PubMed Health⌕ Search

Biomedical subjects

Massimo Midiri

Publications and source records attributed to Massimo Midiri.

At least 19 recordsLinked to original sources

Qualitative and quantitative evaluation of solitary thyroid nodules with contrast-enhanced ultrasound: initial results.

To assess the feasibility of contrast-enhanced ultrasound (CEUS) of the thyroid gland and to evaluate the potential of this method for characterising solitary thyroid nodules.18 patients affected by solitary thyroid nodules (size range: 0.6 to 3.6 cm; mean: 1.8 cm) confirmed by surgery (nine papillary carcinomas, four follicular carcinomas, three hyperplasias, one follicular adenoma and one Plummer's adenoma) underwent pulse inversion US at low M.I. (0.06 to 0.08) after i.v. injection of a 2.4-mL bolus of SonoVue. Baseline echogenicity and the dynamic enhancement pattern of each nodule, in comparison with adjacent thyroid parenchyma, were assessed. Signal intensity values on grey-scale images were also calculated at baseline, 30 s, 60 s and 120 s after SonoVue administration. Following administration of SonoVue, malignant nodules showed absent (4 out of 13), faint dotted (4 out of 13) and diffuse (5 out of 13) contrast enhancement, in this last case inhomogeneous (4 out of 5 cases) or homogeneous (1 out of 5). Benign nodules showed diffuse contrast enhancement, both homogeneous (3 out of 5) and heterogeneous (2 out of 5). Quantitative data have confirmed subjective findings, but CEUS never modified precontrast analysis. CEUS of thyroid gland is a feasible technique, but overlapping findings seem to limit the potential of this technique in the characterization of thyroid nodules.

Adult↗

Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.

PURPOSE: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. MATERIALS AND METHODS: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. RESULTS: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P < 0.0001). CONCLUSION: Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value.

Adolescent↗

High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400.

OBJECTIVE: The objective of this study was to compare intracoronary attenuation on 16-row multislice computed tomography (16-MSCT) coronary angiography using 2 contrast materials (CM) with high iodine concentration. MATERIAL AND METHODS: Forty consecutive patients (29 male, 11 female; mean age, 61+/-11 years) with suspected coronary artery disease were randomized to 2 groups to receive 100 mL of either iopromide 370 (group 1: Ultravist 370, 370 mg iodine/mL; Schering AG, Berlin, Germany) or iomeprol 400 (group 2: Iomeron 400, 400 mg iodine/mL; Bracco Imaging SpA, Milan, Italy). Both CM were administered at a rate of 4 mL/s. All patients underwent 16-MSCT coronary angiography (Sensation 16; Siemens, Germany) with collimation 16 x 0.75 mm and rotation time 375 ms. The attenuation in Hounsfield units (HU) achieved after each CM was determined at regions of interest (ROIs) placed at the origin of coronary arteries and on the ascending aorta, descending aorta, and pulmonary artery. Differences in mean attenuation in the coronary arteries and on the ascending aorta, descending aorta, and pulmonary artery were evaluated using Student t test. RESULTS: The mean attenuation achieved at each anatomic site was consistently greater after iomeprol 400 than after iopromide 370. At the origin of coronary arteries, the mean attenuation after iomeprol 400 (340+/-53 HU) was greater (P<0.05) than that after iopromide 370 (313+/- 42 HU). Similar findings were noted for the mean attenuation in the ascending aorta, descending aorta, and pulmonary artery. CONCLUSION: The intravenous administration of iomeprol 400 provides higher attenuation of the coronary arteries and of the great arteries of the thorax as compared with iopromide 370 using the same injection parameters.

Adult↗

Evaluation of the efficacy of oral deferiprone in beta-thalassemia major by multislice multiecho T2*.

