PubMed Health⌕ Search

Biomedical subjects

Matthias Otto

Publications and source records attributed to Matthias Otto.

9 recordsLinked to original sources

Mass spectrometric evidence for different complexes of peptides and proteins with arsenic(III), arsenic(V), copper(II), and zinc(II) species.

Trivalent and pentavalent arsenic were incubated with sulfur-containing amino acid, peptide and protein solutions both as organic compounds (phenylarsine oxide, phenylarsonic acid, dimethylarsinic acid, monomethylarsonic acid) and as inorganic compounds (arsenite, As(III), and arsenate, As(V)). After incubation of phenylarsine oxide solutions with cysteine and glutathione the mass spectra showed a covalent bond between arsenic and sulfur, which was stable at both acidic and neutral pH values. The mass spectra were dominated by monovalent ions at m/z 272 for cysteine samples and at m/z 458 for glutathione samples. Based on these masses the ionic structures could be ascribed to either fragment ions of the covalent arsenic-sulfur complexes or to other arsenic-bonding sites presumably at the amino group. Interestingly, under the same conditions no interactions of inorganic arsenite or arsenate could be measured. In the presence of added Cu(2+) ions all mass signals caused by a reaction of phenylarsine oxide with glutathione disappeared. In these mass spectra only the oxidised form of glutathione (GSSG) was found because of the redox activity of Cu(II). For the model protein lysozyme, no interactions with arsenic could be detected, whereas definite Cu- and Zn-lysozyme complexes with a stoichiometry of 1:1 and 2:1 for Zn(2+) ions and Cu(2+) ions, respectively, were observed. In contrast, for thioredoxin a bonding of As that depended on the concentration of the disulfide-reducing agent tris(2-carboxyethyl) phosphine was demonstrated. For three different phenylarsonic acids and for dimethylarsinic acid that all contain pentavalent arsenic, complexes with glutathione appeared in the mass spectra, which can be attributed to non-covalent interactions or to a covalent bond caused by an additive reaction. The optimisation of the experimental conditions necessary for the mass spectrometric analysis of the interactions of the arsenic species with peptides and proteins is described and the obtained mass spectra that provide information on the kinds of bonds are discussed.

Arsenic↗

Microscopic dynamics of thin hard rods.

We analyze the microscopic dynamics and transport properties of a gas of thin hard rods. Based on the collision rules for hard needles we derive a hydrodynamic equation that determines the coupled translational and rotational dynamics of a tagged thin rod in an ensemble of identical rods. Specifically, based on a pseudo-Liouville operator for binary collisions between rods, the Mori-Zwanzig projection formalism is used to derive a continued fraction representation for the correlation function of the tagged particle's density, specifying its position and orientation. Truncation of the continued fraction gives rise to a generalized Enskog equation, which can be compared to the phenomenological Perrin equation for anisotropic diffusion. Only for sufficiently large density do we observe anisotropic diffusion, as indicated by an anisotropic mean-square displacement, growing linearly with time. For lower densities, the Perrin equation is shown to be an insufficient hydrodynamic description for hard needles interacting via binary collisions. We compare our results to simulations and find excellent quantitative agreement for low densities and qualitative agreement for higher densities.

Journal Article↗

Dynamic studies on the mobility of trace elements in soil and sediment samples influenced by dumping of residues of the flood in the Mulde River region in 2002.

In the analysis of soil samples, batch sequential extraction procedures are traditionally used for the fractionation of trace elements to access their mobility and potential risk for the contamination of groundwater. In the present work a continuous-flow technique has been used that enables not only the fast and efficient leaching of trace elements but as well as time-resolved studies on the mobilization of arsenic and selected heavy metals in different forms to be made. Rotating coiled columns (RCC) earlier used mainly in countercurrent chromatography have been successfully applied to the dynamic leaching of heavy metals from soils contaminated by flooding sludge's. The sample was retained in a PTFE rotating column as the stationary phase whereas aqueous solutions were continuously pumped through. The contents of elements were determined by on-line coupling of RCC and inductively coupled plasma atomic emission spectrometry (ICP-AES). This enables real-time data on the leaching process to be obtained. Dynamic and traditional batch procedures were compared. It has been shown that the aqueous elution under centrifugal forced conditions is much more effective for the mobilization of heavy metals. Hence, the dynamic leaching is characterized by a substantially more intensive interaction between solid and water and is besides substantially more time-saving than the conventional batch procedure. The RCC procedure was also employed for preliminary leaching studies with a simulated "acid rain". In comparison with the water leaching, the mobilization of heavy metals and arsenic from soil samples with employment of simulated acid rain as eluent was less effective.

Chemistry Techniques, Analytical↗

Local equation of state and velocity distributions of a driven granular gas.

We present event-driven simulations of a granular gas of inelastic hard disks with incomplete normal restitution in two dimensions between vibrating walls (without gravity). We measure hydrodynamic quantities such as the stress tensor, density and temperature profiles, as well as velocity distributions. Relating the local pressure to the local temperature and local density, we construct a local constitutive equation. For strong inelasticities the local constitutive relation depends on global system parameters, like the volume fraction and the aspect ratio. For moderate inelasticities the constitutive relation is approximately independent of the system parameters and can hence be regarded as a local equation of state, even though the system is highly inhomogeneous with heterogeneous temperature and density profiles arising as a consequence of energy injection. With respect to local velocity distributions we find that they do not scale with the square root of the local granular temperature. Moreover the high-velocity tails are different for the distribution of the x and the y components of the velocity, and even depend on the position in the sample, the global volume fraction, and the coefficient of restitution.

Journal Article↗

Optimization of capillary coating by hydroxyethyl methacrylate for capillary zone electrophoresis of proteins.

This work describes further improvements of coating fused silica capillaries with 2-hydroxyethyl methacrylate (HEMA) by atom transfer radical polymerization (ATRP). First, endcapping with a sterically less bulky silanyl reagent reduces the electrosmotic flow (EOF) by 25% in addition to the 40% EOF reduction caused by HEMA coating compared to a bare fused silica capillary. An additional hydrolysis step was introduced into the preparation of HEMA coated capillaries and leads to better reproducible migration times. The influence of the solvent during ATRP and the resulting polymer coating was investigated by replacement of DMF with water or water-methanol mixtures. The quality of the optimized coating was characterized by protein separations at pH 3. HEMA coated capillaries reveal up to 746000 plates. The polyvinyl alcohol (PVA) coated capillary provides only half of this efficiency. A long-term test at pH 9 shows good stability of the HEMA coated capillaries in basic medium. Also the numbers of plates in this medium was about 30% higher than for separations with the PVA capillary. In addition, the phosphate buffer was replaced by a volatile ammonium acetate buffer for later use with mass spectrometry (MS).

Buffers↗

Systematic optimisation of high-performance liquid chromatographic separation by varying the temperature, gradient, and stationary phase.

Optimisation of the separation of a synthetic drug mixture by HPLC is performed by changing both continuous variables, i.e. mobile phase composition and temperature, and categorical variables, here the stationary phase. The retention of solutes is described on the basis of a general linear model in which the different columns are modelled by indicator variables. From the solute-specific retention models the global separation optimum is evaluated on the basis of multidimensional window diagrams using relative retentions of all peak pairs as the figure-of-merit.

Androstenes↗