PubMed Health⌕ Search

Biomedical subjects

Masatoshi Akiyama

Publications and source records attributed to Masatoshi Akiyama.

14 recordsLinked to original sources

Impact of left atrial appendage exclusion on left atrial function.

OBJECTIVES: We sought to investigate the short-term and midterm effects of left atrial appendage exclusion on left atrial function. Left atrial appendage exclusion is considered a possible therapeutic option for stroke prevention in patients with atrial fibrillation. Favorable outcomes have encouraged widespread use of left atrial appendage exclusion for cardiac surgical patients-even for patients in sinus rhythm who have stroke risk factors; however, the chronic effects on left atrial function of left atrial appendage exclusion are unclear. METHODS: Nineteen mongrel dogs (29.7 +/- 5.2 kg) in sinus rhythm were studied. The Doppler signals from the pulmonary venous flow, transmitral flow, and tissue Doppler imaging of mitral annular motion were obtained before and after left atrial appendage exclusion. Dogs were evaluated in the same manner at 7 days (n = 2), 30 days (n = 7), or 90 days (n = 10) after left atrial appendage exclusion. RESULTS: Except for a significant increase in early diastolic transmitral flow velocity after left atrial appendage exclusion (P = .01), no significant differences were found in any parameters related to the transmitral flow and tissue Doppler imaging measurements throughout follow-up. The systolic components of pulmonary venous flow at follow-up revealed a significant reduction relative to baseline (peak systolic velocity P < .0001, systolic velocity-time integral P < .0001), despite the lack of significant changes in left atrial pressure, left ventricular volume, and stroke volume. CONCLUSION: Left atrial appendage exclusion may affect left atrial reservoir function in the short-term and midterm periods. Further long-term studies with more clinically relevant models are needed.

Animals↗

Ventral cardiac denervation increased right coronary arterial blood flow.

BACKGROUND: Cardiac denervation accompanied with coronary artery bypass surgery has been widely performed for the treatment of vasospastic angina associated with atherosclerotic coronary artery disease. However, the effect of cardiac denervation on phasic coronary blood flow patterns of the left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX) and right coronary artery (RCA) remains unknown. This study aimed to investigate the effect of cardiac denervation on phasic coronary blood flow patterns of the LAD, LCX and RCA. METHODS: Phasic coronary blood flow patterns were analyzed using three flow probes placed around the LAD, LCX and RCA with and without LAD stenosis. Ventral cardiac denervation (VCD) was performed in 8 pigs, and 16 pigs were used as control subjects. Autonomic activities before and after the VCD were quantified by wavelet analysis of heart rate variability. RESULTS: The mean LAD flow (34.4+/-9.4 to 32.6+/-7.1 ml/min, p=0.638) and mean LCX flow (26.3+/-10.2 to 27.2+/-6.0 ml/min, p=0.825) showed no significant change after VCD, while the mean RCA flow (31.3+/-9.0 to 38.2+/-11.2 ml/min, p=0.003) significantly increased. The hemodynamic variables in the VCD group were well maintained after creation of LAD stenosis, while they deteriorated in the control group. The low-frequency components, high-frequency components and their ratio did not change after VCD. CONCLUSIONS: VCD prevented the deterioration of cardiac function after creation of an LAD stenosis and resulted in an increase of the mean RCA flow. VCD did not affect autonomic nervous system activity.

Angina Pectoris↗

Up-regulation of matrix metalloproteinase-2 and membrane-type 1-matrix metalloproteinase were coupled with that of type I procollagen in granulation tissue response after the onset of aortic dissection.

The pathophysiological significance of matrix metalloproteinases (MMPs) in aortic dissection remains poorly understood. The purpose of the present study is to clarify the significance of MMPs in aortic dissection. The activities and distributions of MMP-2, membrane-type 1-MMP (MT1-MMP), and MMP-9 were evaluated by gelatin zymography, immunohistochemistry, and in situ hybridization in 29 patients and seven autopsy cases. To assess if these MMPs are related to a tissue remodeling process, we compared the expression of these MMPs with that of type I procollagen and platelet-derived growth factor receptor beta chain (PDGF Rbeta). Patients were divided into three groups based on histological findings: acute, intermediate, and healed groups. The most remarkable changes were observed in the intermediate group, in which MMP-2 activity peaked and tissue expression of mRNAs for MMP-2 and MT1-MMP were observed in spindle-shaped cells in the neointima, organizing thrombus, and the adventitia. These expression patterns were essentially coupled with those of type I procollagen mRNA and PDGF-Rbeta protein. The association of MMP-2, MT1-MMP, type I procollagen, and PDGF-Rbeta suggests that MMP-2 and MT1-MMP could be involved not only in the degradation of aortic tissue but also in tissue remodeling, which may be associated with the healing process.

