PubMed Health⌕ Search

Biomedical subjects

Matthias Rainer

Publications and source records attributed to Matthias Rainer.

6 recordsLinked to original sources

A new analytical material-enhanced laser desorption ionization (MELDI) based approach for the determination of low-mass serum constituents using fullerene derivatives for selective enrichment.

60]fullerene derivatives (dioctadecyl methano[60]fullerene, [60]fullerenoacetic acid, and IDA-[60]fullerene) were prepared and subjected to a comprehensive characterization study including protein binding properties and capacity. These fullerene derivatives were successfully applied as material-enhanced laser desorption/ionization (MELDI) carrier materials. It is shown that diverse functionalities result in characteristic human serum peak patterns (m/z 2000-20 000) in terms of signal intensity as well as the number of detectable masses. In addition, the fullerene derivatives clearly provided differences in the low molecular weight mass region (m/z 1000-4000) after elution of the adsorbed serum constituents, and [60]fullerenoacetic acid was the most effective carrier material. Novel high-speed, monolithic, high-resolution capillary columns, prepared by thermally initiated copolymerization of methylstyrene (MSt) and 1,2-bis(p-vinylphenyl)ethane (BVPE) were employed for eluate separation and target spotting. Thus, serum compounds in the low-mass range were successfully fractionated and subjected to MALDI-MS/MS analysis. This contribution, hence, proposes a new "top-down" strategy for proteome research enabling protein profiling as well as biomarker identification in the low-mass range using selective enrichment, high-resolution separation, and offline MALDI-MS/MS evaluation.

Adsorption↗

Mass spectrometric identification of serum peptides employing derivatized poly(glycidyl methacrylate/divinyl benzene) particles and mu-HPLC.

Biomarkers play a key role in preclinical screening and diagnosis of a disease. Various support materials are utilized for this task, in combination with MALDI-TOF-MS. The way to effectively bind serum contents and their profiling is well-elaborated by the material-enhanced laser desorption ionization (MELDI) approach. In this particular work, focus is placed on the development of a strategy to identify low molecular weight serum peptides. Poly(GMA/DVB) is derivatized in a way to achieve an affinity termed as immobilized metal ion affinity chromatography (IMAC). Iminodiacetic acid (IDA) is used as a chelating ligand, whereas copper (Cu2+) acts as a metal ion for complexing peptides and proteins out of blood serum. Polymer binds the serum compounds over a broad mass range, which includes low mass peptides and high mass albumin (66 kDa). Bound contents are eluted from material by an acetonitrile/trifluoroacetic acid mixture, which proves the reversible nature of metal and amino acid linkage. Polystyrene/divinyl benzene (PS/DVB) monolithic capillary column is used for fractionation through RP-HPLC, prior to the target spotting. The tandem TOF fragment ion mass spectra of each fraction is acquired and used to search against the Swiss-Prot database, using the Mascot search engine for the identification of peptides.

Amino Acid Sequence↗

Material-enhanced laser desorption/ionization (MELDI)--a new protein profiling tool utilizing specific carrier materials for time of flight mass spectrometric analysis.

Over the past couple of years, proteomics pattern analysis has emerged as an effective method for the early diagnosis of diseases such as ovarian, breast, or prostate cancer, without identification of single biomarkers. MALDI-TOF MS, for example, offers a simple approach for fast and reliable protein profiling, especially by using carrier materials with various physical and chemical properties, in combination with a MALDI matrix. This approach is referred to as material-enhanced laser desorption/ionization (MELDI). In this paper, we report the development and application of derivatized carrier materials [cellulose, silica, poly(glycidyl methacrylate/divinylbenzene) (GMA/DVB) particles, and diamond powder] for fast and direct MALDI-TOF MS protein profiling. The applicability of MELDI for rapid protein profiling was evaluated with human serum samples. These carriers, having various hydrophobicities, resulted in characteristic mass fingerprints, even if all materials were derivatized with iminodiacetic acid (IDA) to yield an immobilized metal affinity chromatography (IMAC) functionality. Our study demonstrates that analyzing complex biological samples, such as human serum, by employing different MELDI carrier materials yielded type- and size-dependent performance variation.

Indicators and Reagents↗

Strong binding of bioactive BMP-2 to nanocrystalline diamond by physisorption.

