. After calibration with an NO-saturated pure water, the catheter-type NO sensor was located in the coronary sinus in anesthetized dogs. The coronary flow velocity (CFV) was measured with a Doppler guide wire. Intracoronary injection of ACh (0.4 and 1.0 microg/kg) increased plasma NO concentration in a dose-dependent manner (3-10 nM). Although ACh increased CFV by 95%, there was no significant difference between the two ACh doses. After ACh, the peak value of plasma NO concentration was observed significantly later than CFV. N(G)-methyl-L-arginine (NO synthase inhibitor) decreased basal NO concentration by 3 nM and suppressed the ACh-induced NO synthesis with no significant change in average peak velocity. We conclude that production of NO in the coronary circulation can be evaluated in the coronary sinus. Although ACh increases both CFV and NO concentration, CFV dose not reflect NO concentration in terms of magnitude and time course. Direct measurement of plasma NO concentration by the catheter-type NO sensor is useful to evaluate bioavailability of NO in the coronary circulation.

Acetylcholine↗

Beneficial effect of hydroxyfasudil, a specific Rho-kinase inhibitor, on ischemia/reperfusion injury in canine coronary microcirculation in vivo.

OBJECTIVES: We examined whether hydroxyfasudil, a specific Rho-kinase inhibitor, exerts cardioprotective effect on coronary ischemia/reperfusion (I/R) injury and, if so, whether nitric oxide (NO) is involved. BACKGROUND: Recent studies have demonstrated that Rho-kinase is substantially involved in the pathogenesis of cardiovascular diseases; however, it remains to be examined whether it is also involved in ischemia/reperfusion (I/R) injury. METHODS: Canine subepicardial small arteries (SA, >or=100 microm) and arterioles (A, <100 microm) were observed by a charge-coupled device intravital microscope during I/R. Coronary vascular responses to endothelium-dependent (acetylcholine, intracoronary [IC]) and -independent (papaverine, IC) vasodilators were examined after I/R under the following four conditions: control (n = 7), NO synthase inhibitor alone (N(G)-monomethl-L-arginine [L-NMMA], IC, n = 4), hydroxyfasudil alone (IC, n = 7), and hydroxyfasudil plus L-NMMA (n = 7). RESULTS: Hydroxyfasudil significantly attenuated serotonin (IC)-induced vasoconstriction of SA (-7 +/- 1% vs. 2 +/- 1%, p < 0.01). Coronary I/R significantly impaired coronary vasodilation to acetylcholine after I/R (SA, p < 0.05; and A, p < 0.01 vs. before I/R) and L-NMMA further reduced the vasodilation, whereas hydroxyfasudil completely preserved the responses. The vasoconstriction by L-NMMA after I/R was significantly improved by hydroxyfasudil in both-sized arteries (both p < 0.01). Expression of endothelial nitric oxide synthase (eNOS) protein in the ischemic endocardium of left anterior descending coronary artery area (as determined by Western blotting) significantly decreased (79 +/- 4%) compared with the nonischemic endocardium of LCX area (100 +/- 7%), which was improved by hydroxyfasudil (105 +/- 6%, p < 0.01). Hydroxyfasudil significantly reduced myocardial infarct size, and hydroxyfasudil with L-NMMA also reduced the infarct size compared with L-NMMA alone. CONCLUSIONS: Hydroxyfasudil exerts cardioprotective effects on coronary I/R injury in vivo, in which NO-mediated mechanism may be involved through preservation of eNOS expression.

1-(5-Isoquinolinesulfonyl)-2-Methylpiperazine↗

Exogenous NO suppresses flow-induced endothelium-derived NO production because of depletion of tetrahydrobiopterin.

Exogenous nitric oxide (NO) suppresses endothelium-derived NO production. We were interested in determining whether this is also the case in flow-induced endothelium-derived NO production. If so, then is the mechanism because of intracellular depletion of tetrahydrobiopterin [BH4; a cofactor of NO synthase (NOS)], which results in superoxide production by uncoupled NOS? Isolated canine femoral arteries were perfused with 100 microM S-nitroso-N-acetylpenicillamine (SNAP; an NO donor) and/or 64 microM BH4. Perfusion of SNAP suppressed flow-induced NO production, which was evaluated as a change in the slope of the linear relationship between perfusion rate and NO production rate (P < 0.02 vs. control; n = 7). Subsequent BH4 perfusion returned the slope to the control level. Concomitant perfusion of SNAP and BH4 retained the control-level NO production (n = 7). Concomitant perfusion of SNAP and 4,5-dihydroxy-1,3-benzene disulfonic acid (Tiron; 1 mM; a membrane-permeable superoxide scavenger) also retained the control-level NO production (n = 7), whereas perfusion of Tiron after SNAP could not return the NO production to the control level (P < 0.02 vs. control; n = 7). We also found a significant decrease in BH4 concentration in the endothelial cells after SNAP perfusion. In conclusion, these results indicate that exogenous NO suppresses the flow-induced, endothelium-derived NO production by superoxide released from uncoupled NOS because of intracellular BH4 depletion.

