PubMed Health⌕ Search

Biomedical subjects

Max A Viergever

Publications and source records attributed to Max A Viergever.

At least 19 recordsLinked to original sources

Noninvasive magnetic resonance to three-dimensional rotational x-ray registration of vertebral bodies for image-guided spine surgery.

STUDY DESIGN: Magnetic resonance (MR) and three-dimensional rotational x-ray (3DRX) images of cadaveric spinal segments were registered using a conventional point-based technique and a noninvasive technique called maximization of mutual information (MMI). OBJECTIVES: To assess the feasibility and accuracy of MMI-based registration in comparison with point-based registration as a new noninvasive image-to-patient registration technique for use in minimally invasive image-guided spine surgery. SUMMARY OF BACKGROUND DATA: In image-guided orthopedic surgery, correspondence between before surgery acquired images and the patient is required. Currently, this necessitates an invasive registration step, in which anatomic landmarks on the bone surface have to be physically touched by a pointer. To overcome this invasive procedure, we propose using a calibrated 3DRX system, a modality that can visualize high contrast objects intraoperatively and that provides a direct correspondence between the image data and the patient. A noninvasive voxel-based technique is used to register the intraoperative 3DRX image to a before surgery acquired MR image. METHODS: Cadaveric thoracic and lumbar spine segments were implanted with markers, which were used as landmarks. The accuracy of the landmark-based registration was compared with MMI-based registration using the residual errors on the marker positions. RESULTS: The errors made using the point-based registration technique were compared with the errors made with MMI. The results show a statistically significant lower error (P < 0.01) for the proposed MMI method. CONCLUSIONS: Noninvasive MMI registration of intraoperative 3DRX images to preoperative MR images is more accurate than point-based registration in cadaveric spine segments. It is therefore a promising technique for replacing the invasive landmark-based registration that is currently used in image-guided spine surgery.

Humans↗

Multiscale vessel tracking.

A method is presented that uses a vectorial multiscale feature image for wave front propagation between two or more user defined points to retrieve the central axis of tubular objects in digital images. Its implicit scale selection mechanism makes the method more robust to overlap and to the presence of adjacent structures than conventional techniques that propagate a wave front over a scalar image representing the maximum of a range of filters. The method is shown to retain its potential to cope with severe stenoses or imaging artifacts and objects with varying widths in simulated and actual two-dimensional angiographic images.

Algorithms↗

Measuring the arterial input function with gradient echo sequences.

The measurement of the arterial input function by use of gradient echo sequences was investigated by in vitro and in vivo experiments. First, calibration curves representing the influence of the concentration of Gd-DTPA on both the phase and the amplitude of the MR signal were measured in human blood by means of a slow-infusion experiment. The results showed a linear increase in the phase velocity and a quadratic increase in DeltaR(*) (2) as a function of the Gd-DTPA concentration. Next, the resultant calibration curves were incorporated in a partial volume correction algorithm for the arterial input function determination. The algorithm was tested in a phantom experiment and was found to substantially improve the accuracy of the concentration measurement. Finally, the reproducibility of the arterial input function measurement was estimated in 16 patients by considering the input function of the left and the right sides as replicate measurements. This in vivo study showed that the reproducibility of the arterial input function determination using gradient echo sequences is improved by employing a partial volume correction algorithm based on the calibration curve for the contrast agent used.

Algorithms↗

On the artifact of a subvoxel susceptibility deviation in spoiled gradient-echo imaging.

In MRI, susceptibility-based negative contrast amplifies the effect of objects that are too small to be detected by water displacement or intrinsic contrast properties. In this work, a simplified description of the susceptibility artifact of a subvoxel object in spoiled gradient-echo imaging is presented that focuses on the elimination of signal in its vicinity: the dephased-volume. The size and position of the dephased-volume are investigated using 3D time-domain simulations and in vitro experiments in which scan parameters and object magnetic moment are systematically varied. Overall signal loss is found to be linearly related to a dephasing parameter that contains the susceptibility difference with tissue, object volume, and echo time (TE), and thus allows the magnetic moment of the object to be assessed. Gradient strength, in-plane resolution, fractional echo, and slice orientation have limited influence. For the settings used, the center of mass of the artifact was always within 0.5 mm of the object's in-plane position.