Nano-crystalline diamond (NCD)-coated surfaces were efficiently functionalized with bone morphogenetic protein-2 (BMP-2) by means of physisorption. Due to their randomly oriented texture, NCD-coated surfaces appear to bind complex molecules firmly. Applying various highly sensitive analytical methods, the interaction was found extremely stable. The strength of the experimentally measured adherence between BMP-2 and NCD was further corroborated by theoretical calculations. Oxygen treatment rendered NCD hydrophilic by the appearance of surface oxygen containing groups. This particular NCD surface exhibited even higher binding energies towards BMP-2 than the hydrophobic surface, and this surface was also favoured by cultured cells. Most importantly in this context, bound BMP-2 was found fully active. When cultured on BMP-2-treated NCD, osteosarcoma cells strongly up-regulated alkaline phosphatase, a specific marker for osteogenic differentiation. Hence, this simple method will allow generating highly versatile surfaces with complex biomimetic coatings, essentials for novel medical devices and implants as well as for innovative scaffolds in tissue engineering.

Absorption↗

Ultra-fast mass fingerprinting by high-affinity capture of peptides and proteins on derivatized poly(glycidyl methacrylate/divinylbenzene) for the analysis of serum and cell lysates.

The development of support materials in mass fingerprinting is an important task required for diagnostic markers in conjunction with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The material-based approach, which we introduced as material-enhanced laser desorption/ionization (MELDI), focuses not only on different functionalities, but also emphasizes the morphology, i.e. porosity or particle size of the carrier material. As a result, it provides a quick and sensitive platform for effective binding of peptides and proteins out of different biofluids, e.g. serum, spinal fluid, urine or cell lysates, and to subsequently analyze them with MALDI-TOF MS. This approach includes a built-in desalting step for serum protein profiling and is sensitive enough to detect proteins and peptides down to 100 fmol/microL. Here we co-polymerized glycidyl methacrylate (GMA) with divinylbenzene (DVB) using thermal polymerization to yield a GMA/DVB polymer for further modifications. Different affinities have been created, such as immobilized metal ion affinity (IDA-Cu2+), reversed-phase (RP) and anion-exchanger (AX) chromatography. The diverse derivatizations and the dispersity of the particles created by different chemical synthetic approaches were confirmed by characteristic infrared (IR) peaks. The polymerization carried out by non-stirring yielded an average pore radius of 6.1 microm (macro-pores) that enhanced the binding capacity enormously by offering enlarged surface areas. Moreover, atomic absorption spectrometry (AAS) provided the metal content loaded on iminodiacetic acid (IDA) in the case of poly(GMA/DVB)-IDA-Cu2+. To summarize, the optimized MELDI approach is sensitive in its performance, extremely fast and can be adapted to robotic systems for routine analysis, allowing sample preparation in less than 5 min in contrast to the conventional surface-enhanced laser desorption/ionization (SELDI) methods.

Blood Proteins↗

Derivatized cellulose combined with MALDI-TOF MS: a new tool for serum protein profiling.

Providing a rapid and sensitive protein profiling method for biomarker discovery from a variety of biological samples is crucial for the introduction of new markers that improve cancer patient diagnosis at early tumor stages, thus increasing the chances of curative treatment. We report here the development and application of derivatized cellulose particles for selective serum protein profiling. For immobilized metal ion affinity chromatography (IMAC), cellulose was derivatized with glycidyl methacrylate (GMA) and subsequently with iminodiacetic acid (IDA). To investigate the application of this material for generating protein profiles of human serum samples, the serum samples were agitated with the derivatized cellulose particles to a suspension and incubated for 2 h at 30 degrees C. After washing, 1 microL of the IDA-Cu(2+)-cellulose suspension was applied directly onto a MALDI-target, mixed with sinapinic acid (SA) and analyzed with MALDI-TOF MS. Consistent serum specific data were obtained from aliquoted samples analyzed several times, indicating the reliability of the method. However, the serum fingerprints obtained proved to be specific for any given serum. The technique presented allows a high enrichment of sample on the developed target leading to a high sensitivity and reproducibility without depletion of albumin and immunoglobulin, and sample elution prior to MS-analysis. The study demonstrates for the first time that derivatized cellulose particles combined with MALDI-TOF MS represent a simple, economical, and rapid approach to generate serum protein profiles for biomarker identification.

Biomarkers↗