Hydroxyapatite-coated external fixation pins.

The aim of this review is to report on studies of hydroxyapatite-coated external fixation pins as a solution to enhance pin fixation. In a highly loaded animal study, three tapered pin types were compared: Type A uncoated, Type B coated with hydroxyapatite and Type C coated with titanium. There was a 13-fold increase in the extraction torque of Type B pins compared with Type A, and a twofold increase compared with Type C pins. Extraction torque was significantly lower compared with the corresponding insertion torque in both Types A (p < 0.001) and C (p = 0.003). Conversely, with the hydroxyapatite-coated pins there was no difference between extraction and insertion torque. In a clinical study of 76 external fixation pins in 19 patients treated with hemicallotasis for osteoarthritis on the medial side of the knee, pin insertion and extraction torque forces were measured. The patients were randomized to be treated with either standard tapered pins or tapered pins coated with hydroxyapatite. Extraction torque of the hydroxyapatite-coated pins was higher than the extraction torque of the standard pins in both cancellous and cortical bone (p < 0.005). In a prospective, randomized clinical study of osteoporotic wrist fractures, extraction torque of the coated pins was higher than with standard pins (p < 0.0001). These studies demonstrate that with the use of hydroxyapatite-coated pins, no deterioration of pin fixation occurs, and that there is no significant pin loosening and infection, regardless of bone type and loading conditions.

Animals↗

Effect of trabecular orientation on mechanical resistance and ultrasound propagation in specimens of equine vertebrae.

Osteoporosis involves alterations, not only in density, but also in the architectural organisation of the bone; in particular, trabecular orientation, following the skeletal load directions, lends a high degree of stiffness to the whole bone. We investigated the relationship between trabecular orientation, density, stiffness and ultrasound (US) propagation in two orthogonal directions (par. = parallel to, and ort. = orthogonal to the main orientation of the trabeculae) in cylindrical equine bone specimens (thoracic vertebrae) where a preferential orientation is present. A total of 15 cylinders were progressively decalcified with 0.2 mol/L ethylenediaminetetraacetic acid (EDTA). At different levels of decalcification, we measured the apparent density (g/cm(3)), bone mineral density or BMD (g/cm(2)), stiffness coefficient (MPa) and various US parameters. Before decalcification, stiffness values were the same in all directions. As the decalcification proceeded, the stiffness declined and, at low BMD values, it was significantly different in the two directions, being the highest in the par. one. Different behaviours of US parameters were observed in the two directions: SoS (speed of sound) was closely related to apparent density, BMD and stiffness in the par. direction (r = 0.88, 0.92 and 0.88, respectively, p < 0.0001). In the ort. direction, no significant association has been found between SoS and apparent density, BMD or stiffness. In the same experimental setup, US fast wave amplitude (FWA) was related to apparent density and BMD in the par. direction (r = 0.72 and 0.67, respectively, p < 0.0001) and in the ort. direction (r = 0.83 and r = 0.84 respectively, p < 0.0001). FWA was also correlated to stiffness in both directions (r = 0.61 par.; 0.81 ort., p < 0.0001). These results show that trabecular orientation strongly influences both mechanical properties of bone and US propagation. Furthermore, we found that US parameters can be predictors of mechanical properties of the bone independent of bone density.

Absorptiometry, Photon↗