Artifacts↗

Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRI.

Simulations of dynamic susceptibility contrast (DSC) MRI are frequently performed by assuming a certain shape for the input function and the microvascular response function. However, to investigate the influence of parameters that will affect the shape of the input function, a more complex model of the human vasculature is required. In this study, a model of the human vasculature is proposed that consists of a network of vascular operators based on physiological data typical of a 35-year-old male subject. The simulated contrast passage curves were found to be within the range of observed contrast passage curves in a population of patients without vascular disease. The model was used to predict the effect of different injection speeds of the contrast agent on the accuracy of the perfusion experiment. It was found that injection speeds of <3 ml/s lead to an underestimation of the observed cerebral blood flow (CBF). Additionally, it was determined that decreasing the temporal resolution of the acquisition results in an underestimation of the CBF values, and an increase of the standard deviation (SD) of CBF measurements.

Adult↗

Passive tracking exploiting local signal conservation: the white marker phenomenon.

This article presents a novel approach to passive tracking of paramagnetic markers during endovascular interventions, exploiting positive contrast of the markers to their background, so-called "white marker tracking." The positive contrast results from dephasing of the background signal with a slice gradient, while near the marker the signal is conserved because a dipole field induced by the marker compensates the dephasing gradient. Theoretical investigation shows that a local gradient induced by the local dipole field will nearly always cancel the dephasing gradient somewhere, regardless of marker composition, gradient strength, orientation, and acquisition parameters. The actual appearance of the white marker is determined by the marker strength, echo-time, slice thickness, and gradient strength, as shown both theoretically and experimentally. The novel concept is demonstrated by tracking experiments in a flow phantom and in pig models and is shown to allow reliable and robust depiction of paramagnetic markers with positive contrast and significant suppression of the background signal.

Animals↗

Display of fused images: methods, interpretation, and diagnostic improvements.

The use of integrated visualization for medical images aims at assisting clinicians in the difficult task of mentally translating and integrating medical image data from multiple sources into a three-dimensional (3D) representation of the patient. This interpretation of the enormous amount and complexity of contemporary, multiparameter, and multimodal image data demands efficient methods for integrated presentation. This article reviews methods for fused display with the main focus on integration of functional with anatomical images. First, an overview of integrated two-dimensional (2D) and 3D medical image display techniques is presented, and topics related to the interpretation of the integrated images are discussed. Then we address the key issue for clinical acceptance, ie, whether these novel visualization techniques lead to diagnostic improvements. Methods for fused display appear to be powerful tools to assist the clinician in the retrieval of relevant information from multivariate medical image data. Evaluation of the different methods for fused display indicates that the diagnostic process improves, notably as concerns the anatomical localization (typically of functional processes), the registration procedure, enhancement of signal, and efficiency of information presentation (which increases speed of interpretation and comprehension). Consequently, fused display improves communication with referring specialists, increases confidence in the observations, and facilitates the intra- and intersubject comparison of a large part of the data from the different sources, thereby simplifying the extraction of additional, valuable information. In most diagnostic tasks the clinician is served best by providing several (interactive and flexible) 2D and 3D methods for fused display for a thorough assessment of the wealth of image information from multiple sources.

Anatomy, Cross-Sectional↗

Localization and segmentation of aortic endografts using marker detection.