Aged↗

Evaluation of a novel device for left atrial appendage exclusion: the second-generation atrial exclusion device.

BACKGROUND: The left atrial appendage is a frequent source of thromboemboli in patients with atrial fibrillation. Exclusion of the left atrial appendage may reduce the risk of stroke in patients with atrial fibrillation. The atrial exclusion device, previously developed to perform left atrial appendage exclusion on a beating heart, was modified to accommodate different anatomic patterns of the human left atrial appendage and to ensure uniform pressure and occlusion. The purpose of this study was to evaluate this second-generation atrial exclusion device during a midterm period in a canine model. METHODS: Ten mongrel dogs (mean weight 28.9 +/- 4.6 kg) were used in this study. The atrial exclusion device, constructed from two parallel and rigid titanium tubes and two nitinol springs with a knit-braided polyester fabric, was implanted at the base of the left atrial appendage through a left thoracotomy on a beating heart using a specially designed delivery tool. Dogs were evaluated at 30 days (n = 4) and 90 days (n = 6) by epicardial echocardiography, left atrial and coronary angiography, gross pathology, and histologic inspection. RESULTS: Device implantation was performed without complications in all dogs. Complete left atrial appendage exclusion without device migration or hemodynamic instability was confirmed, and there was no damage to the left circumflex artery or pulmonary artery. Macroscopic and microscopic assessments revealed favorable biocompatibility during midterm follow-up. CONCLUSION: The atrial exclusion device enabled rapid, reliable, and safe exclusion of the left atrial appendage. Clinical application may provide a new therapeutic option for reducing the risk of stroke in patients with atrial fibrillation.

Animals↗

Phasic coronary blood flow pattern during a continuous flow left ventricular assist support.

OBJECTIVE: Continuous flow left ventricular assist devices (LVADs) have been introduced and tested as a bridge to heart transplantation, bridge to recovery, and destination therapy, and several studies have been conducted to assess the physiologic effects of continuous flow LVADs. However, the effect of reduced pulsatility on the phasic coronary blood flow pattern is unknown. The aim of this study was to investigate the phasic coronary blood flow patterns during continuous flow LVAD support. METHODS: Phasic coronary blood flow patterns and hemodynamic data were analyzed using three flow probes placed around the left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX), and the right coronary artery (RCA) in 16 pigs before and after initiating the LVAD support with or without creating LAD stenosis. RESULTS: The total coronary blood flow (TCBF, 112.8+/-31.4 mL/min) gradually decreased when the continuous flow LVAD support increased to 2.0 L/min (110.7+/-29.0 mL/min, P = 0.571), 2.5 L/min (103.7+/-26.1 mL/min, P = 0.079), and 3.0 L/min (101.5+/-27.2 mL/min, P = 0.027) because of decreases in LAD flow and LCX flow. LVAD support caused decrease in systolic and peak systolic LAD flow, LCX flow, and RCA flow, whereas diastolic RCA flow increased. In the presence of LAD stenosis, the TCBF (97.7+/-36.1 mL/min) decreased when the continuous flow LVAD support increased to 2.0 L/min (83.9+/-22.1 mL/min, P = 0.029), 2.5 L/min (83.2+/-25.2 mL/min, P = 0.012), and 3.0 L/min (87.6+/-23.4 mL/min, P = 0.005) because of decreases in LCX flow. CONCLUSION: Use of a continuous flow LVAD decreased TCBF, LAD flow, and LCX flow secondary to reduced systolic LAD flow and LCX flow, and decreased TCBF and LCX flow in the presence of LAD stenosis. These findings are potentially relevant to understanding the physiology of myocardial blood perfusion during continuous flow LVAD support especially in patients with coronary artery disease.

Animals↗

A novel device for left atrial appendage exclusion.

OBJECTIVE: The left atrial appendage is a frequent source of thromboemboli in patients with atrial fibrillation. Exclusion or excision of the left atrial appendage may reduce the risk of stroke in patients with atrial fibrillation. We evaluated the ability of a novel device to exclude the left atrial appendage during early and intermediate follow-up periods in a canine model. METHODS: Eight mongrel dogs (mean weight 29.1 +/- 4.0 kg) were used in this study. The occlusion device, constructed from 2 stainless steel strips covered with a knit braided polyester fabric, was implanted at the base of the left atrial appendage through a left thoracotomy on a beating heart. Dogs were evaluated at 7 days (n = 2), 30 days (n = 2), and 90 days (n = 4) by epicardial echocardiography, left atrial angiography, histologic inspection, and gross pathology. RESULTS: Device implantation was performed without complications in all animals. Complete exclusion of the left atrial appendage from the circulation was confirmed acutely and chronically by echocardiographic and angiographic evaluations. There was no device migration or damage to adjacent structures. CONCLUSION: This novel device enables rapid, reliable, and safe exclusion of the left atrial appendage. The device provides a new therapeutic option for reducing the risk of stroke in patients with atrial fibrillation.