OBJECTIVES: Oral deferiprone (L1) appears to be promising in the treatment of beta-thalassemia major (TM) patients. T2* magnetic resonance imaging (MRI) with a single measurement in the mid-ventricular septum was validated as a quantitative evaluation of myocardial iron overload. Previous studies suggested a marked heterogeneity of iron distribution in the myocardium. We set up a multislice multiecho T2* MRI for the detection of this heterogeneity. The aim of our study was to investigate differences between the L1 vs. the subcutaneous desferrioxamine (DF)-treated patients using this new approach. METHODS: Thirty-six beta-TM patients (age 29 +/- 8 yr) underwent MRI. Eighteen patients received long-term L1, and 18 other patients matched for age and sex received DF. T2* multiecho sequences on three short axis views of the left ventricle were obtained and analyzed by custom-made software. In each slice, the myocardium was automatically segmented into four segments. Cine-dynamic images were also obtained to evaluate biventricular function. RESULTS: For multislice T2* technique, the coefficient of variation for intra- and inter-observer, and inter-study reproducibility was 3.9%, 4.7%, and 5.5%, respectively. The global heart T2* value was significantly higher in the L1 vs. DF group (35 +/- 7 vs. 27 +/- 2 ms; P = 0.02). The number of segments with normal T2* value (>20 ms) was significantly higher in the L1 vs. the DF group (11 +/- 1 vs. 8 +/- 5 segments; P = 0.03). We did not detect significant differences in biventricular function parameters. CONCLUSIONS: This new approach confirms that L1 could be more effective than DF in removal of myocardial iron.

Adult↗

Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing.

OBJECTIVE: The objective of our study was to compare diagnostic accuracy of MDCT coronary angiography in a population of patients with mild heart rhythm irregularities before and after editing the ECG. SUBJECTS AND METHODS: Thirty-eight patients who underwent MDCT coronary angiography and conventional coronary angiography were enrolled in the study. The inclusion criterion was the presence of mild heart rhythm irregularities (i.e., premature beats; atrial fibrillation; mistriggering; or low heart rate, defined as 40 beats per minute or less) during the scan. All patients underwent MDCT with the following parameters: 16 detectors; collimation, 0.75 mm; gantry rotation time, 375 msec; 120 kV; and effective milliampere-second setting, 500-600. Images were reconstructed in two settings: before ECG editing and after ECG editing (i.e., arbitrary modification of temporal windows within the cardiac cycle at the site of mild heart rhythm irregularities). Data sets were scored for the presence of significant stenoses (> or = 50% lumen reduction) in coronary segments > or = 2 mm diameter. The results of the two groups were compared with a McNemar test, and a p value of less than 0.05 was considered significant. RESULTS: The sensitivity, specificity, and negative and positive predictive values of MDCT coronary angiography for the detection of significant stenoses before and after ECG editing were 63% (41/65) and 92% (78/85); 97% (251/260) and 96% (305/317); 87% (62/71) and 87% (81/93); 91% (251/275) and 97% (305/313), respectively (p < 0.05). The proportion of nonassessable segments was reduced from 17% (70/416) before ECG editing to 2% (10/416) after. CONCLUSION: ECG editing significantly improves diagnostic accuracy in a selected population of patients with mild heart rate irregularities.

Atrial Fibrillation↗

Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography.

OBJECTIVE: The purpose of this study was to investigate whether the amount of intracoronary attenuation influences the diagnostic accuracy of MDCT coronary angiography in the detection of clinically significant stenosis. MATERIALS AND METHODS: One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent MDCT of the heart and conventional coronary angiography were retrospectively selected. The population was divided into two groups depending on median (326 H) coronary vascular enhancement (i.e., low attenuation and high attenuation). The diagnostic accuracy of MDCT for the detection of clinically significant coronary artery lesions (> or = 50% lumen reduction) in both groups was compared with that of quantitative coronary angiography. RESULTS: The sensitivity of MDCT was 90% and 93% for the low- and high-attenuation groups, respectively. The specificity was 95% and 97%. CONCLUSION: Greater intracoronary attenuation leads to higher diagnostic accuracy in the detection of coronary artery stenosis with MDCT.

Angina Pectoris↗

Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates.

