PubMed Health⌕ Search

Biomedical subjects

Masumitsu Hatta

Publications and source records attributed to Masumitsu Hatta.

3 recordsLinked to original sources

Evaluation of the BD Phoenix SMIC/ID, a new streptococci identification and antimicrobial susceptibility panel, for potential routine use in a university-based clinical microbiology laboratory.

We evaluated the new BD Phoenix automated microbiology system (Becton Dickinson Diagnostic Systems, Sparks, MD) SMIC/ID-4 panel for routine identification (ID) and antimicrobial susceptibility testing (AST) of streptococci in a university-based laboratory. Clinical isolates of Streptococcus pneumoniae (n = 92), Streptococcus pyogenes (n = 24), and Streptococcus agalactiae (n = 10) were collected, and comparisons were made with the routine manual methods used in our microbiology laboratory for ID and susceptibility testing. ID concordance with manual methods was 85.9%, 95.8%, and 90.0% for S. pneumoniae, S. pyogenes, and S. agalactiae, respectively. With respect to AST concordance for S. pneumoniae and beta-hemolytic streptococci (S. pyogenes and S. agalactiae) using Phoenix and standard broth microdilution panels, overall essential agreement was 93.0% and 97.5%, respectively, whereas overall category agreement was 92.4% and 98.9%, respectively. Major and minor error rates for S. pneumoniae and beta-hemolytic streptococci were 0.5% and 0.3%, and 7.1% and 0.8%, respectively. Very major errors were not observed in this study. Mean time for ID and AST test completion was 13.6 +/- 1.6, 10.7 +/- 2.4, and 11.2 +/- 2.3 h for S. pneumoniae, S. pyogenes, and S. agalactiae, respectively. We have demonstrated that Phoenix ID results show high agreement with manual ID and that AST performance was equivalent to standard broth microdilution in less time.

Anti-Bacterial Agents↗

Validation of low-temperature steam with formaldehyde sterilization for endoscopes, using validation device.

BACKGROUND: Validation of sterilization is an important step before clinical use of medical equipment. Adequate validation of sterilization of the endoscope has not been reported. One reason for this is the lack of suitable devices for validation. METHODS: The VDES (validation device for endoscope sterilization; Olympus prototype model, Olympus, Tokyo, Japan) was designed in two types (type A and type B) and resembles gastroscopes and duodenoscopes, respectively. Each type consists of inner and outer tubing and a central capsule containing a biological indicator. The device was designed to examine the effectiveness of low-temperature sterilizers, such as ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam with formaldehyde (LTSF) sterilizer. The aim of this study was to validate the sterilization of GI endoscopes by the LTSF sterilizer. Sterilization was assessed using both types of VDES after a 60-min application of LTSF. RESULTS: Culture of the biological indicator confirmed the complete eradication of the bacteria in a total of 10 experiments with each type of VDES after LTSF sterilization. CONCLUSIONS: Our results confirm that the LTSF sterilizer may sterilize endoscopes currently distributed by Olympus. Commercialization of VDES will make it possible to evaluate the reliability of sterilization when it is set in the sterilization device with endoscopes.

Bacillaceae↗

[Roles of Department of Clinical Laboratory in infection control].

The Department of Clinical Laboratory plays an important role in the hospital and has much information about patients and pathogens. Laboratory data are essential to support clinical physicians who diagnose and treat patients. For nosocomial infections, laboratory-based surveillance is recognized as essential to confirm outbreaks. Therefore, the role of the Department of Clinical Laboratory is very important in infection control. In Tohoku University Hospital, we have an Infection Control Unit located in the Department of Clinical Laboratory. The core role of the Infection Control Unit is diagnosis, treatment and preventative healthcare associated with infections. The Infection Control Team (ICT) performs rounds in the hospital (The ICT members are ICN, ICD, a microbiological technologist and a dietician), consultations about clinical cases, infection control, and organize the regional infection control network, "Miyagi Infection Control Network". The ICT rounds are performed once a week in two wards, and two times a year for one ward. The consultations are an important role of the ICD, and concern clinical infection cases and infection control in our hospital and the other regional hospitals, and produce advice on appropriate clinical information. The regional network is important for the collection of information about the pathogens and the susceptibility of antimicrobial agents in the region. "Miyagi Infection Control Network" has held a forum 5 times a year from 1999, and 300-400 healthcare workers join the forum and discuss infection control.

Clinical Laboratory Information Systems↗