Animals↗

Fatal delayed esophageal rupture following aortic clamping for treatment of Stanford type B dissection.

A 65-year-old man underwent a thromboexclusion operation for management of chronic Stanford type B dissecting aneurysm in 1991. However, long-term follow-up CT scans after the operation revealed that the ascending aorta gradually enlarged and was eventually complicated by recurrent aortic dissection. The patient complained of frequent bloody sputum, whereas chest roentogenography showed no pulmonary abnormalities. Subsequent swallow esophagogram demonstrated that the upper esophagus was deviated to the right and the middle esophagus was greatly compressed by the aortic clamp. Esophageal endoscopy showed a bloody inner surface and marked swelling of the middle esophagus. The patient eventually died of massive hematemesis in 2001. We describe the imaging features of unanticipated complications such as recurrent dissecting aneurysm or impending esophageal rupture. Furthermore, we discuss the cause of hematemesis and document that the aortic clamp migrated and resulted in development of a recurrent aneurysmal dissection, which in turn resulted in esophageal rupture with aneurysmal disruption.

Aortic Dissection↗

In vitro performance of the novel coronary sinus AutoRetroPerfusion Cannula.

Myocardial salvage through coronary sinus intervention has been documented. The AutoRetroPerfusion Cannula is a novel device that is able to perfuse the coronary bed retrogradely through the coronary sinus with arterial blood generated from a peripheral artery with no need for a pump. The cannula consists of a distal end that, once secured in the coronary sinus, opens an umbrella-like membrane to create pressure in the coronary sinus, and at the same time has small channels directed backwards to the right atrium to provide pressure relief. The cannula is introduced from the axillary vein under local anesthesia and the proximal end, which consists of a graft, is anastomosed to the axillary artery to start autoperfusion once the distal end is secured in the coronary sinus and the occluding membrane is open. The AutoRetroPerfusion Cannula was tested in the in vitro mock loop under 50-120 mm Hg of proximal pressure and 50, 100, and 150 ml/min of total flow in the cannula. We were able to achieve the nominal design point of 40-80 mm Hg of distal pressure and 50-150 ml/min of distal flow by adjusting the number, diameter, and length of the small backwards channels.

Biomedical Engineering↗

Development of a small implantable right ventricular assist device.

The purpose of this program is to design, develop, and clinically evaluate a new, implantable right ventricular assist device (RVAD) that can be used as a component of an implantable biventricular assist device for patients with severe biventricular heart failure. The initial phase of this program resulted in a prototype RVAD, named DexAide, a modified version of the CorAide left ventricular assist device. In vitro testing was performed in a stand-alone circuit and in a true RVAD mode to evaluate pump performance. Pump flow and power were measured under various afterload and pump speed conditions. The pump performance requirements of 2 to 6 l/min and a pressure rise of 20 to 60 mm Hg were successfully met with pump speeds between 1,800 and 3,200 rpm. The nominal design point of 4 l/min and 40 mm Hg pressure rise was achieved at 2,450 +/- 70 rpm with a power consumption of 3.0 +/- 0.2 W. The initial in vitro testing met the design criteria for the new DexAide RVAD. Initial in vivo testing is under way, which will be followed by preclinical readiness testing and a pilot clinical trial in this 5-year program.

Biomedical Engineering↗

Performance and reliability of the CPB/ECMO Initiative Forward Lines Casualty Management System.

The Cleveland Clinic Foundation CPB/ECMO Initiative Forward Casualty Management System is an economical, compact, transportable, disposable system designed to permit a rapid expansion of trauma management services requiring cardiopulmonary bypass (CPB) or extracorporeal membrane oxygenation (ECMO) pulmonary support. The system, composed of a rotary blood pump, a pump motor driver, and an electronic control console as the blood pumping subsystem, also includes commonly used compatible commercial oxygenators, venous reservoirs, and cannulae. In vitro durability testing accumulated over 100 hours without failure. In vivo reliability was tested in 10 calves under general anesthesia during 6 hours of CPB and ECMO under full heparinization at nominal operating conditions of 4-5 l/min and 2-4 l/min blood flow respectively, and mean arterial pressures between 65 and 100 mm Hg. A mean time to failure of 57 hours was reached during the animal series. Results of these test series demonstrated that this system has the capability to reliably operate during a 6-hour conventional CPB or ECMO procedure, while providing flexibility and ease of use for the operator.