PURPOSE: Assess the effect of heart rate on diagnostic accuracy for the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). MATERIAL AND METHODS: About 120 patients (105 males; 59+/-11 years) with suspected coronary artery disease who underwent conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA (Sensation 16, Siemens, Germany), with the following protocol: collimation 16 x 0.75 mm, gantry rotation time 420 ms, feed/rotation 3.0 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol (Visipaque 320 mg l/ml, Amersham, UK) at 4 ml/s and the delay was defined with a bolus tracking technique. In all patients the mean heart rate (HR) during the scan was used as a criteria to divide the population in two groups of 60 patients each. In one group (Low HR) the 60 patients with lower heart rates, and in the other group (High HR) the patients with higher heart rates. In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (>or=50% lumen reduction) was evaluated in vessels >or=2 mm of diameter using quantitative CA as reference standard. The difference in diagnostic accuracy were compared with a Chi(2) test and a p<0.05 was considered significant. RESULTS: There was no significant difference between the two groups regarding age, gender, weight, mean intravascular attenuation, and calcium score. Overall 1,310 (652 for Low HR and 658 for High HR) segments with 219 (105 for Low HR and 114 for High HR) significant lesions were available for the analysis. The average heart rate was 52+/-4 HU and 63+/-5 HU for Low HR and High HR, respectively (p<0.001). The sensitivity and specificity were 92 and 96% for Low HR and 90 and 92% for High HR (p<0.05). There were 22 vs. 44 false positives, and 8 vs. 12 false negatives in the Low HR and High HR, respectively. CONCLUSION: Increasing HR significantly deteriorates diagnostic accuracy in MSCT-CA.

Chi-Square Distribution↗

Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with multislice computed tomography angiography.

One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent multislice computed tomography of the heart and conventional coronary angiography were retrospectively selected. The population was divided into 2 groups depending on their calcium score (CS) (e.g., low CS and high CS). The diagnostic accuracy of multislice computed tomographic scans for detecting significant lesions (>50% lumen reduction) in both groups was compared with quantitative coronary angiography. The sensitivity and specificity of multislice computed tomography were 90% and 92%, and 97% and 91% for low and high CS groups, respectively.

Calcinosis↗

3D reconstruction techniques made easy: know-how and pictures.

Three-dimensional reconstructions represent a visual-based tool for illustrating the basis of three-dimensional post-processing such as interpolation, ray-casting, segmentation, percentage classification, gradient calculation, shading and illumination. The knowledge of the optimal scanning and reconstruction parameters facilitates the use of three-dimensional reconstruction techniques in clinical practise. The aim of this article is to explain the principles of multidimensional image processing in a pictorial way and the advantages and limitations of the different possibilities of 3D visualisation.

Audiovisual Aids↗

Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography.

Assessment of attenuation (measured in Hounsfield units, HU) of human coronary plaques was performed using multislice computed tomography (MSCT) in an ex vivo model. In three ex vivo specimens of left coronary arteries in oil, MSCT was performed after intracoronary injection of four solutions of contrast material (400 mgI/ml iomeprol). The four solutions were diluted as follows: 1/infinity, 1/200, 1/80, and 1/20. All scans were performed with the following parameters: slices/collimation 16/0.75 mm, rotation time 375 ms. Each specimen was scored for the presence of atherosclerotic plaques. In each plaque the attenuation was measured in four regions of interest for lumen, plaque (non-calcified thickening of the vessel wall), calcium, and surrounding (oil surrounding the vessel). The results were compared with a one-way analysis of variance test and were correlated with Pearson's test. There were no significant differences in the attenuation of calcium and oil in the four solutions. The mean attenuation in the four solutions for lumen (35+/-10, 91+/-7, 246+/-18, 511+/-89 HU) and plaque (22+/-22, 50+/-26, 107+/-36, 152+/-67 HU) was significantly different between each decreasing dilution (p<0.001). The mean attenuation of lumen and plaque of coronary plaques showed high correlation, while the values were significantly different (r=0.73; p<0.001). Intracoronary attenuation modifies significantly the attenuation of plaques assessed with MSCT.

