Braccio di Ferro: a new haptic workstation for neuromotor rehabilitation.

This technical note describes a new robotic workstation for neurological rehabilitation, shortly named Braccio di Ferro. It has been designed by having in mind the range of forces and the frequency bandwidth that characterize the interaction between a patient and a physical therapist, as well as a number of requirements that we think are essential for allowing a natural haptic interaction: back-driveability, very low friction and inertia, mechanical robustness, the possibility to operate in different planes, and an open software environment, which allows the operator to add new functionalities and design personalized rehabilitation protocols. Braccio di Ferro is an open system and, in the spirit of open source design, is intended to foster the dissemination of robot therapy. Moreover, its combination of features is not present in commercially available systems.

Biomechanical Phenomena↗

Body sway during quiet standing: is it the residual chattering of an intermittent stabilization process?

This paper reviews different approaches for explaining body sway while quiet standing that directly address the instability of the human inverted pendulum. We argue that both stiffness control [Winter, D. A., Patla, A. E., Riedtyk, S., & Ishac, M. (2001). Ankle muscle stiffness in the control of balance during quiet standing. Journal of Neurophysiology, 85, 2630-2633] and continuous feedback control by means of a PID (Proportional, Integral, Derivative) mechanism [Peterka, R. J. (2000). Postural control model interpretation of stabilogram diffusion analysis. Biological Cybernetics, 83, 335-343.] can guarantee asymptotic stability of controlled posture at the expense of unrealistic assumptions: the level of intrinsic muscle stiffness in the former case, and the level of background noise in the latter, which also determines an unrealistic level of jerkiness in the sway. We show that the decomposition of the control action into a slow and a fast component (rambling and trembling, respectively, as proposed by [Zatsiorsky, V. M., & Duarte, M. (1999). Instant equilibrium point and its migration in standing tasks: Rambling and trembling components of the stabilogram. Motor Control, 4, 185-200; Zatsiorsky, V. M., & Duarte, M. (2000). Rambling and trembling in quiet standing. Motor Control, 4, 185-200.]) is useful but must be modified in order to take into account that rambling is not a stable equilibrium trajectory. We address the possibility of a form of stability weaker than asymptotic stability in light of the intermittent stabilization mechanism outlined by [Loram, I. D., & Lakie, M. (2002a). Human balancing of an inverted pendulum: position control by small, ballistic-like, throw and catch movements. Journal of Physiology, 540, 1111-1124.], and propose an indicator of intermittent stabilization that is related to the phase portrait of the human inverted pendulum. This indicator provides a further argument against the plausibility of PID-like control mechanisms. Finally, we draw attention to the sliding mode control theory that provides a useful theoretical framework for formulating realistic intermittent, stabilization models.

Adult↗

Direct measurement of ankle stiffness during quiet standing: implications for control modelling and clinical application.

In this study, we describe a device for the direct measurement of intrinsic ankle stiffness in quiet standing. It consists of a motorised footplate mounted on a force platform. By generating random sequences of step-like disturbances (1 degrees amplitude, 150 ms duration) and measuring the corresponding displacements of the center of pressure in the antero-posterior direction, we obtained torque-rotation patterns after aligning, averaging, and scaling the postural responses. Such patterns were used for estimating the value of the ankle stiffness, which was normalized as a fraction of the critical value. In order to be confident that the measurements addressed the intrinsic ankle stiffness and were not affected in a significant way by the reflex activation of the muscles in response to the test disturbances, we performed the estimates in different ways: least squares estimates with time windows of different widths and an instantaneous estimate at the time in which the angular acceleration vanishes. The statistical analysis showed that there is no significant difference among the different methods of estimate and the inspection of the electromyographic activity in response to the perturbations showed that at least two of the estimates were certainly outside the possible influence of reflex patterns. The intrinsic ankle stiffness was evaluated to be 64+/-8% of the critical stiffness for test disturbances of the order of 1 degrees. We argue that this figure identifies the lower bound of the range of values which characterise normal sway in quiet standing, whereas the upper bound is given by the estimates performed with much smaller test disturbances [1] which yield a higher value: 91+/-23%. The two estimation paradigms (with very small and very large test disturbances, respectively) are complementary also because they behave in a different way as regards the sensitivity to a bias torque: it is close to zero in the Loram & Lakie's paradigm, whereas it is significant in our paradigm. Thus, as the bias grows, it appears that the range of stiffness values is narrowed and is pushed towards the upper bound. There is a clear potential for the clinical application of these methods, in the sense that the identification of the range of stiffness values used by a patient is a measurable index of motor organisation/reorganisation.

Adult↗

The sway-density curve and the underlying postural stabilization process.

The sway-density curve (SDC) is computed by counting, for each time instant, the number of consecutive samples of the statokinesigram falling inside a circle of small radius R. The authors evaluated the sensitivity of the curve to the variation of R and found that in the range 3-5 mm the sensitivity was low, indicating that SDC is a robust descriptor of posturographic patterns. In addition, they investigated the relationship between SDC and the underlying postural stabilization process by decomposing the total ankle torque into three components: a tonic component (over 69 & of the total torque), an elastic torque caused by ankle stiffness (about 19 &), and an anticipatory active torque (about 12 &). The last component, although the smallest in size, is the most critical for the overall stability of the standing posture and appears to be correlated with the SDC curve.

Adult↗

Spot check and recalibration of stabilometric platforms.

The purpose of this paper is to describe a system for the rapid spot check of the accuracy of stabilometric platforms used in clinical posturography and, if needed, for estimating a recalibration matrix. It is based on a simple mechanical device which can be applied to any stabilometric platform; it consists of a ballast and a rotating mass which can generate a spiral-shaped training set of posturographic data. A software package has been developed whose purpose is to estimate a calibration matrix and to provide a figure of merit for the calibrated system. The data analysis is organized into two phases: a preliminary global phase, which uses the covariance matrix of the training set, and a refinement, iterative phase, which exploits the equation of the spiral. The characteristic features of the proposed system are: 1) it uses dynamic, not static loading, 2) loading is not applied manually, 3) it uses distributed, not point loads, 4) there is no need to bolt the system to the platform. Although these features are found, separately, in different prototypes described in the literature, their combination can only be found in the proposed system. Moreover, while most systems in the literature are intended for gait analysis, the proposed one is specifically designed for posturography.

Biomechanical Phenomena↗