PubMed Health⌕ Search

Biomedical subjects

Matthew S Munson

Publications and source records attributed to Matthew S Munson.

9 recordsLinked to original sources

Gradient elution moving boundary electrophoresis for high-throughput multiplexed microfluidic devices.

A novel method for performing electrophoretic separations is described-gradient elution moving boundary electrophoresis (GEMBE). The technique utilizes the electrophoretic migration of chemical species in combination with variable hydrodynamic bulk counterflow of the solution through a separation capillary or microfluidic channel. Continuous sample introduction is used, eliminating the need for a sample injection mechanism. Only analytes with an electrophoretic velocity greater than the counterflow velocity enter the separation channel. The counterflow velocity is varied over time so that each analyte is brought into the separation column at different times, allowing for high-resolution separations in very short channels. The new variable of bulk flow acceleration affords a new selectivity parameter to electrophoresis analogous to gradient elution compositions in chromatography. Because it does not require extra channels or access ports to form an injection zone and because separations can be performed in very short channels, GEMBE separations can be implemented in much smaller areas on a micro-fluidic chip as compared to conventional capillary electrophoresis. Demonstrations of GEMBE separations of small dye molecules, amino acids, DNA, and immunoassay products are presented. A low-cost, polymeric, eight-channel multiplexed microfluidic device was fabricated to demonstrate the reduced area requirements of GEMBE; the device was less than 1 in.2 in area and required only n + 1 fluidic access ports per n analyses (in this instance, nine ports for eight analyses). Parallel separations of fluorescein and carboxyfluorescein yielded less than 3% relative standard deviation (RSD) in interchannel migration times and less than 5% RSD in both peak and height measurements. The device was also used to generate a calibration curve for a homogeneous insulin immunoassay using each of the eight channels as a calibration point with less than 5% RSD at each point with replicate analyses.

Journal Article↗

Scanning temperature gradient focusing.

Temperature gradient focusing (TGF) is a recently developed technique for the simultaneous concentration and electrophoretic separation of ionic analytes in microfluidic channels. One drawback to TGF as it has previously been described is the limited peak capacity; only a small number of analyte peaks (approximately 2-3) can be simultaneously focused and separated. In this paper, we report on a variation of the TGF method whereby the bulk flow rate is varied over time so that a large number of analytes can be sequentially focused, moved past a fixed detection point, and flushed to waste. In addition to improved peak capacity, the detection limits of the scanning TGF method can be adjusted on-the-fly, as needed for different samples. Finally, scanning TGF provides a technique by which high-resolution, high-peak-capacity electrophoretic separations can be performed in simple, straight, and short microfluidic channels.

Journal Article↗

On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system.

This paper describes extending plug-based microfluidics to handling complex biological fluids such as blood, solving the problem of injecting additional reagents into plugs, and applying this system to measuring of clotting time in small volumes of whole blood and plasma. Plugs are droplets transported through microchannels by fluorocarbon fluids. A plug-based microfluidic system was developed to titrate an anticoagulant (argatroban) into blood samples and to measure the clotting time using the activated partial thromboplastin time (APTT) test. To carry out these experiments, the following techniques were developed for a plug-based system: (i) using Teflon AF coating on the microchannel wall to enable formation of plugs containing blood and transport of the solid fibrin clots within plugs, (ii) using a hydrophilic glass capillary to enable reliable merging of a reagent from an aqueous stream into plugs, (iii) using bright-field microscopy to detect the formation of a fibrin clot within plugs and using fluorescent microscopy to detect the production of thrombin using a fluorogenic substrate, and (iv) titration of argatroban (0-1.5 microg/mL) into plugs and measurement of the resulting APTTs at room temperature (23 degrees C) and physiological temperature (37 degrees C). APTT measurements were conducted with normal pooled plasma (platelet-poor plasma) and with donor's blood samples (both whole blood and platelet-rich plasma). APTT values and APTT ratios measured by the plug-based microfluidic device were compared to the results from a clinical laboratory at 37 degrees C. APTT obtained from the on-chip assay were about double those from the clinical laboratory but the APTT ratios from these two methods agreed well with each other.

Anticoagulants↗

Characterization of the local temperature in space and time around a developing Drosophila embryo in a microfluidic device.