Animals↗

[Distinguishing between occluded and low-flow vessels with PROPELLER DWI sequence: a phantom study].

PURPOSE: To evaluate the ability of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted imaging (PROPELLER DWI) to distinguish between vessel occlusion and slow flow. MATERIALS AND METHODS: Using a flow phantom with various velocities (1.37 to 11.1 cm/s), the signal-intensity ratios of the phantom, with the intensity of no flow as baseline, were measured using the following imaging sequences: PROPELLER DWI, spin-echo T1-weighted imaging (SE T1WI), fast-spin-echo T2-weighted imaging (FSE T2WI), two-dimensional phase-contrast imaging (2D PC), and two-dimensional time-of-flight imaging (2D TOF). The b-factor of PROPELLER DWI was varied from 0 to 1000 s/mm(2). The velocity encoding of 2D PC was varied from 2 to 30 cm/s. RESULTS: At the lowest flow velocity (1.37 cm/s) , the signal-intensity ratio was 0.0075 for PROPELLER DWI (b-factor=1000 s/mm(2)), 1.8 for SE T1WI, 0.67 for FSE T2WI, 11 for 2D PC (velocity encoding=2 cm/s), and 1.4 for 2D TOF. The signal-intensity ratio was smallest for PROPELLER DWI, even when the reciprocals of the signal-intensity ratio of 2D PC or 2D TOF were considered. CONCLUSION: The results indicate that PROPELLER DWI provides the best signal intensity-ratio between vessel occlusion and slow flow. Although DWI with single-shot echo-planar imaging (EPI) or multi-shot EPI may have similarly high sensitivity for slow flow, these sequences do not have high spatial resolution or robustness to susceptibility artifacts. PROPELLER DWI would be a better choice for distinguishing between occluded and low-velocity arteries in the skull base or parasellar regions.

Blood Flow Velocity↗

[Imaging characteristics of PROPELLER T2-weighted imaging].

As the PROPELLER sequence is a combination of the radial scan and fast-spin-echo (FSE) sequence, it can be considered an FSE sequence with a motion correlation. However, there are some differences between PROPELLER and FSE owing to differences in k-space trajectory. We clarified the imaging characteristics of PROPELLER T2-weighted imaging (T2WI) for different parameters in comparison with usual FSE T2WI. When the same parameters were used, PROPELLER T2WI showed a higher signal-to-noise ratio (SNR) and lower spatial resolution than usual FSE. Effective echo time (TE) changed with different echo train lengths (ETL) or different bandwidths on PROPELLER, and imaging contrast changed accordingly to be more effective.

Artifacts↗

Measurement of acetylcholine-induced endothelium-derived nitric oxide in aorta using a newly developed catheter-type nitric oxide sensor.

Intra-aortic measurement of nitric oxide (NO) would provide valuable insights into NO bioavailability in systemic circulation and vascular endothelial function. In the present study, we thus developed a catheter-type NO sensor to measure intra-aortic NO concentration in vivo. An NO sensor was encased and fixed in a 4-Fr catheter. The sensor was then located in the thoracic aorta via the femoral artery through a 7-Fr catheter to measure intra-aortic plasma NO concentration in vivo in anesthetized dogs. Infusion of acetylcholine (10 microg/kg) increased base-to-peak plasma NO level in the aorta by 2.4+/-0.4 nM (n=7). After 20-min infusion of N(G)-methyl-L-arginine (NO synthase inhibitor), changes in plasma NO concentration in response to acetylcholine were attenuated significantly (1.8+/-0.4 nM, P<0.003, n=7). In conclusion, the newly developed catheter-type NO sensor successfully measured acetylcholine-induced changes in intra-aortic plasma concentration of endothelium-derived NO in vivo and demonstrated applicability to direct evaluation of intravascular NO bioavailability.

Acetylcholine↗

Hydrogen peroxide, an endogenous endothelium-derived hyperpolarizing factor, plays an important role in coronary autoregulation in vivo.

