PubMed Health⌕ Search

Biomedical subjects

Maurizio Piattelli

Publications and source records attributed to Maurizio Piattelli.

14 recordsLinked to original sources

Maxillary sinus augmentation with different biomaterials: a comparative histologic and histomorphometric study in man.

OBJECTIVE: Rehabilitation of the edentulous posterior maxilla with dental implants can be difficult because of insufficient bone volume caused by pneumatization of the maxillary sinus and crestal bone resorption. Different biomaterials have been used for sinus augmentation. The aim of the study was to compare different materials in maxillary sinus augmentation in man. METHODS: A total of 94 patients participated in this study. Inclusion criteria were maxillary partial (unilateral or bilateral) edentulism involving the premolar/molar areas, and the presence of 3-5-mm crestal bone between the sinus floor and alveolar ridge. A total of 362 implants were inserted. There were 9 biomaterials used in the sinus augmentation procedures. Each patient underwent 1 biopsy after 6 months. A total of 144 specimens were retrieved. RESULTS: None of the 94 patients had complications. All implants were stable, and x-ray examination showed dense bone around the implants. Mean follow-up was 4 years. There were 7 implants that failed. Histologic resultsshowed that almost all the particles of the different biomaterials (i.e., autologous bone, demineralized freeze-dried bone allograft Biocoral [Inoteb, St. Gonnery, France], Bioglass [US Biomaterials, Alachua, FL], Fisiograft [Ghimas, Bologna, Italy], PepGen P-15 [Dentsply Friadent CeraMed, Lakewood, CO], calcium sulfate, Bio-Oss [Geistlich Pharma AG, Wohlhusen, Switzerland], and hydroxyapatite) were surrounded by bone. Some biomaterials were more resorbable than others. Included are the histomorphometry clarified features of the newly formed bone around the different grafted particles. CONCLUSION: All biomaterials examined resulted in being biocompatible and seemed to improve new bone formation in maxillary sinus lift. No signs of inflammation were present. The data are very encouraging because of the high number of successfully treated patients and the good quality of bone found in the retrieved specimens.

Aged↗

Screw vs cement-implant-retained restorations: an experimental study in the beagle. Part 2. Immunohistochemical evaluation of the peri-implant tissues.

Crestal bone loss has been reported to occur around dental implants. Even if the causes of this bone loss are not completely understood, the presence of a microgap between implant and abutment with a possible contamination of the internal portion of the implants has been suggested. The aim of this study was to see if there were differences in the vascular endothelial growth factor (VEGF) expression, microvessel density (MVD), proliferative activity (MIB-1), and inflammatory infiltrate in the soft tissues around implants with screwed and cemented abutments. Sandblasted and acid-etched implants were inserted in the mandibles of 6 Beagle dogs. Ten 3.5- x 10-mm root-form implants were inserted in each mandible. A total of 60 implants (30 with screwed abutments and 30 with cemented abutments) were used. After 12 months, all the bridges were removed and all abutments were checked for mobility. A total of 8 loosened screws (27%) were found in the screwed abutments, whereas no loosening was observed in cemented abutments. A gingival biopsy was performed in 8 implants with cemented abutments, in 8 implants with screwed abutments, and in 8 implants with unscrewed abutments. No statistically significant differences were found in the inflammatory infiltrate and in the MIB-1 among the different groups. No statistically significant difference was found in the MVD between screwed and cemented abutments (P = .2111), whereas there was a statistically significant difference in MVD between screwed and unscrewed abutments (P = .0277) and between cemented and unscrewed abutments (P = .0431). A low intensity of VEGF was prevalent in screwed and in cemented abutments, whereas a high intensity of VEGF was prevalent in unscrewed abutments. These facts could be explained by the effects induced, in the abutments that underwent a screw loosening, by the presence of bacteria inside the hollow portion of the implants or by enhanced reparative processes.

Acid Etching, Dental↗

Histologic and ultrastructural analysis of regenerated bone in maxillary sinus augmentation using a porcine bone-derived biomaterial.

