PubMed Health⌕ Search

Biomedical subjects

Massimo Porqueddu

Publications and source records attributed to Massimo Porqueddu.

7 recordsLinked to original sources

Head-to-head comparison of two- and three-dimensional transthoracic and transesophageal echocardiography in the localization of mitral valve prolapse.

OBJECTIVES: The aim of this study, undertaken in patients who underwent mitral valve (MV) repair surgery, was to evaluate the feasibility and accuracy of 3-dimensional (3D) transthoracic (TTE) and transesophageal (TEE) echocardiography in the evaluation of MV pathology. BACKGROUND: A pre-operative assessment of MV anatomy is essential to surgical design in patients undergoing MV repair. Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy, 3D TTE and 3D TEE could increase the understanding of MV apparatus and individual scallop identification. METHODS: One-hundred-twelve consecutive patients with severe mitral regurgitation due to MV prolapse underwent a complete 2D and 3D TTE the day before surgery and a complete 2D and 3D TEE in the operating room. Echocardiographic data obtained by the different techniques were compared with surgical inspection. RESULTS: Three-dimensional techniques were feasible in a relatively short time (3D TTE: 7 +/- 4 min; 3D TEE: 8 +/- 3 min), with good (3D TTE 55%; 3D TEE 35%) and optimal (3D TTE 21%; 3D TEE 45%) imaging quality in the majority of cases. Three-dimensional TEE allowed more accurate identification (95.6% accuracy) of all MV lesions in comparison with other techniques. Three-dimensional TTE and 2D TEE had similar accuracies (90% and 87%, respectively), whereas the accuracy of 2D TTE (77%) was significantly lower. CONCLUSIONS: Three-dimensional TTE and TEE are feasible and useful methods in identifying the location of MV prolapse. They were superior in the description of pathology in comparison with the corresponding 2D techniques and should be regarded as an important adjunct to standard 2D examinations in decisions regarding MV repair.

Aged↗

Left common carotid artery as inflow site in coronary artery bypass grafting.

Porcelain aorta is associated to significantly increased risk of atheromatous embolization in patients who undergo cardiac surgery. We described three cases in which coronary artery bypass grafting was performed off-pump and the saphenous vein graft was anastomosed proximally to the left common carotid artery. This technique permitted avoidance of ascending aortic manipulation and reduce the risk of atheromatous embolization.

Aged↗

[Off-pump coronary bypass surgery: pros and cons].

Off-pump coronary artery bypass surgery is a well established surgical option for patients candidate to coronary artery bypass. Current evidence suggests that there are no differences between off-pump and on-pump coronary surgery in terms of major perioperative outcomes such as perioperative mortality, myocardial infarction, stroke, and renal failure, whereas off-pump coronary surgery seems to reduce some minor complications like atrial fibrillation, transfusion requirements, and postoperative hospital stay. However, some recent papers suggest that graft patency may be lower for grafts performed with the off-pump technique. In this paper we review current knowledge about pros and cons of off-pump and on-pump coronary bypass surgery.

Atrial Fibrillation↗

Long-term results after aortic valve replacement with the Bravo 400 stentless xenograft.

BACKGROUND: This study was undertaken to evaluate the long-term clinical and echocardiographic outcome after aortic valve replacement with the Bravo Cardiovascular Model 400 stentless xenograft. METHODS: Between February 1992 and January 1994, 67 patients underwent aortic valve replacement with the Bravo 400 bioprosthesis. The valvular pathology was aortic stenosis in 36 patients (53.7%), aortic insufficiency in 17 patients (25.4%), and mixed lesion in 14 patients (20.9%). Mean follow-up time was 9.8 +/- 2.73 years and median follow-up time was 11 years. Cumulative follow-up time was 659 patients-years and was 94% complete. RESULTS: No early deaths were observed. Overall survival estimates at 11 years were 74.71% +/- 5.47%. The actuarial freedom from valve-related death at 11 years was 91.04% +/- 3.84%; from cardiac-related death at 11 years it was 87.95% +/- 4.29%; and from noncardiac death at 11 years it was 85.14% +/- 4.58%. Eleven-year Kaplan-Meier survival of patients younger than 65 years was 90.91% +/- 6.13% versus 66.08% +/- 7.38% for older patients (p = 0.0307, log-rank test). The actuarial freedom from all valve-related morbidity and mortality at 11 years was 80.3% +/- 5.4%. The mean transvalvular gradient decreased significantly after aortic valve replacement with a corresponding increase in effective orifice area. Left ventricular mass index at 10-year follow-up was 68.5% of the preoperative value. CONCLUSIONS: The Bravo Cardiovascular Model 400 stentless xenograft has provided good clinical and hemodynamic results up until 11 years of follow-up.