A method for localization and segmentation of bifurcated aortic endografts in computed tomographic angiography (CTA) images is presented. The graft position is determined by detecting radiopaque markers sewn on the outside of the graft. The user indicates the first and the last marker, whereupon the remaining markers are automatically detected. This is achieved by first detecting marker-like structures through second-order scaled derivative analysis, which is combined with prior knowledge of graft shape and marker configuration. The identified marker centers approximate the graft sides and, derived from these, the central axis. The graft boundary is determined by maximizing the local gradient in the radial direction along a deformable contour passing through both sides. Three segmentation methods were tested. The first performs graft contour detection in the initial CT-slices, the second in slices that were reformatted to be orthogonal to the approximated graft axis, and the third uses the segmentation from the second method to find a more reliable approximation of the axis and subsequently performs contour detection. The methods have been applied to ten CTA images and the results were compared to manual marker indication by one observer and region growing aided segmentation by three observers. Out of a total of 266 markers, 262 were detected. Adequate approximations of the graft sides were obtained in all cases. The best segmentation results were obtained using a second iteration orthogonal to the axis determined from the first segmentation, yielding an average relative volume of overlap with the expert segmentations of 92%, while the interexpert reproducibility is 95%. The averaged difference in volume measured by the automated method and by the experts equals the difference among the experts: 3.5%.

Anatomy, Cross-Sectional↗

Blood pool contrast-enhanced MRA: improved arterial visualization in the steady state.

Blood pool agents (BPAs) for contrast-enhanced magnetic resonance angiography (CE-MRA) allow prolonged imaging during the steady state when the agent is distributed through the complete vascular system. This increases both the spatial resolution and the contrast resolution. However, simultaneous venous and arterial enhancement hampers interpretation. For the pelvic region of the vasculature, it is shown that arterial visualization in this equilibrium phase can be improved if the central arterial axis (CAA) is known. However, manually obtaining this axis is not feasible in clinical practice. Therefore, a method is presented that utilizes images acquired during the first pass of the contrast agent to find the CAA in the steady-state data with minimum user initialization. The accuracy of the resulting CAA is compared with tracings of three observers in six patient datasets. It was found that the mean difference between the semiautomatic method and the manual delineation is 1.32 mm in the steady-state data, and that the resulting CAA was always within the arterial lumen, which is an important prerequisite for both improved visualization and segmentation.

Algorithms↗

Mutual-information-based registration of medical images: a survey.

An overview is presented of the medical image processing literature on mutual-information-based registration. The aim of the survey is threefold: an introduction for those new to the field, an overview for those working in the field, and a reference for those searching for literature on a specific application. Methods are classified according to the different aspects of mutual-information-based registration. The main division is in aspects of the methodology and of the application. The part on methodology describes choices made on facets such as preprocessing of images, gray value interpolation, optimization, adaptations to the mutual information measure, and different types of geometrical transformations. The part on applications is a reference of the literature available on different modalities, on interpatient registration and on different anatomical objects. Comparison studies including mutual information are also considered. The paper starts with a description of entropy and mutual information and it closes with a discussion on past achievements and some future challenges.

Algorithms↗

Guide-wire tracking during endovascular interventions.

A method is presented to extract and track the position of a guide wire during endovascular interventions under X-ray fluoroscopy. The method can be used to improve guide-wire visualization in low-quality fluoroscopic images and to estimate the position of the guide wire in world coordinates. A two-step procedure is utilized to track the guide wire in subsequent frames. First, a rough estimate of the displacement is obtained using a template-matching procedure. Subsequently, the position of the guide wire is determined by fitting a spline to a feature image. The feature images that have been considered enhance line-like structures on: 1) the original images; 2) subtraction images; and 3) preprocessed images in which coherent structures are enhanced. In the optimization step, the influence of the scale at which the feature is calculated and the additional value of using directional information is investigated. The method is evaluated on 267 frames from ten clinical image sequences. Using the automatic method, the guide wire could be tracked in 96% of the frames, with a similar accuracy to three observers, although the position of the tip was estimated less accurately.

Algorithms↗

Level-set-based artery-vein separation in blood pool agent CE-MR angiograms.