Cadaver↗

Benign focal liver lesions: spectrum of findings on SonoVue-enhanced pulse-inversion ultrasonography.

The prevalence of benign focal liver lesions (BFLL) is high both in the general population and in patients with known malignancies. The gray-scale ultrasound (US) technique is usually the first-line imaging modality used in the radiological workup of such lesions, but unfortunately it lacks specificity. Furthermore, Doppler examination may often be unsatisfactory owing to motion artefacts, or when small or deeply located lesions are evaluated. Recently, microbubble-based contrast agents used in combination with gray-scale US techniques, which are very sensitive to nonlinear behavior of microbubbles, have led to a better depiction of both microvasculature and macrovasculature of focal hepatic masses, thus improving the reliability of using US in the assessment of liver tumors. This review illustrates the spectrum of enhancement patterns of BFLL on contrast-enhanced ultrasonography with SonoVue, a second-generation microbubble-based contrast agent.

Adenoma, Liver Cell↗

Image assessment with multislice CT coronary angiography.

AIM: To investigate the diagnostic accuracy of two different protocols for image evaluation used in multislice computed tomography coronary angiography (MSCT-CA). MATERIALS AND METHODS: Sixty patients with suspected coronary artery disease undergoing conventional coronary angiography (CA) were enrolled for MSCT-CA. All patients underwent 16-row MSCT (Sensation 16, Siemens, Germany) with the following parameters: detector rows 16, collimation 0.75 mm, gantry rotation time 375 ms. Two independent observers assessed the images for significant stenosis using a a protocol with standard projections and a three-dimensional protocol. The diagnostic accuracy for both methods was calculated using quantitative CA as a reference standard. RESULTS: The sensitivity, specificity, negative predictive value and positive predictive value obtained with the conventional projection protocol and with three-dimensional protocol were: 54% and 93%, 97% and 97%, 76% and 86%, 92% and 99%, respectively. CONCLUSIONS: Conventional projections in the assessment of MSCT-CA provide insufficient diagnostic accuracy compared with three-dimensional processing.

Contrast Media↗

Technical analysis of volume-rendering algorithms: application in low-contrast structures using liver vascularisation as a model.

AIM: To assess the influence of pre-set volume-rendering opacity curves (OC) on image quality and to identify which absolute parameters (density of aorta, hepatic parenchyma and portal vein) affect visualization of portal vascular structures (low-contrast structures). MATERIALS AND METHODS: Twenty-two patients underwent a dual-phase spiral CT with the following parameters: collimation 3 mm, pitch 2, increment 1 mm. Three scans were performed: one without contrast medium and the latter two after the injection of contrast material (conventionally identified as ''arterial'' and ''portal''). The images were sent to a workstation running on an NT platform equipped with post-processing software allowing three-dimensional (3D) reconstructions to generate volume-rendered images of the vascular supply to the liver. Correlation between the absolute values of aorta, liver and portal vein density, OC parameters, and image quality were assessed. RESULTS: 3D images generated using pre-set OC obtained a much lower overall quality score than those produced with OC set by the operator. High contrast between the liver and the portal vein, for example during the portal vascular phase, allows wider windows, thus improving image quality. Conversely, the OC in the parenchymal phase scans must have a high gradient in order to better differentiate between the vascular structures and the surrounding hepatic parenchyma. CONCLUSIONS: Image features considered to be of interest by the operator cannot be simplified by the mean of pre-set OC. Due to their strong individual variability automatic 3D algorithms cannot be universally applied: they should be adapted to both image and patient characteristics.

Aged↗

Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of coronary angiography.