This paper characterizes a microfluidic platform that differentially controls the temperature of each half of a living Drosophila melanogaster fruitfly embryo in space and time (E. M. Lucchetta, J. H. Lee, L. A. Fu, N. H. Patel and R. F. Ismagilov, Nature, 2005, 434, 1134-1138). This platform relies on laminar flow of two streams of liquid with different temperature, and on rapid prototyping in polydimethylsiloxane (PDMS). Here, we characterized fluid flow and heat transport in this platform both experimentally and by numerical simulation, and estimated the temperature distribution around and within the embryo by numerical simulation, to identify the conditions for creating a sharper temperature difference (temperature step) over the embryo. Embryos were removed from the device and immunostained histochemically for detection of Paired protein. Biochemical processes are sensitive to small differences in environmental temperature. The microfluidic platform characterized here could prove useful in understanding dynamics of biochemical networks as they respond to changes in temperature.

Algorithms↗

Quantitative temperature gradient focusing performed using background electrolytes at various pH values.

Temperature gradient focusing (TGF) has previously been shown to be a practical technique for simultaneous concentration and separation of a variety of samples. In this paper, we demonstrate that TGF can be conducted at a wide range of pH values. Techniques for first-order prediction of the suitability of a given BGE for focusing are discussed. Buffer suitability for TGF is assessed experimentally by simultaneously concentrating and separating a pair of fluorescent analytes. One analyte is held at constant concentration for use as an internal standard while the concentration of the other dye is varied. Peak area is shown to vary linearly with the input dye concentration. A high degree of resolution (R(s) >3) of fluorescein and carboxyfluorescein, as well as for two LysoSensor-based dyes, is also observed. Foucusing and separation by TGF was successfully conducted quantitatively in BGE solutions of pH from 3.0 to 10.5.

Buffers↗

Diffusion based analysis in a sheath flow microchannel: the sheath flow T-sensor.

This paper describes a microfluidic channel that allows for diffusion-based analysis of adsorbing species without passivation of the channel surfaces. The sheath flow configuration was used to measure the diffusion coefficient of fluorescently labeled species from their spatial distribution within the microchannel by analyzing the derivative of the intensity profile at the interface between two distinct core fluids. Measurements for both a small molecule (rhodamine B) and an intermediate-sized protein (wheat germ agglutinin) were made, demonstrating the utility of the sheath flow T-sensor.

Diffusion↗

Suppression of non-specific adsorption using sheath flow.

The use of a confining sheath fluid within a microfluidic channel in order prevent non-specific adsorption of analytes to the walls of microchannels is demonstrated. A sheath-flow channel fabricated using laser cutting of Mylar films is developed. Numerical simulations of convective and diffusive mass transport within the channel are presented. The device is characterized experimentally using epifluorescence microscopy. It is demonstrated that the device is capable of preventing the adsorption of Rhodamine B to the walls of the channel for a period that would allow for adsorption-free T-sensor measurements to be made within the core of the flow channel. Generalized scaling rules based on the diffusion coefficient, sheath thickness and affinity of the potential adsorbant for the surface material are discussed. The controlled adsorption of the protein bovine serum albumin (BSA) to a gold surface is also demonstrated using SPR microscopy.

Adsorption↗

Passive electrophoresis in microchannels using liquid junction potentials.

The formation of the liquid junction potential (LJP) is a well-studied phenomenon that occurs in the presence of ionic concentration gradients. Although the LJP has been well characterized, its impact has generally been overlooked in microfluidic applications. The characteristics of flow in microfluidic channels cause this phenomenon to be particularly important, both as a source of deviation from anticipated results and as a tool capable of being harnessed to perform useful tasks. It is demonstrated that LJPs formed in microchannels can induce appreciable electrophoretic transport of charged species without the use of electrodes or an external power supply. This process is demonstrated in an H-filter (an H-shaped microfluidic channel used to bring two fluids into contact allowing extraction of diffusing species from one stream to another) by generating junction potentials between two flowing streams containing different concentrations of strong electrolytes and observing the mass transport of the charged dye fluorescein between those streams. It is shown that the LJP can be controlled to either accelerate or decelerate mass transport across a fluid interface in the absence of an interposed membrane. A preliminary mathematical description of the phenomena is offered to support the hypothesis that the observed mass transport is a result of the LJP. Possible practical microfluidic applications of electrophoretic transport without electrodes are discussed.

Diffusion↗