Adult↗

Six-year monitoring of the donor-specific immune response to cryopreserved aortic allograft valves: implications with valve dysfunction.

BACKGROUND: The immune rejection has been anticipated as one of the major causes of allograft aortic valve (AAV) degeneration. The purpose of this study was to prospectively serially measure the magnitude and evolution of the recipient anti-HLA class I antibody response up to 6 years from AAV implant and to correlate serologic data with valve performance by means of a concurrent echocardiographic survey. METHODS: Cryopreserved AAVs were obtained from multiorgan HLA-typed donors. Nineteen patients younger than 50 years (mean age, 43.3 +/- 8 years) were prospectively studied. After successful surgery, all AAV recipient underwent at 3 and 6 months and each year postoperatively (mean follow-up, 71.9 months) concomitant serum sample collection and two-dimensional transthoracic echocardiography. The presence of anti-HLA antibodies was tested against a panel of lymphocytes obtained from 30 blood donors. RESULTS: Progressive structural valve deterioration was seen in 6 patients (31.5%) of whom 4 (21%) were reoperated. All pretransplant recipients sera were panel-reactive antibody negative. Seventeen patients (89.4%) demonstrated significant panel-reactive antibody levels, which peaked at 6 months postoperatively, declined from 6 to 24 months, and slowly decreased afterward. In 14 of 19 cases (73.6%) donor-specific HLA antibodies were identified. A strong immunization (6-year persistence of panel-reactive antibody > 70% and peak panel-reactive antibody > 80%) was detected in 31.5% and 36.8% of recipients, respectively. Strong immunization was found to be significantly associated with progressive structural deterioration. CONCLUSIONS: The immune reaction after cryopreserved AAV implantation is a peculiar long-lasting response occurring in the majority of recipients younger than 50 years of age. An association between a sustained and pronounced immunization and an aggressive AAV degeneration was observed.

Adolescent↗

Biological effects of off-pump vs. on-pump coronary artery surgery: focus on inflammation, hemostasis and oxidative stress.

Cardiopulmonary bypass (CPB) has been recognized as a cause of complex systemic inflammatory response, which significantly contributes to several adverse postoperative complications. In the last few years, off-pump coronary artery bypass grafting has gained widespread diffusion as an alternative technique to conventional on-pump coronary artery bypass grafting. Surgeons supporting off-pump surgery state that the avoidance of the CPB and myocardial ischemia-reperfusion significantly reduces the postoperative systemic inflammatory response and other biological derangements and, possibly, may improve the clinical outcomes. We review, here, the available evidence concerning possible differences between off-pump and on-pump procedures in terms of inflammation, hemostasis and oxidative stress. Consistent differences in the involvement of these systems are observed, but they are limited to the final steps of the surgical procedures and the early hours after. These findings suggest that the global surgical trauma may be as important, or even more, as the CPB in terms of systemic inflammatory and coagulation-fibrinolytic pathway activation. Further studies are needed in order to confirm this hypothesis.

Biomarkers↗

Lack of association between serum immunoreactivity and Chlamydia pneumoniae detection in the human aortic wall.

BACKGROUND: Only a few studies have focused the attention on the relation between elevated anti-Chlamydia pneumoniae (CP) antibodies and the detection of CP in the arterial wall. The aim of our study is thus to investigate the relationship between immune response to CP and detection of CP in the aortic walls of patients with abdominal aortic aneurysm. METHODS AND RESULTS: A specimen of aortic wall was obtained from 102 consecutive patients who underwent abdominal aneurysm repair. The possible presence of CP was studied by polymerase chain reaction and confirmed by nonradioactive DNA hybridization. Antibody response to CP was studied (IgG, IgA titers). We found 33 patients (32.4%) with CP DNA+. No correlation between CP DNA detection and antibody titers was found (IgG P=0.52, IgA P=0.66). High correlation between IgG and IgA titer was observed (P<0.01). Endovascular presence of CP and antibody titers was not related to the age of the patient. CONCLUSIONS: CP antibody titers are not associated with the presence of CP in the aortic wall of patients with abdominal aortic aneurysm.

Antibodies, Bacterial↗