PURPOSE: To assess the variability in attenuation of coronary plaques with multislice CT-angiography (MSCT-CA) in an ex-vivo model with varying convolution kernels. MATERIALS AND METHODS: MSCT-CA (Sensation 16, Siemens) was performed in three ex-vivo left coronary arteries after instillation of contrast material solution (Iomeprol 400 mgI/ml, dilution: 1/80). The specimens were placed in oil to simulate epicardial fat. Scan parameters: slices 16/0.75 mm, rotation time 375 ms, feed/rotation 3.0 mm, mAs 500, slice thickness 1 mm, and FOV 50 mm. Datasets were reconstructed using 4 different kernels (B30f-smooth, B36f-medium smooth, B46f-medium, and B60f-sharp). Each scan was scored for the presence of plaques. Once a plaque was detected, the operator performed attenuation measurements (HU) in coronary lumen, oil, calcified and soft plaque tissue using the same settings in all datasets. The results were compared with T-test and correlated with Pearson's test. RESULTS: Overall, 464 measurements were performed. Significant differences (p<0.05) were found for the mean attenuation of lumen (B30f/B36f, B30f/B60f, B36f/B46f, B36f/B60f, and B46f/B60f), oil (B30f/B36f, B30f/B46f, B30f/B60f, B36f/B46f, and B46f/B60f), calcium (all kernels), and plaque (B30f/B36f, B30f/B46f, B30f/B60f, and B46f/B60f) using 4 different kernels. The attenuation values (mean+/-SD) within the lumen (246+/-6, 215+/-13, 248+/-5, and 270+/-7), oil (-123+/-3, -127+/-1, -121+/-6, and -127+/-4), calcified plaque tissue (703+/-334, 739+/-364, 817+/-381, and 1181+/-503), and soft plaque tissue (134+/-56, 111+/-49, 120+/-56, and 102+/-41) showed high correlation (p<0.001) when attenuation of all structures were compared in different kernels. CONCLUSIONS: Use of sharper convolution kernels significantly increases the attenuation of the calcium within coronary plaques and reduces the attenuation of soft plaque tissue.

Aged↗

Liver haemangiomas undetermined at grey-scale ultrasound: contrast-enhancement patterns with SonoVue and pulse-inversion US.

The objective of this study was to describe the spectrum of contrast-enhancement patterns of hepatic haemangiomas undetermined at grey-scale ultrasound (US) on SonoVue-enhanced pulse-inversion (PI) US. Twenty patients (11 women, nine men) with 35 haemangiomas (size range: 1-7 cm; mean: 3.1 cm) undetermined at baseline US underwent PI at low M.I. (0.05-0.08) after i.v. injection of SonoVue. All haemangiomas were confirmed by typical helical computed tomography (CT) and/or magnetic resonance imaging (MRI) findings. US examinations were videotaped and then reviewed by two experienced radiologists blinded to the final diagnosis. Readers evaluated by consensus the baseline echogenicity and the dynamic enhancement pattern of each lesion, in comparison with adjacent liver parenchyma. After administration of SonoVue, 31/35 (88%) haemangiomas showed peripheral hyperechoic nodules in the arterial phase, followed by progressive centripetal fill-in, which was complete in 25/35 cases and incomplete in 6/35 cases. Three out of 35 (9%) haemangiomas showed rapid and complete fill-in in the arterial phase, which persisted in the portal and delayed phases. Finally, 1/35 haemangiomas (3%) showed a rim of arterial contrast enhancement with progressive and complete centripetal fill-in in portal-venous and delayed phases. In conclusion, PI after the administration of SonoVue enabled the depiction of typical contrast-enhancement patterns in haemangiomas undetermined at baseline US.

Adult↗

Diagnostic work-up of arrhythmogenic right ventricular cardiomyopathy by cardiovascular magnetic resonance.

Cardiovascular magnetic resonance (CMR) has become a widespread diagnostic tool. Since its introduction, CMR has been used to image patients with a known or suspected arrhythmogenic right ventricular cardiomyopathy (ARVC). Several abnormalities have been found and described by CMR and at present this diagnostic tool is considered very important for the diagnosis. However, the diagnosis of ARVC relies upon the fulfillment of both clinical and functional criteria and CMR can provide several but not all the information useful for the diagnosis. Furthermore, some findings such as evidence of right ventricular epicardial fat, once considered a peculiar marker of ARVC, have been shown to possess a low specificity. This document was prepared by representatives of the three Italian official Organizations involved in CMR. Its main scope is to highlight the problems encountered when studying patients with suspected ARVC at CMR, to indicate the basic technical equipment needed, to recommend a proper imaging protocol and to offer a consensus on the main features relevant for the diagnosis.

