Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes.

AIM: Aim of this study was to investigate the relationship between refractive changes in the eye and biometric changes of the human crystalline lens during accommodation. Furthermore, differences in these relationships between young, healthy emmetropic and myopic subjects were analyzed. METHODS: Mean relative change in anterior chamber depth (ACD), lens thickness (LT), anterior segment length (ASL = ACD + LT) and in objective refraction were simultaneously assessed during near-point-induced accommodation in 10 emmetropic and 10 myopic subjects. Via a beam splitter, measurements were performed simultaneously using partial coherence interferometry (PCI) and infrared (IR) photorefraction. RESULTS: On average, for each diopter of accommodation LT increased by 0.063 mm in emmetropic and by 0.072 mm in myopic eyes, and ACD decreased by 0.047 mm and 0.057 mm, respectively. Mean ASL, indicating the position of the posterior lens pole, increased by 0.009 mm in emmetropic and by 0.013 mm in myopic eyes. The correlation between refractive and biometric changes was found to be essentially linear in both subgroups. Differences in ACD between emmetropic and myopic eyes were statistically significant at an accommodative stimulus of -1 D (p<0.04) and -2 D (p<0.02). CONCLUSION: The biometric and refractive changes of the human lens are highly correlated and linear in function in both emmetropic and myopic eyes.

Accommodation, Ocular↗

Effect of systemic bevacizumab therapy on retinal pigment epithelial detachment.

BACKGROUND: To evaluate the effect of systemic bevacizumab (Avastin) therapy on pigment epithelial detachment (PED) secondary to age-related macular degeneration (AMD) and to identify prognostic factors for PED regression and improvement in best corrected visual acuity (BCVA). STUDY DESIGN: Prospective uncontrolled pilot study. METHODS: Nine patients (nine eyes) received three systemic bevacizumab treatments at 2 week intervals and were examined at baseline, weeks 1, 2, 4, 6 and month 3 by using optical coherence tomography (Stratus OC, Carl Zeiss Meditec, Dublin, California, USA). Changes in maximum PED height and greatest linear diameter (GLD) were planimetrically analysed by using Adobe Photoshop CS and correlated with retinal morphological changes and changes in BCVA. RESULTS: Systemic bevacizumab therapy was well tolerated. Mean maximum PED height decreased significantly by 21% as early as 1 week (-96 microm (SD 48.8), p<0.01). At 3 months follow-up, two PEDs resolved completely, mean maximum PED height decreased significantly by 39% (-179 microm (SD 178), p = 0.02) and mean PED GLD by 24% (-714 microm (SD 1010), p = 0.07). Mean BCVA improved significantly by week 2 (+8.7 letters (SD 5.7), p<0.01) and at 3 months with 12.7 letters (SD 6.4) (p<0.01). CONCLUSION: In the examined nine patients, systemic bevacizumab therapy showed evidence for an effect on PED secondary to neovascular AMD in terms of a decrease in lesion height and diameter. A high PED at baseline was found to be a negative predictive factor for visual outcome.

Angiogenesis Inhibitors↗

Effect of anterior capsule polishing on the posterior capsule opacification-inhibiting properties of a sharp-edged, 3-piece, silicone intraocular lens: three- and 5-year results of a randomized trial.