BACKGROUND: The purpose of the present study was the histologic and ultrastructural evaluation of a biomaterial composed of cortical pig bone in the form of granules. METHODS: After maxillary sinus augmentation using this biomaterial, 10 specimens were retrieved after 5 months in 10 patients using this biomaterial. The specimens were processed to be observed under light microscopy (LM) and transmission electron microscopy (TEM). Histomorphometric measurements were presented by means +/- standard deviations. RESULTS: LM showed that most of the particles were surrounded by newly formed bone. In some areas, the osteoid matrix was present; however, mainly compact bone was present at the interface. There was no evidence of an acute inflammatory infiltrate. The newly formed bone was 36% +/- 2.8% and marrow spaces were 38% +/- 1.6%, whereas residual grafted material was 31% +/- 1.6%. Under TEM, all phases of bone formation (osteoid matrix, woven, and lamellar bone) were observed in proximity with the biomaterial particles. The bone-biomaterial interface showed a close contact between the porcine bone particles and the surrounding bone that had mainly features of mature bone with numerous osteocytes. A lamina limitans was sometimes present at this interface. CONCLUSIONS: According to our knowledge, this is the first study presenting data on TEM of a porcine bone-derived biomaterial used in sinus augmentation procedures in humans. Our findings show that this is a biocompatible biomaterial that can be used for maxillary sinus augmentation procedures without interfering with the normal reparative bone processes.

Absorbable Implants↗

Bone remodeling in immediately loaded and unloaded titanium dental implants: a histologic and histomorphometric study in humans.

Remodeling is thought to prevent microdamage accumulation caused by repetitive loading and to increase the fatigue life of bone. The bone remodeling rate (BRR) is the period of time needed for new bone to replace the existing bone and to allow for the adaptation of bone to its environment. BRR is expressed as a percentage or volume of new bone within a specific time period. The aim of the present study was to evaluate bone remodeling events on submerged and immediately loaded dental implants. Twelve patients with edentulous mandibles participated in this study. All patients were rehabilitated with fixed mandibular prostheses, with 10 dental implants per patient. An additional implant was inserted in the most distal posterior mandibular jaw region. In 6 patients, these additional implants were loaded with a fixed provisional prosthesis the same day of the implant surgery and loaded. In the other 6 patients, the additional implants were left submerged and not loaded. After 6 months, all the additional implants were retrieved with a trephine. The percentage of woven and lamellar bone, number of osteoclasts and osteoblasts, and percentage of bone labeled by tetracycline at 0.5 mm and 2 mm from the implant surface were evaluated. The percentage of lamellar bone, number of osteoblasts, and percentage of bone tetracycline labeling was significantly higher in the loaded implants than in the unloaded implants (P =.0001). Also in the loaded implants, the percentage of woven and lamellar bone, number of osteoclasts and osteoblasts, and percentage of bone tetracycline labeling was significantly higher at 0.5 mm than at 2 mm from the implant surface (P =.0001). No such differences were found in unloaded implants (P =.377). In conclusion, we found that (1) loading appeared to stimulate bone remodeling at the interface, (2) a higher percentage of lamellar bone was found in loaded implants, (3) the percentage of bone labeling was higher at the interface of loaded implants, (4) no differences were found in the BRRs between immediately loaded and unloaded implants, and (5) immediate loading had not interfered on the lamellar bone formation at the interface and had not produced formation of woven bone at the interface.

Adult↗

A 16-year study of the microgap between 272 human titanium implants and their abutments.

A microgap has been described at the level of the implant-abutment connection. This microgap can be colonized by bacteria, and this fact could have relevance on the remodeling of the peri-implant crestal bone and on the long-term health of the peri-implant tissues. The authors report on 272 implants with screw- or cement-retained abutments retrieved from humans for different causes during a 16-year period. In the implants with screw-retained abutments, a 60-microm microgap was present at the level of implant-abutment connection. In some areas the titanium had sheared off from the surface and from the internal threads. The contact between the threads of the implant and those of the abutment was limited to a few areas. Bacteria were often present in the microgaps between implant and abutment and in the internal portion of the implants. In implants with cement-retained abutments, a 40-microm microgap was found at the level of the implant-abutment connection. No mechanical damage was observed at the level of the implant or of the abutment. All the internal voids were always completely filled by the cement. No bacteria were observed in the internal portion of the implants or at the level of the microgap. The differences in the size of the microgap between the two groups were statistically significant (P < .05). In conclusion, in screw-retained abutments the microgap can be a critical factor for colonization of bacteria, whereas in cement-retained abutments all the internal spaces were filled by cement. In these retrieved implants, the size of the microgap was markedly variable and much larger than that observed in vitro.

Bacteria↗

Interimplant distance and crestal bone resorption: a histologic study in the canine mandible.