Blood pool agents (BPAs) for contrast-enhanced (CE) magnetic-resonance angiography (MRA) allow prolonged imaging times for higher contrast and resolution. Imaging is performed during the steady state when the contrast agent is distributed through the complete vascular system. However, simultaneous venous and arterial enhancement in this steady state hampers interpretation. In order to improve visualization of the arteries and veins from steady-state BPA data, a semiautomated method for artery-vein separation is presented. In this method, the central arterial axis and central venous axis are used as initializations for two surfaces that simultaneously evolve in order to capture the arterial and venous parts of the vasculature using the level-set framework. Since arteries and veins can be in close proximity of each other, leakage from the evolving arterial (venous) surface into the venous (arterial) part of the vasculature is inevitable. In these situations, voxels are labeled arterial or venous based on the arrival time of the respective surface. The evolution is steered by external forces related to feature images derived from the image data and by internal forces related to the geometry of the level sets. In this paper, the robustness and accuracy of three external forces (based on image intensity, image gradient, and vessel-enhancement filtering) and combinations of them are investigated and tested on seven patient datasets. To this end, results with the level-set-based segmentation are compared to the reference-standard manually obtained segmentations. Best results are achieved by applying a combination of intensity- and gradient-based forces and a smoothness constraint based on the curvature of the surface. By applying this combination to the seven datasets, it is shown that, with minimal user interaction, artery-vein separation for improved arterial and venous visualization in BPA CE-MRA can be achieved.

Algorithms↗

Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature.

Using three-dimensional rotational X-ray angiography (3DRA), three-dimensional (3-D) information of the vasculature can be obtained prior to endovascular interventions. However, during interventions, the radiologist has to rely on fluoroscopy images to manipulate the guide wire. In order to take full advantage of the 3-D information from 3DRA data during endovascular interventions, a method is presented that yields an integrated display of the position of the guide wire and vasculature in 3-D. The method relies on an automated method that tracks the guide wire simultaneously in biplane fluoroscopy images. Based on the calibrated geometry of the C-arm, the 3-D guide-wire position is determined and visualized in the 3-D coordinate system of the vasculature. The method is evaluated in an intracranial anthropomorphic vascular phantom. The influence of the angle between projections, distortion correction of the projection images, and accuracy of geometry knowledge on the accuracy of 3-D guide-wire reconstruction from biplane images is determined. If the calibrated geometry information is used and the images are corrected for distortion, a mean distance to the reference standard of 0.42 mm and a tip distance of 0.65 mm is found, which means that accurate guide-wire reconstruction from biplane images can be performed.

Algorithms↗

Computer-aided diagnosis in high resolution CT of the lungs.

A computer-aided diagnosis (CAD) system is presented to automatically distinguish normal from abnormal tissue in high-resolution CT chest scans acquired during daily clinical practice. From high-resolution computed tomography scans of 116 patients, 657 regions of interest are extracted that are to be classified as displaying either normal or abnormal lung tissue. A principled texture analysis approach is used, extracting features to describe local image structure by means of a multi-scale filter bank. The use of various classifiers and feature subsets is compared and results are evaluated with ROC analysis. Performance of the system is shown to approach that of two expert radiologists in diagnosing the local regions of interest, with an area under the ROC curve of 0.862 for the CAD scheme versus 0.877 and 0.893 for the radiologists.

Algorithms↗

Underestimation of access flow by ultrasound dilution flow measurements.

For hemodialysis access surveillance, flow measurements are increasingly considered important because they identify accesses at risk of thrombosis. Usually these flow measurements are performed with the ultrasound dilution technique. In a previous patient study it was observed that the resulting flow values were systematically low as compared to magnetic resonance flow measurements, but a satisfactory explanation was lacking. In the present study, we will demonstrate by hemodynamic calculations and in vitro experiments that this discrepancy can be explained by a temporary reduction of the access flow rate, caused by the reversed needle configuration during ultrasound dilution flow measurements. In this configuration. blood is injected retrogressively at one needle and flow between the needles is increased, causing an increased dissipation of energy. The proposed explanation is subsequently confirmed in a patient with a loop graft, by measuring the blood velocity by Doppler ultrasound as a function of reversed dialyzer flow rate. Apart from the ultrasound dilution technique, these findings are applicable to other recently proposed methods for measuring access flow that employ the reversed needle configuration.