BACKGROUND: Recent studies in vitro have demonstrated that endothelium-derived hydrogen peroxide (H2O2) is an endothelium-derived hyperpolarizing factor (EDHF) in animals and humans. The aim of this study was to evaluate our hypothesis that endothelium-derived H2O2 is an EDHF in vivo and plays an important role in coronary autoregulation. METHODS AND RESULTS: To test this hypothesis, we evaluated vasodilator responses of canine (n=41) subepicardial small coronary arteries (> or =100 microm) and arterioles (<100 microm) with an intravital microscope in response to acetylcholine and to a stepwise reduction in coronary perfusion pressure (from 100 to 30 mm Hg) before and after inhibition of NO synthesis with N(G)-monomethyl-L-arginine (L-NMMA). After L-NMMA, the coronary vasodilator responses were attenuated primarily in small arteries, whereas combined infusion of L-NMMA plus catalase (an enzyme that selectively dismutates H2O2 into water and oxygen) or tetraethylammonium (TEA, an inhibitor of large-conductance K(Ca) channels) attenuated the vasodilator responses of coronary arteries of both sizes. Residual arteriolar dilation after L-NMMA plus catalase or TEA was largely attenuated by 8-sulfophenyltheophylline, an adenosine receptor inhibitor. CONCLUSIONS: These results suggest that H2O2 is an endogenous EDHF in vivo and plays an important role in coronary autoregulation in cooperation with NO and adenosine.

Adenosine↗

In vivo visualization of subendocardial arteriolar response in renovascular hypertensive hearts.

Time-sequential responses to endothelium-dependent and -independent vasodilators and angiotensin-converting enzyme (ACE) inhibitors were studied in the subendocardial arterioles (Endo) of canine renovascular hypertension (HT) compared with subepicardial arterioles (Epi; both <120 microm) by charge-coupled device intravital microscope. Vascular responses to acetylcholine, papaverine, and cilazaprilat were compared between normotensive (NT) and HT dogs [4 wk and 12 wk of HT (4wHT and 12wHT)]. The acetylcholine-induced vasodilation of Endo in both 4wHT and 12wHT was smaller than that of NT (both P < 0.01 vs. 4wHT and 12wHT), and that of Epi was smaller than that of NT only in 12wHT (P < 0.05). The papaverine-induced vasodilation of Endo, but not Epi, was impaired only in 12wHT (both P < 0.01 vs. NT and 4wHT). Vasodilation by cilazaprilat remained unchanged at 4wHT and 12wHT in both Epi and Endo. In conclusion, at the early stage, the endothelium-dependent response of Endo was impaired, whereas at the later stage, the endothelium-dependent and -independent responses of Endo and the endothelium-dependent response of Epi were impaired. However, the vasodilatory responses to the ACE inhibitor were maintained in both Endo and Epi of HT.

Acetylcholine↗

Dynamic changes in three-dimensional architecture and vascular volume of transmural coronary microvasculature between diastolic- and systolic-arrested rat hearts.

BACKGROUND: The phase difference of coronary arterial and venous flows indicates the importance of intramyocardial capacitance vessels in storing diastolic flow and in discharging volume in systole. However, the anatomic and functional characteristics of the capacitance vessels are unclear. We aimed to clarify those characteristics with their transmural difference by 3D visualization of transmural microvessels under diastole and systole. METHODS AND RESULTS: We performed complete intracoronary filling of a contrast medium into Langendorff's Wistar rat hearts under (1) St Thomas-perfused diastolic arrest (D-mode) and (2) BaCl(2)-induced systolic arrest (S-mode). Precise transmural 3D architectures of capillaries and of pre- and post-capillary microvessels (ie, microvessels larger than capillaries) were visualized clearly with a confocal laser scanning microscope and x-ray microcomputed tomography (microCT), respectively. Vascular volume fraction (VF) and systolic-induced VF reduction rate from D- to S-mode were analyzed. The net capillary VF in D-mode (20.4 +/- 0.9%) was 10 times that of larger microvessels and was reduced in S-mode by 32% without capillary collapse. Systolic-induced VF reduction rate was smaller in capillaries than in larger microvessels (48%; P<0.05). The larger microvessel VF in D-mode (2.2 +/-0.2%) was reduced in S-mode, accompanied by complicated 3D deformation. CONCLUSIONS: Capillaries were relatively resistant to the systolic extravascular compression compared with pre- and post-capillary microvessels, conveniently beneficial for the myocardial oxygen delivery throughout a cardiac cycle. Nevertheless, a larger change in the absolute volume of capillaries may function as effective capacitance. On one hand, the pre- and post-capillary microvessels showed a larger phasic change in resistance, which may function to maintain the capillary patency during systole.

Animals↗