BACKGROUND: Crestal bone loss has been shown to occur around dental implants. This crestal bone resorption may determine a more apical position of the gingival margin. A clear trend of increased bone loss with increased interimplant distance has been reported. PURPOSE: The aim of the present study was to evaluate, in the canine mandible, the crestal bone behavior around dental implants inserted with different interimplant distances. MATERIALS AND METHODS: Sandblasted and acid-etched implants (Bone System, Milano, Italy) were placed in the mandibles of six beagle dogs. Each dog received 10 implants in the mandible (five in the right side and five in the left side). A total of 60 implants was used in this study. The implants were divided in four groups: group I, with a 2 mm interimplant distance; group II, with a 3 mm interimplant distance; group III, with a 4 mm interimplant distance; and group IV, with a 5 mm interimplant distance. The dogs were killed after 12 months. RESULTS: No statistically significant differences were found in regard to vertical bone loss whereas on the contrary, statistically significant differences were found in regard to lateral bone loss (p = .0001). Statistically significant differences also were found in regard to vertical crestal bone loss (p = .0001). In fact vertical crestal bone loss decreased, from 1.98 mm in group I to 0.23 mm in group IV. CONCLUSIONS: The clinical significance of these data lies in the fact that the increased crestal bone loss results in an increase in the distance between the base of the contact points of the neighboring implants and the crest of bone, and this fact could determine whether the papilla is present or absent between two implants.

Alveolar Bone Loss↗

Effect of enamel matrix derivative (Emdogain) on bone defects in rabbit tibias.

The aim of this study was to assess the effect of an enamel matrix derivative (Emdogain, Biora, AB, Malmö, Sweden) on bone healing. Ten New Zealand rabbits, weighing about 2.5 kg, were used. One 8-mm bone defect was created in each tibia. The defect on the right leg was filled with Emdogain, whereas the defect on the opposite leg was left unfilled as control. A total of 20 defects were created. Five rabbits each were killed at 4 and 8 weeks with an overdose of Tanax. Block sections containing the defects were retrieved and the specimens processed for light microscopy examination. The slides were stained with acid and basic fuchsin and toluidine blue. Histologically, no differences were noted in both groups at each observation period; in the test group, remnants of the implanted Emdogain were not present at 4 weeks. Newly formed bone was detectable in both groups at all observation times. At 8 weeks, both groups showed mature bone, and in the test group the material implanted was not visible. No inflammatory cells were visible in both groups. In conclusion, our results indicate that Emdogain implanted in bone defects is fully resorbed after 4 to 8 weeks and does not adversely affect bone formation.

Animals↗

Histologic evaluation of an immediately loaded titanium implant retrieved from a human after 6 months in function.

Clinical and histologic studies have demonstrated that immediate loading can be successfully used in implant dentistry. Many factors are thought to be of importance in obtaining mineralized tissues at the interface. This study describes the implant interface of an immediately loaded implant with a conical implant-abutment connection that had been inserted in the posterior mandible for 6 months. Histology showed that mineralized tissue was present at about 74% +/- 6% of the implant interface. No gaps, fibrous tissue, or inflammatory infiltrate were present at the interface. The bone adjacent to the implant was mainly lamellar (90% +/- 4.5%). Tetracycline was used to label trabecular bone, and labeled bone was found in direct contact with the implant surface. The extensive labelling by tetracycline demonstrated a large quantity of newly formed bone at the implant interface. The distance between the 2 lines marked by tetracycline was 85 +/- 5 mm. The results of this study show that immediately loaded dental implants can form mineralized tissues at the bone-implant interface.

Aged↗

Maxillary sinus augmentation with a synthetic cell-binding peptide: histological and histomorphometrical results in humans.