Biophysics↗

Improved lumen visualization in metallic vascular implants by reducing RF artifacts.

In this study, a method is proposed for MRI of the lumen of metallic vascular implants, like stents or vena cava filters. The method is based on the reduction of artifacts caused by flow, susceptibility, and RF eddy currents. Whereas both flow artifacts and susceptibility artifacts are well understood and documented, RF artifacts are not. Therefore, the present study comprises an in-depth theoretical explanation of the factors governing the severity of these RF artifacts. It is explained that the RF caging inside cage-like implants is caused by disturbances of the send and receive sensitivities due to coupling between the loops in the implant and the MR scanner's send and receive coils. A scaled excitation angle model describing the behavior of the signal intensity inside the implants as a function of the applied nominal excitation angle is introduced. This theoretical model was validated in phantom experiments. Reduced signal from within implants due to the caging problem could be restored by increasing the applied RF power in the excitation pulse, without exceeding the generally accepted SAR safety limits. The method was tested in vitro and in vivo in a pig model and allowed adequate depiction of the interior of a nitinol stent and that of a vena cava filter in contrast-enhanced MR angiograms. Magn Reson Med 47:171-180, 2002.

Alloys↗

3D MRA coronary axis determination using a minimum cost path approach.

A method is introduced to automatically find the coronary axis based on two or more user-defined points, even in the presence of a severe stenosis. The coronary axis is determined by finding a minimum cost path (MCP) in a feature image in which the tubular-like structures are enhanced. The results of the proposed method were compared with manually drawn central axes to estimate the accuracy. In 32 3D TFE-EPI acquisitions of patients and volunteers, 14 right coronary arteries (RCAs), 15 left anterior descending arteries (LADs), and eight left circumflex arteries (LCXs) were manually tracked twice by two operators to determine a reference axis and to assess the inter- and intra-user variability. On average, the maximum distance to the reference axis, based on only two user-defined points, is less than 1.5 mm; the average distance is around 0.65 mm, which is less than the average in-plane resolution. The results of the method are comparable to those of the manual operators.

Coronary Stenosis↗

Automatic detection of abnormalities in chest radiographs using local texture analysis.

A fully automatic method is presented to detect abnormalities in frontal chest radiographs which are aggregated into an overall abnormality score. The method is aimed at finding abnormal signs of a diffuse textural nature, such as they are encountered in mass chest screening against tuberculosis (TB). The scheme starts with automatic segmentation of the lung fields, using active shape models. The segmentation is used to subdivide the lung fields into overlapping regions of various sizes. Texture features are extracted from each region, using the moments of responses to a multiscale filter bank. Additional "difference features" are obtained by subtracting feature vectors from corresponding regions in the left and right lung fields. A separate training set is constructed for each region. All regions are classified by voting among the k nearest neighbors, with leave-one-out. Next, the classification results of each region are combined, using a weighted multiplier in which regions with higher classification reliability weigh more heavily. This produces an abnormality score for each image. The method is evaluated on two databases. The first database was collected from a TB mass chest screening program, from which 147 images with textural abnormalities and 241 normal images were selected. Although this database contains many subtle abnormalities, the classification has a sensitivity of 0.86 at a specificity of 0.50 and an area under the receiver operating characteristic (ROC) curve of 0.820. The second database consist of 100 normal images and 100 abnormal images with interstitial disease. For this database, the results were a sensitivity of 0.97 at a specificity of 0.90 and an area under the ROC curve of 0.986.

Algorithms↗