Animals↗

MagScrew TAH: an update.

The MagScrew Total Artificial Heart (TAH) system is the result of a close collaboration among the Cleveland Clinic Foundation, Foster Miller Technologies, Wilson Greatbatch Ltd, and Whalen Biomedical Inc. The system components are the thoracic blood pumping unit with attached compliance chamber and refill port, implantable electronic control unit, implantable battery pack, transcutaneous energy transmission system, external battery pack, and a telemetry system for communication with the electronic control unit. System in vitro tests are underway for system characterization and durability demonstration, whereas in vivo tests were conducted to evaluate system performance and biocompatibility under physiologic conditions. The passively filling pump uses a left master alternate left and right ejection control mode and has a Starling law-like response to venous pressure. The in vitro tests documented excellent hydraulic pump performance with high device output of over 9 l/min at left atrial pressures below 12 mm Hg. Atrial balance was well maintained under all test conditions. The in vivo tests demonstrated good biocompatibility without use of anticoagulant therapy. Experimental durations have ranged between 0 and 92 days. Postexplant evaluation of tissue samples did not reveal any sign of thromboembolic events or tissue damage due to device operation.

Animals↗

Initial in vivo evaluation of the DexAide right ventricular assist device.

Despite the increasing use of left ventricular assist devices for patients with end-stage congestive heart failure, no implantable, centrifugal right ventricular assist devices (RVADs) are available for those patients with significant right ventricular failure. The DexAide RVAD was developed to provide an implantable RVAD option to surgeons. The aim of this study was to evaluate pump performance in an acute in vivo model. The DexAide RVAD, developed as a modified CorAide left ventricular assist device, was implanted between the right ventricle and the pulmonary artery in four healthy calves. Pump speed was varied from 1800 rpm to 3600 rpm. RVAD performance was analyzed acutely at baseline and under conditions of low circulating volume, high contractility, high pulmonary arterial pressure, vasodilation, and low contractility. Pump flow was well maintained even under conditions of high pulmonary arterial pressure and vasodilation, with the exception of low circulating volume. Under all conditions, pulmonary arterial pressures were not affected by changing pump speed. The DexAide RVAD demonstrated acceptable hemodynamic characteristics for use as an implantable RVAD in the initial acute studies. Further studies are ongoing to examine the biocompatibility of the pump under chronic conditions.

Animals↗

Replacement of the left-side valves of an implanted total artificial heart.

The MagScrew total artificial heart (TAH) is under development. Despite its anticipated durability and reliability, the possibility of a bioprosthetic valve malfunction exists. As a result, the potential for valve replacement surgery, instead of device replacement, would be desirable after a TAH implant. In two of our 90-day animal experiments, we successfully replaced the left-side valves through a left thoracotomy opposite to the right-sided incision site for the initial TAH implant. The results of these cases suggest that the left-side valves could also be replaced through a left thoracotomy approach in humans. To confirm the ability to access the left-side valves in humans, four human cadaver studies were performed with the use of a mock pump designed for human application. This report describes the operative techniques for left-side valve replacement in animals and discusses the advantages of a left thoracotomy in clinical situations, based on results from the human cadaver studies.

Animals↗

Progress in the development of the DexAide right ventricular assist device.

The DexAide right ventricular assist device (RVAD) is an implantable centrifugal pump modified from the CorAide left ventricular assist device. As previously published, in vitro performance testing of the DexAide RVAD has met design criteria, and the nominal operating condition of 4 l/min and 20 mm Hg pressure rise was achieved at 2,000 rpm, with a power consumption of 1.9 watts. In vivo studies in 14 calves have demonstrated acceptable hemodynamic characteristics. The calf inflow cannula design is still evolving to minimize depositions on the cannula observed in most experiments. Fitting studies were performed in 5 cadavers and 2 patients to reconfigure the cannulae for use in humans. The design and development of external electronics have been completed for the stand-alone RVAD system, and verification tests are under way in preparation for preclinical tests. Work on the external electronics design for the biventricular assist system is ongoing. In conclusion, the initial in vitro and in vivo studies have demonstrated acceptable hemodynamic characteristics of the DexAide RVAD. The design and development of the external electronic components for the stand-alone RVAD system have been completed. The calf inflow cannula is being redesigned, and chronic in vivo tests are under way.

Animals↗