Bone substitutes should be used when sufficient amounts of autologous bone cannot be harvested from intraoral donor sites. P-15 is a highly conserved linear peptide with a 15 amino acid sequence identical to the sequence contained in the residues 766 to 780 of the alpha-chain of type I collagen. PepGen P-15 (Dentsply Friadent, Mannheim, Germany) is a combination of the mineral component of bovine bone (Osteograf/N 300) with P-15. Bio-Oss (Geistlich, Mannheim, Germany) is a deproteinized sterilized bovine bone with 75% to 80% porosity and a crystal size of approximately 10 microm in the form of cortical granules. The purpose of the present histological and histomorphometrical study was to compare maxillary sinus augmentation procedures in humans performed with PepGen P-15 with procedures associated with Bio-Oss and autologous bone. Seven patients participated in this study (3 men and 4 women; ages between 48 and 69 years, mean of 58 years) and were categorized into 3 groups. In group 1, a mixture of 50% autologous bone from an intraoral source and 50% Bio-Oss was used. In group 2, the graft materials used were 50% Bio-Oss and 50% PepGen P-15. In group 3, 50% autologous bone and 50% PepGen P-15 were used. Group 1 histomorphometry showed that the percentage of newly formed bone was 38.7% +/- 3.2%, marrow spaces represented 45.6% +/- 5%, and residual graft particles constituted the remaining 14.4% +/- 2.1%. Group 2 histomorphometry showed that newly formed bone represented 36.7% +/- 3.3%, marrow spaces represented 39.7% +/- 3.4%, and residual graft particles represented 19.6% +/- 2.1%. In group 3, newly formed bone represented 32.2% +/- 3.2%, marrow spaces represented 38% +/- 2.5%, and residual graft particles represented 28.8% +/- 1.1%. Non-statistically significant differences were found in the percentage of newly formed bone in the different groups (P = .360). Statistically significant differences were found in the percentage of residual graft materials among the different groups (group 1 vs groups 2 and 3) (P = .0001). These data demonstrate that the use of bone-replacement materials, without the addition of autologous bone, could be an alternative in sinus augmentation procedures. Such treatment would increase patient satisfaction, decrease surgical complications, and save the clinician substantial operating time.

Aged↗

Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study.

BACKGROUND: Little is known about the mechanisms of bacterial interaction with implant materials in the oral cavity. A correlation between plaque accumulation and progressive bone loss around implants has been reported. Bacterial adhesion shows a direct positive correlation with surface roughness. Other surface characteristics also seem to be extremely important with regard to plaque formation. Different adhesion affinities of bacteria have been reported for different materials. The aim of this study was to characterize the percentage of surface covered by bacteria on commercially pure titanium and zirconium oxide disks. METHODS: Ten patients participated in this study. A removable acrylic device was adapted to the molar-premolar region, and commercially pure titanium (control) and zirconium oxide (test) disks were glued to the buccal aspect of each device. The surface roughness of titanium and test specimens was similar. After 24 hours, all disks were removed and processed for scanning electron microscopy, for the evaluation of the portion of surface covered by bacteria. RESULTS: In control specimens, the area covered by bacteria was 19.3% +/- 2.9; in test specimens, the area was 12.1% +/- 1.96. The disk surface covered by bacteria on test specimens was significantly lower than that of control specimens (P = 0.0001). CONCLUSION: Our results demonstrate that zirconium oxide may be a suitable material for manufacturing implant abutments with a low colonization potential.

Adult↗

Osseointegration in a sinus augmented with bovine porous bone mineral: histological results in an implant retrieved 4 years after insertion. A case report.

BACKGROUND: A subject of controversy in implant dentistry is what is the most appropriate material for sinus augmentation. Little is known about the healing pattern and the osseointegration processes at the interface of implants placed in different grafting materials in man. Bovine porous bone mineral (BPBM) is a xenogenic material similar to human cancellous bone with a high biocompatibility and osteoconductivity. METHODS: A 50-year-old patient presented a posterior left maxilla with an insufficient bone height for implant insertion. In January 1999, a sinus lifting procedure was performed and the left sinus was augmented with BPBM; in November 1999, three implants were inserted, and in July 2000 a fixed prosthetic restoration was positioned. In June 2003 the connecting screw of the middle implant fractured and it was decided to remove the implant using a 5 mm trephine bur. RESULTS: All BPBM particles were surrounded by newly formed bone. No BPBM particle was in direct contact with the implant surface, and between the implant surface and the particles there was newly-formed bone. BPBM seemed to undergo a very slow resorption; the particles constituted 36% +/- 3% of the peri-implant tissues. The bone-implant contact percentage was 72% +/- 4%. CONCLUSIONS: In our specimens, we found an intimate, direct contact between bone and implant without an interposition of the graft material particles. A very high bone-to-implant contact percentage was present. Our results show that the slow resorption of the graft particles did not jeopardize the osseointegration of the implant.

Animals↗

Bone healing around titanium and titanium nitride-coated dental implants with three surfaces: an experimental study in rats.

