Altered autonomic cardiac control predicts restenosis after percutaneous coronary intervention.

BACKGROUND: Early and late restenosis in up to 30% remains a major problem for long-term success after percutaneous coronary intervention (PCI). Compared to bare metal stents, the use of drug-eluting stents reduces restenosis below 10%, but implant coasts have to be considered. In restenosis noninvasive testing lacks diagnostic power. We applied a new approach to identify patients with a high risk for restenosis after PCI by combining heart rate (HR) and blood pressure variability (BPV) analyses. METHODS: In 52 patients with clinical suspicion of restenosis and history of PCI, we investigated patterns of cardiovagal autonomic regulation prior to cardiac catheterization. The patients were separated in (i) patients with restenosis (CAD+R) and (ii) patients without restenosis (CAD-R), where restenosis is defined as a stenosis greater than 75% of luminal diameter in at least one main vessel. The following parameters/methods were evaluated: Canadian Cardiovascular Society grade (CCS-grade), vessel disease score (CAD-level), left ventricular ejection fraction (LVEF), heart rate variability (HRV), BPV, baroreflex sensitivity (BRS), as well as HR turbulence and blood pressure (BP) potentiation caused by premature ventricular complexes. RESULTS: Whereas age, LVEF, CAD-level, CCS-grade, and mean BP did not differ between CAD+R and CAD-R, significant differences were found in (i) BPV: diastolic LF/P, systolic, and diastolic UVLF, (ii) in BRS: slope of tachycardic sequences, and (iii) in extrasystolic parameters: heart rate turbulence onset (HRTO) and potentiation of systolic BP (SBPP). Standard HRV parameters did not show significant differences between the groups. Using the two parameters diastolic LF/P (threshold >0.2) and HRTO (threshold >0) restenosis were predicted in 83.4%. CONCLUSIONS: These results demonstrate that indicators of sympathetic activation or vagal depression identify restenosis in patients after PCI, thus opening a perspective for a new noninvasive monitoring.

Angioplasty, Balloon, Coronary↗

Multivariate and multidimensional analysis of cardiovascular oscillations in patients with heart failure.

Within 5 years of first diagnosis, nearly 60% of patients with heart failure (HF) suffer from cardiac death. Early diagnosis of HF and reliable risk prediction are still required. Therefore, the objective of this study was to develop a parameter set for enhanced risk stratification in HF patients. In 43 patients suffering from HF (NYHA class > or =II, ejection fraction <45%) and 10 healthy subjects (REF), heart rate and blood pressure variability (HRV and BPV), interactions between heart rate and blood pressure (joint symbolic dynamics, JSD) and blood pressure morphology (BPM) were analysed. BPV, BPM and JSD measures revealed high significance (p<0.0001) in discriminating REF and HF. A set of three parameters from BPV, JSD and BPM was developed for risk stratification (sensitivity 76.5%, specificity 84.2%, area under the receiver operating characteristic curve 81.4%) in patients with HF.

Biological Clocks↗

Low HRV entropy is strongly associated with myocardial infarction.

Heart rate variability (HRV) is a marker of autonomous activity in the heart. An important application of HRV measures is the stratification of mortality risk after myocardial infarction. Our hypothesis is that the information entropy of HRV, a non-linear approach, is a suitable measure for this assessment. As a first step, to evaluate the effect of myocardial infarction on the entropy, we compared the entropy to standard HRV parameters. The entropy was estimated by compressing the tachogram with Bzip2. For univariate comparison, statistical tests were used. Multivariate analysis was carried out using automatically generated decision trees. The classification rate and the simplicity of the decision trees were the two evaluation criteria. The findings support our hypothesis. The meanNN-normalized entropy is reduced in patients with myocardial infarction with very high significance. One entropy parameter alone exceeds the discrimination strength of multivariate standards-based trees.

Algorithms↗

Spatiotemporal correlation analyses: a new procedure for standardisation of DC magnetocardiograms.

There is a lack of standard methods for the analysis of magnetocardiograms (MCGs). MCG signals have a shape similar to the ECG (P wave, QRS complex, T wave). High-quality multichannel recordings can indicate even slight disturbances of de- and repolarisation. The purpose of our study was to apply a new approach in the analysis of signal-averaged DC-MCGs. DC-MCGs (31-channel) were recorded in 182 subjects: 110 patients after myocardial infarction and 72 controls. Spatiotemporal correlation analysis of the QRS complex and T wave patterns throughout the entire heart cycle was used to analyse homogeneity of de- and repolarisation. These plots were compared to standard ECG analyses (electrical axis, Q wave, ST deviation, T polarity and shape). Spatiotemporal correlation analyses seem to be applicable in assessing the course of electrical repolarisation with respect to homogeneity. MCG provided all diagnostic information contained in common ECG recordings at high significance levels. The ECG patterns were included in 5/8 of our parameters for electrical axis, 6/8 for Q-wave, 7/8 for ST deviation and 5/8 for T-polarity based on two time series of correlation coefficients. We conclude that our spatiotemporal correlation approach provides a new tool for standardised analysis of cardiac mapping data such as MCG.

Algorithms↗

Vortex shaped current sources in a physical torso phantom.

Recent studies reported differential information in human magnetocardiogram and in electrocardiogram. Vortex currents have been discussed as a possible source of this divergence. With the help of physical phantom experiments, we quantified the influence of active vortex currents on the strength of electric and magnetic signals, and we tested the ability of standard source localization algorithms to reconstruct vortex currents. The active vortex currents were modeled by a set of twelve single current dipoles arranged in a circle and mounted inside a phantom that resembles a human torso. Magnetic and electric data were recorded simultaneously while the dipoles were switched on stepwise one after the other. The magnetic signal strength increased continuously for an increasing number of dipoles switched on. The electric signal strength increased up to a semicircle and decreased thereafter. Source reconstruction with unconstrained focal source models performed well for a single dipole only (less than 3-mm localization error). Minimum norm source reconstruction yielded reasonable results only for a few of the dipole configurations. In conclusion active vortex currents might explain, at least in part, the difference between magnetically and electrically acquired data, but improved source models are required for their reconstruction.

Action Potentials↗

Iohexol contrast medium induces QT prolongation in amiodarone patients.

AIMS: Amiodarone is widely used in ventricular tachyarrhythmias and atrial fibrillation, known to prolong QT-intervals. Concurrent administration of drugs prolonging QT- time can induce life-threatening ventricular tachyarrhythmia. METHODS: QT-interval changes following use of Iohexol contrast-medium for coronarangiography were observed comparing 21 patients taking long-term amiodarone therapy with 21 controls not taking amiodarone or QT-prolonging drugs retrospectively. RESULTS: Concurrent use of Iohexol and amiodarone was associated with significant prolongation of QTc-interval (433, 95%CI: 419-448 ms vs. 480, 95%CI: 422-483 ms, P < 0.001) the day after coronarangiograpgy. 6/21 patients showed severe prolonged QTc-interval of >500 ms. CONCLUSION: Caution is advised until more is known about pro-arrhythmic effects of Iohexol.

Amiodarone↗