PubMed Health⌕ Search

Biomedical subjects

Matthew B Palmer

Publications and source records attributed to Matthew B Palmer.

4 recordsLinked to original sources

Comparison of three brachytherapy gynecological intercavitary treatment planning systems.

In preparation to change treatment planning systems for gynecological intracavitary insertion dosimetry, 3 patients were planned on 3 systems. The GE Target II, BrachyVision, and ADAC Pinnacle were the systems used. The dose distributions to several points of interest were calculated and compared. We analyzed the data sets to assess the differences and found that they were insignificant, mostly due to human error during digitization and calculation rounding.

Brachytherapy↗

Dosimetric consequences of using a surrogate urethra to estimate urethral dose after brachytherapy for prostate cancer.

PURPOSE: To assess the accuracy and dosimetric consequences of defining a surrogate urethra at the geometric center of the prostate in postimplant CT scans. METHODS AND MATERIALS: Eighty postimplant CT scans were obtained with a Foley catheter in place at Day 0 and at 1 month for 40 patients who had undergone (125)I prostate brachytherapy. The percentage of urethral volume receiving at least 275% of the prescribed dose (uV(275)), uV(250), uV(200), uV(150), maximal dose received by 90% of urethral volume (uD(90)), uD(70), uD(30), and uD(1) were measured for the Foley catheter and surrogate urethra. The distance between the Foley catheter and surrogate urethra was measured at the base, middle, and apex of the prostate. RESULTS: A statistically significant difference was found in all the above-listed dosimetric parameters between the Foley catheter and surrogate urethra at Day 0 (p <or= 0.001). At 1 month, the uD(90), uD(70), and uD(1) remained significantly different between the Foley catheter and surrogate urethra (p <or= 0.05). The difference in the uV(275) (p = 0.055) and uV(150) (p = 0.059) between the Foley catheter and surrogate urethra showed a trend toward statistical significance at 1 month. The uV(250), uV(200), and uD(30) were greater for the surrogate urethra than for the Foley catheter at 1 month, but were not significantly different statistically. The mean distance between the Foley catheter and the surrogate urethra was greatest at the base (1.2 cm) in the vertical axis at Day 0 and decreased substantially to 0.87 cm at 1 month (p = 0.0004). CONCLUSION: Using a surrogate urethra at the geometric center of the prostate may significantly overestimate the urethral dose at Day 0 and certain dosimetric parameters at 1 month. An alternative position for a surrogate urethra accounting for the difference in the location of the Foley catheter near the base of the prostate at Day 0 and 1 month could be considered in future studies.

Brachytherapy↗

Is intraoperative nomogram-based overplanning of prostate implants necessary?

PURPOSE: Several investigators have described intraoperative planning of prostate implants based on a nomogram. The aim of this work was to investigate the adequacy of the nomogram in predicting the total activity necessary for optimal dosimetry. METHODS AND MATERIALS: Eighty CT-based postimplant treatment plans were performed for patients who underwent ultrasound guided I-125 permanent implants alone between April 2000 and March 2001. The cohort of 40 patients had early stage (T1-T2) prostatic carcinoma and pre-treatment prostate volumes of 19-50 cc. I-125 seeds (0.391 mCi/seed) were implanted to achieve a distribution of 75% of the activity peripherally and 25% centrally. The CT studies were obtained on the day of (CT1) and at 1 month (CT2) after implant. All patients were catheterized at CT1, and 28 patients were catheterized at CT2 to visualize the urethra. For each patient, the percentage difference (dA) between the total implanted and nomogram predicted activity for a known prostate volume was calculated. The V200 (volume receiving 200% of the prescribed dose), V150, V100, V90, D100 (maximum dose received by 100% of the volume), D90, and D80 were measured for the prostate at CT1 and CT2. For the urethra, V275, V250, V200, and V150 were evaluated, and V100 and V70 were evaluated for the rectum. The Pearson test was used to correlate the dosimetric parameters with dA. Linear regression was used to fit the correlation of the volume and dose parameters with dA. RESULTS: The median V100 at CT1 and CT2 was 91.8% and 94.2%, respectively. The Pearson test was significant for the prostate V100 and dA measured at CT1 (p = 0.005) but not at CT2 (p = 0.106). A similar correlation was found for the prostate D90 at CT1 (p = 0.002), but not at CT2 (p = 0.076). D100 (maximum dose received by 100% of volume) for prostate did not correlate with dA at CT1 (p = 0.094) and CT2 (p = 0.148). The volume of the prostate receiving higher doses (greater than 150% and 200% of the prescribed dose) correlated with dA. There were no significant correlations between V275, V250, V200, and V150 at CT1 and CT2 as a function of dA for the urethra. V100 and V70 for the rectum correlated significantly with dA; for V100, p = 0.041 at CT1 and p = 0.014 at CT2 and for V70, p = 0.041 at CT1 and p = 0.026 at CT2. A linear regression model fitted to the prostate data obtained from CT1 with the goal of achieving a V100 of 90% and D90 of 145 Gy suggests that no increase in the number of seeds may be warranted using intraoperative planning. The implants examined showed no concomitant increase of urethral doses with increase in activity relative to the nomogram, but showed an increase in the rectal doses for the same increase in activity. CONCLUSION: The doses evaluated at CT1 represent an underestimate, whereas those obtained at CT2 represent an overestimate of the actual delivered protracted permanent implant dose. Based on these results and consideration of the dynamic nature of the dose distribution, target coverage obtained with intraoperative planning using the nomogram predicted activity is consistent with published guidelines for a quality implant and critical structure doses are within tolerance.

Brachytherapy↗