BACKGROUND: Titanium nitride (TiN) has been used in many fields as a coating of surgical instruments, with the purpose of creating materials more resistant to wear and corrosion and also reducing adhesion. PURPOSE: The aim of this study was to evaluate the biocompatibility of TiN-coated dental implants. MATERIALS AND METHODS: Forty-five rats were used in this study. One hundred eighty 2 mm x 2 mm implants (P.H.I. San Vittore Olona, Milano, Italy) were used. The implants were divided into the following three groups: Group 1 (n = 60): 30 machined and 30 machined coated with Group 2 (n = 60): 30 sandblasted and 30 sandblasted coated with Group 3 (n = 60): 30 titanium plasma sprayed, 30 titanium plasma sprayed and coated with TiN Four implants were placed in each rat, two implants coated with TiN on the right tibia and two uncoated implants on the left. The animals were killed after 5, 10, 20, 30, or 60 days. Another 18 implants were used for surface roughness analysis. RESULTS: The present study showed that the healing around the TiN-coated implants was similar to that observed around the uncoated surfaces. CONCLUSIONS: TiN coating demonstrated a good biocompatibility, did not have untoward effects on the periimplant bone formation, and did not change the surface roughness values.

Animals↗

Bacterial adhesion on titanium nitride-coated and uncoated implants: an in vivo human study.

Titanium nitride (TiN) has been used in many fields as a surgical instrument coating that makes the surgical materials more resistant to wear and corrosion. The aim of the present study was an in vivo evaluation of the bacterial adhesion to TiN-coated (test) and uncoated (control) titanium implants. Six patients aged between 21 and 25 years and in excellent systemic health participated in the study. All of the participants gave their informed consent. The participants were selected on the basis of good periodontal health and no signs of mouth breathing. In each of the 6 participants, a removable acrylic device was adapted to the molar-premolar region of each quadrant of the jaws. One 4 x 13 mm titanium implant was glued to the buccal aspect of each device. The plasma spray covered 11.5 mm of the body of the implant, whereas the neck was machined titanium. Test implants were glued to the right devices and control implants were glued to the left devices. After 24 hours, the implants were removed from each device and processed for scanning electron microscopy for evaluation of the machined portion of the implant covered by bacteria. A total of 24 implants were used in this study, 12 test and 12 control. Surface characterization of the machined portion of the neck of the implant was performed on an additional 10 implants (5 test and 5 control). On test implants the implant surface covered by bacteria was significantly lower compared with that of control implants (P = .0001). The surface roughness was similar in both groups. TiN surfaces showed a significant reduction of the presence of bacteria, and this fact could probably be important in the decrease of the inflammation of the peri-implant soft tissues.

Adult↗

Bone response to machined and resorbable blast material titanium implants: an experimental study in rabbits.

The aim of the present study was a comparison of implants' responses to a machined surface and to a surface sandblasted with hydroxyapatite (HA) particles (resorbable blast material [RBM]). Threaded machined and RBM, grade 3, commercially pure, titanium, screw-shaped inplants were used in this study. Twenty-four New Zealand white mature male rabbits were used. The inplants were inserted into the articular femoral knee joint according to a previously described technique. Each rabbit received 2 inplants, 1 test (RBM) and 1 control (machined). A total of 48 implants (24 control and 24 test) were inserted. The rabbits were anesthetized with intramuscular injections of fluanisone (0.7 mg/ kg body weight) and diazepam (1.5 mg/kg b.wt.), and local anesthesia was given using 1 mL of 2% lidocaine/adrenalin solution. Two rabbits died in the postoperative course. Four animals were euthanatized with an overdose of intravenous pentobarbital after 1, 2, 3, and 4 weeks; 6 rabbits were euthanatized after 8 weeks. A total of 44 implants were retrieved. The specimens were processed with the Precise 1 Automated System to obtain thin ground sections. A total of 3 slides were obtained for each implant. The slides were stained with acid and basic fuchsin and toluidine blue. The slides were observed in normal transmitted light under a Leitz Laborlux microscope, and histomorphometric analysis was performed. With the machined implants, it was possible to observe the presence of bone trabeculae near the implant surface at low magnification. At higher magnification many actively secreting alkaline phosphatasepositive (ALP+) osteoblasts were observed. In many areas, a not yet mineralized matrix was present. After 4 to 8 weeks, mature bone appeared in direct contact with the implant surface, but in many areas a not yet mineralized osteoid matrix was interposed between the mineralized bone and implant surface. In the RBM implants, many ALP+ osteoblasts were present and in direct contact with the implant surface. In other areas of the implant perimeter it was possible to observe the formation of an osteoid matrix directly on the implant surface. Mature bone with few marrow spaces was present after 4 to 8 weeks. Beginning in the third week, a statistically significant difference (P < .001) was found in the bone-implant contact percentages in machined and RBM implants. It must be stressed that these results have been obtained in a passive, nonloaded situation.

Alkaline Phosphatase↗