[Physiological phenomena and excluded volume effect--macromolecule activity coefficient].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Masaru Sogami.
Explore the source record for details and available documents.
Sentinel lymph node biopsy (SLNB) is an important technique for detecting axillary lymph node metastasis in breast carcinoma patients. However, false-negative results are a problem. Equivalent cross-relaxation rate (ECR) imaging (ECRI) is a measurement method that can be used to quantitatively evaluate a change in the structural organization of lymph nodes by magnetic resonance imaging (MRI). We performed axillary ECRI in an attempt to decrease the false-negative results of SLNB. Regions without metastases showed a higher ECR value. On the other hand, regions with metastases showed a lower ECR value. The ECR images were compared with macroscopic histology images in which the presence or absence of axillary lymph node metastasis could be evaluated. ECRI is a potentially useful method for evaluating the efficacy of SLNB.
Saturation transfer phenomena from irradiated protein protons to observed water protons in packed human red blood cells (RBCs) with normal or unstable hemoglobin (Hb), i.e. Hb Yokohama and Hb Koeln, were studied using intermolecular cross-relaxation rates [CR; 1/T(IS)(H(2)O)], action spectra [[1-(I(infinity)/I(0))] vs f(2) (ppm), where I(0) and I(infinity) are the longitudinal magnetization of observed water protons before and after long-time f(2)-irradiation, respectively], CR spectra [CR vs f(2) (ppm)] and CR ratio vs f(2) (ppm) with f(2)-irradiation from -100 to 100 ppm at gammaH(2)/2pi of 69 or 250 Hz. RBCs (Hb Yokohama) exhibited many large Heinz bodies and strongly impaired filterability, while RBCs (Hb Koeln) showed few microscopically typical Heinz bodies and virtually normal filterability. However, increases in CR values for RBCs (Hb Koeln) and RBCs (Hb Yokohama), monitored by f(2)-irradiation below approximately -6 and above approximately 14 ppm, clearly indicated marked increases in association or aggregation of unstable Hb in RBCs compared with those in normal RBCs. CR values, monitored between approximately 0 and approximately 10 ppm, were related to not only association or aggregation of unstable Hb but also amounts of water in RBCs. Aggregation or association of unstable Hb exhibited greater effects on CR values compared with those of methemoglobin formation.
In the breast carcinamas, sentinel lymph node biopsy (SLNB) attracts attention as technique to be settled by axillary lymph node metastasis, but existence of a false negative case is a problem. Equivalent cross relaxation rate image (ECRI) is the measurement method that we can evaluate a change of organization structure quantitatively by magnetic resonance imaging. We executed axillary ECRI as a purpose with decreasing a false negative case of SLNB. ECRI related to a macroscopic image, and it was possible to evaluate yes or no of axillary lymph node metastasis. ECRI is the useful method to evaluate adaptability of SLNB.
BACKGROUND: Human serum albumin (HSA) is a mixture of human mercaptalbumin (HMA, reduced form) and nonmercaptalbumin (HNA, oxidized form). METHODS: We have developed a convenient high-performance liquid chromatographic (HPLC) system for the separation of HSA into HMA and HNA, and studied the mercapt<==>nonmercapt conversion (i.e., dynamic change in the redox state) of HSA. Examination of long-term sample preservation temperature on the redox state of HSA is of fundamental importance for analysis of defense systems against oxidants in humans. RESULTS: The HMA fraction of HSA (f(HMA)) was markedly decreased, i.e., the redox state of HSA samples was more oxidized, when they were kept even at -20 degrees C for 170 days. Moreover, the redox states of five commercial HSA products were analyzed and the results were compared with those for normal control subjects. CONCLUSIONS: Surprisingly, marked decreases in f(HMA) value for all commercial HSA products were observed.
The values of equivalent cross-relaxation rate (ECR) correlated well with [i] water conditions in various copolymer gels and [ii] nature of malignant cells with regard to nuclear dysplasia and mitotic potential in breast carcinomas. The synthetic copolymer gels composed of any two or three monomers among 2-hydroxyethyl methacrylate (HEMA), glycidyl methacrylate (GMA), N-vinyl-2-pyrrolidinone (N-VP), methyl methacrylate (MMA) and benzyl methacrylate (BMA). The ECR measurement was performed by using an off-resonance saturation pulse under conventional field-echo imaging at frequency within +/- 75 ppm apart from the water resonance frequency. The ECR values were readily to determine and non-time consuming parameter for cross relaxation rate. The ECR values at the frequency offset by 7-ppm (ECR-7) were divided the sample gels two classes, which must correspond to hydrophilic or hydrophobic ones. The sensitivity in the gels was nearly equivalent to the cross-relaxation rate itself. In the breast carcinomas, the ECR-7 correlates with the nature of malignant cells with regard to nuclear dysplasia and mitotic potential. The ECR-7 is better or more accurate than the STR-7 because the SDNRs between carcinoma and glandular tissue increased by approximately 50% on the ECR-7 compared with the STR-7. Thus the ECR values could be a new parameter for malignancy and cell proliferative activity of the breast carcinomas with non-invasive modalities by magnetic resonance imaging.