Mats Lundqvist

Publications and source records attributed to Mats Lundqvist.

6 recordsLinked to original sources

Single-shot dual-energy subtraction mammography with electronic spectrum splitting: feasibility.

We present a single-shot dual-energy subtraction mammography technique using an energy sensitive photon counting detector. An electronic threshold near the middle of the X-ray spectrum discriminates between high- and low-energy photons, and allows the simultaneous acquisition of high- and low-energy images which can be combined to suppress anatomical clutter. By setting the electronic threshold close to 33.2 keV (the k-edge of iodine) the system is optimized for dual-energy contrast-enhanced imaging of breast tumors. This method eliminates the need for separate exposures which might otherwise lead to motion artifacts. The method is illustrated in phantom images.

Artificial Intelligence↗

Scatter rejection in multislit digital mammography.

The scatter to primary ratio (SPR) was measured on a scanning multislit full-field digital mammography system for different thickness of breast equivalent material and different tube voltages. Scatter within the detector was measured separately and was found to be the major source of scatter in the assembly. Measured total SPRs below 6% are reported for breast range 3-7 cm. The performance of the multislit assembly is compared to other imaging geometries with different scatter rejection schemes by using the scatter detective quantum efficiency.

Artifacts↗

Remote imaging laser-induced breakdown spectroscopy and laser-induced fluorescence spectroscopy using nanosecond pulses from a mobile lidar system.

A mobile lidar system was used in remote imaging laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) experiments. Also, computer-controlled remote ablation of a chosen area was demonstrated, relevant to cleaning of cultural heritage items. Nanosecond frequency-tripled Nd:YAG laser pulses at 355 nm were employed in experiments with a stand-off distance of 60 meters using pulse energies of up to 170 mJ. By coaxial transmission and common folding of the transmission and reception optical paths using a large computer-controlled mirror, full elemental imaging capability was achieved on composite targets. Different spectral identification algorithms were compared in producing thematic data based on plasma or fluorescence light.

Journal Article↗

Remote imaging laser-induced breakdown spectroscopy and remote cultural heritage ablative cleaning.

We report, for what we believe to be the first time, on remote imaging laser-induced breakdown spectroscopy (LIBS). Measurements have been performed by using a tripled Nd:YAG laser working at 355 nm with 170 mJ pulse energy, with an expanded beam that is focused onto a target at 60 m distance. The LIBS signal is detected by using an on-axis Newtonian telescope and an optical multichannel analyzer. The imaging is performed by scanning the laser beam on the target. The same setup is also used in demonstrations of remote laser ablation for cleaning of contaminated objects with applications toward cultural heritage.

Journal Article↗

Generalized prism-array lenses for hard X-rays.

A Fresnel-like X-ray lens can be constructed by a triangular array of identical prisms whose base corresponds to the 2pi-shift length. Each column of prisms is progressively shifted from the optical axis by an arbitrary fraction of the prism height. Similarly to the multi-prism lens, quasi-parabolic profiles are formed by a superposition of straight-line segments. The resulting projected lens profile is approximately linear with a Fresnel-lens pattern superimposed on it to provide the focusing. This geometry exhibits a significantly larger effective aperture than conventional parabolic refractive lenses. Prototype lenses were fabricated by deep reactive ion etching of silicon. These one-dimensionally focusing lenses were tested at a synchrotron beamline and provided focal line-widths down to 1.4 microm FWHM and an intensity gain of 39 at a photon energy of 13.4 keV. Fabrication imperfections gave rise to unwanted interference effects resulting in several intensity maxima in the focal plane. The presented design allows the focal length to be shortened without decreasing the feature size of the lens. Furthermore, this feature size does not limit the resolution as for real Fresnel optics.

Journal Article↗

AEC for scanning digital mammography based on variation of scan velocity.

A theoretical evaluation of nonuniform x-ray field distributions in mammography was conducted. An automatic exposure control (AEC) is proposed for a scanning full field digital mammography system. It uses information from the leading part of the detector to vary the scan velocity dynamically, thus creating a nonuniform x-ray field in the scan direction. Nonuniform radiation fields were also created by numerically optimizing the scan velocity profile to each breast's transmission distribution, with constraints on velocity and acceleration. The goal of the proposed AEC is to produce constant pixel signal-to-noise ratio throughout the image. The target pixel SNR for each image could be set based on the breast thickness, breast composition, and the beam quality as to achieve the same contrast-to-noise ratio between images for structures of interest. The results are quantified in terms of reduction in entrance surface air kerma (ESAK) and scan time relative to a uniform x-ray field. The theoretical evaluation was performed on a set of 266 mammograms. The performance of the different methods to create nonuniform fields decreased with increased detector width, from 18% to 11% in terms of ESAK reduction and from 30% to 25% in terms of scan time reduction for the proposed AEC and detector widths from 10 to 60 mm. Some correlation was found between compressed breast thickness and the projected breast area onto the image field. This translated into an increase of the ESAK and decrease of the scan time reduction with breast thickness. Ideally a nonuniform field in two dimensions could reduce the entrance dose by 39% on average, whereas a field nonuniform in only the scanning dimension ideally yields a 20% reduction. A benefit with the proposed AEC is that the risk of underexposing the densest region of the breast can be virtually eliminated.

Breast↗