Arrhythmogenic Right Ventricular Dysplasia↗

Acute traumatic acromioclavicular joint lesions: role of ultrasound versus conventional radiography.

PURPOSE: To assess the diagnostic potential of ultrasound as compared to conventional radiography in quantifying the anatomic and structural damage and determining the grade of acute traumatic lesions of the acromioclavicular (AC) joint. MATERIALS AND METHODS: From September 2001 to September 2002, 18 patients (16 men, 2 women; age range: 17-78 years) who came to our Emergency Service with clinically suspected acute traumatic AC joint lesion were examined by ultrasonography with a variable frequency linear-array transducer (7.5-12 Mhz). The morphology of the AC joint peri-articular ligaments and soft tissues, distance between the edge of the acromion and the lateral margin of the clavicle, distance between the superior edge of the coracoid and the inferior margin of the clavicle were evaluated. Conventional radiography was performed prior to ultrasound using routine antero-posterior (A-P), single-film stress and "outlet" projections. All patients subsequently underwent clinical follow-up for a mean period of six months. RESULTS: On US examination, all patients presented AC ligament lesion associated with consistent intra- and extra-articular sero-haemorrhagic effusion. Six of the 18 patients had suffered indirect trauma. Diastasis of the AC joint with ligament lesion not associated with involvement of coracoclavicular (CC) joint and with ligament integrity was observed. Twelve of the 18 patients had direct trauma. Changes to AC and CC ligaments with consequent diastasis of both joints were observed. Measurements of AC and CC distance obtained on US examination corresponded to those obtained at conventional radiography in the A-P projection. At clinical follow-up, no variation in the previously established diagnosis was recorded in any patient. CONCLUSIONS: If appropriate methodology and adequate transducers are used, ultrasound is an accurate and reliable technique for the evaluation of acute AC joint injuries, complementing and correlating well with conventional radiography.

Acromioclavicular Joint↗

Focal nodular hyperplasia in normal and fatty liver: a qualitative and quantitative evaluation with contrast-enhanced ultrasound.

The aim of this study was to describe gray-scale appearance of liver parenchyma and focal nodular hyperplasia (FNH) by pulse inversion (PI) ultrasound (US) at baseline and after contrast agent administration in patients with normal and fatty liver. Sixteen consecutive patients (12 women, 4 men) with 29 previously diagnosed FNHs (15 of 29 located in normal liver and 14 of 29 in fatty liver) underwent PI US before and after SH U 508A (Levovist) injection. Signal intensity values were measured within the FNHs and the adjacent liver parenchyma in selected images. Baseline echogenicity of fatty liver was higher (15.19 +/- 2.90 dB +/- SD) than normal liver (10.91 +/- 3.15 dB +/- SD; p<0.001). After Levovist administration, normal livers (7 of 16) showed a statistically significant increase of echogenicity (16.59 +/- 3.81 dB +/- SD; p<0.001) in comparison with fatty livers (9 of 16; 15.75 +/- 3.12 dB +/- SD). The FNHs located in normal liver showed baseline echogenicity higher (12.29 +/- 3.22 dB +/- SD) than that of FNHs arising in fatty liver (7.06 +/- 2.43 dB +/- SD; p<0.001). After Levovist administration, FNHs located in normal liver showed a statistically significant increase of echogenicity (25.30 +/- 4.62 dB +/- SD) in comparison with FNHs located in fatty liver (13.58 +/- 3.54 dB +/- SD; p<0.001); the latter always showed mean values of echogenicity lower than surrounding liver parenchyma. In our series decreased contrast-enhancement pattern of both fatty liver and FNHs located in fatty liver was the most prominent finding when Levovist is administered. Contrast washout was a distinctive feature of FNH arising from the fatty liver.

Adult↗