PURPOSE: To evaluate the long-term effects of anterior capsule polishing on regeneratory posterior capsule opacification (PCO), anterior capsule opacification (ACO), and fibrotic PCO with a silicone intraocular lens (IOL) with sharp optic edges. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This prospective bilateral randomized patient- and examiner-masked clinical trial comprised 130 eyes of 65 patients with bilateral age-related cataract. All eyes had implantation of a 3-piece silicone IOL with a truncated, sharp-edged optic (CeeOn Edge 911A, Advanced Medical Optics). In 1 eye, the anterior capsule was extensively polished using an aspiration curette after phacoemulsification and cortex aspiration. Regenerative PCO was quantified objectively, while ACO and fibrotic PCO were graded subjectively 1, 2, 3, and 5 years postoperatively. RESULTS: The mean ACO score was significantly lower in the eyes in which the anterior capsule had been polished (1 year, P<.02; 2 years, P<.03; 3 years, P<.01; 5 years, P<.01). The mean difference in regeneratory PCO and fibrotic PCO scores between the 2 groups was not statistically significant. CONCLUSIONS: Three years after cataract surgery, eyes in which the anterior capsule had been polished had significantly less ACO. However, polishing did not lower PCO intensity when a sharp-edged CeeOn 911A IOL was implanted in the bag. Although results indicate that anterior capsule polishing may enhance the development of regeneratory PCO, this trend did not reach statistical significance.

Cataract↗

Local corneal thickness changes after small-incision cataract surgery.

PURPOSE: To assess whether a temporal limbal-corneal incision approach for phacoemulsification cataract surgery induces a gradient in corneal thickening along the horizontal meridian. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: Corneal thickness in 21 eyes of 21 patients was measured preoperatively as well as 1 day, 1 week, and 1 and 3 months after phacoemulsification through a temporal limbal-corneal incision. Measurements were performed using partial coherence interferometry (PCI) with a commercial instrument, the ACMaster (Carl Zeiss Meditec, Jena). Measurements were taken along the horizontal meridian centrally along the visual axis at 1.5 mm, 3.0 mm, and 4.5 mm eccentricity. RESULTS: Preoperatively, there were slight nasal-temporal differences in corneal thickness at all eccentricities. The mean thickness was 522 microm +/- 34 (SD) at 1.5 mm nasally and 513 +/- 36 microm at 1.5 mm temporally (P<.01). On day 1, there was a significant mean increase in corneal thickness (38 +/- 43 microm) along all locations. The thickening was slightly more pronounced in the periphery than in the center, a difference not reaching statistical significance. At 1 week, corneal thickness returned almost to baseline at all locations except for 3.0 mm temporally, where it was slightly, but not significantly, thicker (mean 8 +/- 14 mum). At 1 month, corneal thickness at the 3.0 mm temporal location returned to baseline. CONCLUSIONS: A nasal-temporal difference in corneal thickness was found preoperatively in all patients. Phacoemulsification through a temporal limbal-corneal incision caused an increase in corneal thickness along the horizontal meridian 1 day after surgery. The prolonged corneal thickening at 3.0 mm eccentricity temporally could be a result of the proximity to the incision site.

Aged↗

Comparison of partial coherence interferometers: Acmaster versus laboratory prototype.

PURPOSE: To evaluate anterior segment biometry using the ACMaster (Carl Zeiss Meditec AG, Jena, Germany) in regard to precision of measurement and clinical performance compared to the original laboratory prototype of the partial coherence interferometry technique. METHODS: Ten phakic (20 eyes) and 27 pseudophakic (44 eyes) patients were included in this study. Anterior segment biometry of phakic and pseudophakic study eyes was performed using the ACMaster and the laboratory prototype of the partial coherence interferometry technique. The ACMaster is a commercially available device based on the partial coherence interferometry technique, which provides high precision anterior segment measurements in a quick and user-friendly fashion. Examination included measurement of central corneal thickness, anterior chamber depth, and lens thickness, the latter only in the phakic eyes. RESULTS: The consistency of anterior segment measurements performed with both units was excellent in phakic as well as in pseudophakic eyes. In pseudophakic eyes, the measurement of anterior chamber thickness and lens thickness with the ACMaster produced several (typical) measurement artifacts in some cases, which partially aggravated the identification of the A-scan peak representing the anterior intraocular lens surface. CONCLUSIONS: The ACMaster is a user-friendly device that enables axial anterior segment biometry using the partial coherence interferometry technique with a reproducibility similar to that of the original laboratory prototype.

Anterior Eye Segment↗