PubMed Health⌕ Search

Biomedical subjects

Matthew A Barish

Publications and source records attributed to Matthew A Barish.

2 recordsLinked to original sources

Computerized tomographic colonography: performance evaluation in a retrospective multicenter setting.

BACKGROUND & AIMS: No multicenter study has been reported evaluating the performance and interobserver variability of computerized tomographic colonography. The aim of this study was to assess the accuracy of computerized tomographic colonography for detecting clinically important colorectal neoplasia (polyps >or=10 mm in diameter) in a multi-institutional study. METHODS: A retrospective study was developed from 341 patients who had computerized tomographic colonography and colonoscopy among 8 medical centers. Colonoscopy and pathology reports provided the standard. A random sample of 117 patients, stratified by criterion standard, was requested. Ninety-three patients were included (47% with polyps >or=10 mm; mean age, 62 years; 56% men; 84% white; 40% reported colorectal symptoms; 74% at increased risk for colorectal cancer). Eighteen radiologists blinded to the criterion standard interpreted computerized tomography colonography examinations, each using 2 of 3 different software display platforms. RESULTS: The average area under the receiver operating characteristic curve for identifying patients with at least 1 lesion >or=10 mm was 0.80 (95% lower confidence bound, 0.74). The average sensitivity and specificity were 75% (95% lower confidence bound, 68%) and 73% (95% lower confidence bound, 66%), respectively. Per-polyp sensitivity was 75%. A trend was observed for better performance with more observer experience. There was no difference in performance across software display platforms. CONCLUSIONS: Computerized tomographic colonography performance compared favorably with reported performance of fecal occult blood testing, flexible sigmoidoscopy, and barium enema. A prospective study evaluating the performance of computerized tomography colonography in a screening population is indicated.

Colonic Neoplasms↗

Multislice CT colonography: current status and limitations.

CT colonography (CTC) is a promising method for colorectal screening providing a full structural evaluation of the entire colon and gaining in popularity due to a superior safety profile, a low rate of complications, and high patient acceptance. Multislice CT (MSCT) has further improved the diagnostic potential of CTC by generating high-resolution CT images of the abdomen and pelvis in shorter acquisition times than was previously possible. Over the past year, multiple studies have been published on every aspect of CTC including techniques, image display, image reconstruction, and clinical trial results assessing the feasibility of CTC as a screening tool. Yet despite increasing clinical use, the appropriate role of CTC in colorectal cancer screening remains undefined and barriers to widespread adoption remain. In particular, though the test is generally regarded as easy to perform, accurate interpretation requires a steep learning curve. While several large studies have found high sensitivity and specificity, the accuracy of CTC in a screening population has yet to be verified and almost no health insurance plans reimburse for its use in colorectal screening. Ongoing research in computer-aided detection and new software tools, however, have the potential to increase accuracy and ease of interpretation significantly, accelerating its acceptance as a colorectal screening tool.

Colon↗